Abstract

For neutron radiation and mixed neutron/photon radiation fields, only a few types of direct reading dosemeters are commercially available or under development. Some important features of these dosemeters are briefly outlined and their energy dependent dose equivalent response and suitability for operational monitoring tasks in nuclear facilities, in particular, are discussed.

Abstract

Für Neutronenstrahlung bzw. gemischte Neutronen-/Photonenstrahlungsfelder werden einige wenige direkt anzeigende Dosimeter kommerziell angeboten oder befinden sich im Stadium der Entwicklung. Diese Dosimeter und ihre Funktionsweise werden kurz vorgestellt. Unter besonderer Berücksichtigung ihres energieabhängigen Ansprechvermögens wird die Eignung der Dosimeter für die betriebliche Überwachung in kerntechnischen Anlagen diskutiert.

References

1 International Commission on Radiological Protection: ICRP Publication 74, Annals of the ICRP 26, Nr. 3–4, Pergamon Press, Oxford (1996)Search in Google Scholar

2 Luszik-Bhadra, M.; Rimpler, A.: Stand und Perspektiven elektronischer Personendosimeter für Neutronen/Photonenstrahlungsfelder. Contribution to FS Jahrestagung, Kloster Seeon, Germany, 21–25 April 2002 (TÜV-VerlagSearch in Google Scholar

3 Luszik-Bhadra, M.; Derdau, D.; Hallfarth, G.; Matzke, M.; Wiegel, B.; Wittstock, J.: Measurement of energy and directional distribution of neutron fluence inside a nuclear power plant. Nucl. Instr. Meth. in Phys. Research A 476 (2003) 45710.1016/S0168-9002(01)01490-5Search in Google Scholar

4 Siemens Plc. 2000: Neutron sensitive electronic personal dosemeter (EPD-N Mk2.0). In: Technical Handbook (2000)Search in Google Scholar

5 Aoyama, K.; Nagase, Y.; Suzuki, T.; Watanabe, S.; Taniguchi, K.; Muramatsu, K.; Fujita, M.; Fujii, Y.: The development of new generation electronic personal dosimeters. In: Proceedings of IRPA-10, 10th International Congress of the International Radiation Protection Association, CD-ROM, IRPA, Hiroshima (2000)Search in Google Scholar

6 Alberts, W. G.; Dietz, E.; Guldbakke, S.; Kluge, H.: Response of an electronic personal neutron dosemeter. Radiat. Prot. Dosim. 51 (1994) 20710.1093/oxfordjournals.rpd.a082137Search in Google Scholar

7 Siemens Plc. 2002: Electronic personal dosemeter for neutrons and photons EPD-N2. In Technical Handbook (2002)Search in Google Scholar

8 Luszik-Bhadra, M.; Coleman, J.; Schlegel, D.; Zimbal, A.: Active neutron / photon dosemeters. Contribution to European IRPACongress 2002, Florenz, Italy, 8–11 Oct. 2002, CD-ROMSearch in Google Scholar

9 Lahaye, T.; Cutarella, D.; Ménard, S.; Bolognese-Milsztajn, T.: The first operational dosemeter for neutrons which complies with IEC standard 1323. Radiat. Prot. Dosim. 96 (2001) 24110.1093/oxfordjournals.rpd.a006592Search in Google Scholar

10 d’Errico, F.; Luszik-Bhadra, M.; Lahaye, T.: State of the Art of Electronic Personal Dosimeters for Neutrons. Nuclear Instr. Meth. in Phys. Research A 505 (2003) 41110.1016/S0168-9002(03)01110-0Search in Google Scholar

11 Luszik-Bhadra, M.: A prototype personal neutron dosemeter with one silicon diode. Radiat. Prot. Dosim. 96 (2001) 22710.1093/oxfordjournals.rpd.a006588Search in Google Scholar PubMed

12 Luszik-Bhadra, M.: Individual monitoring in mixed neutron/photon fields using a single silicon detector. Radiat. Prot. Dosim. 101 (2002) 17910.1093/oxfordjournals.rpd.a005962Search in Google Scholar PubMed

13 Wielunski, M.: private communicationSearch in Google Scholar

14 Fiechtner, A.; Wernli, C.; Kahilainen, J.: A prototype personal neutron dosemeter based on an ion chamber and direct ion storage. Radiat. Prot. Dosim. 96 (2001) 26910.1093/oxfordjournals.rpd.a006598Search in Google Scholar PubMed

15 Alberts, W. G.; Alexandre, P.; Arend, E.; d’Errico, F.; Fiechtner, A.; Roos, H.; Schuhmacher, H.; Wernli, C.; Wimmer, S.: Development of electronic personal neutron dosemeters: A European cooperation. Radiat. Prot. Dosim. 96 (2001) 25110.1093/oxfordjournals.rpd.a006594Search in Google Scholar PubMed

16 Roos, H.: private communicationSearch in Google Scholar

17 Ménard, S.; Cutarella, D.; Lahaye, T.; Bolognese-Milsztajn, T.: An active personal neutron dosemeter based on microdosimetric principles: CIME. Radiat. Prot. Dosim. 96 (2001), 26510.1093/oxfordjournals.rpd.a006597Search in Google Scholar PubMed

18 d’Errico, F.; Apfel, R. E.; Curzio, G.; Nath, R.: Electronic neutron personal dosimetry with superheated drop detectors. Radiat. Prot. Dosim. 96 (2001) 26110.1093/oxfordjournals.rpd.a006596Search in Google Scholar PubMed

Received: 2003-02-19
Published Online: 2022-03-11

© 2003 Carl Hanser Verlag, München

Articles in the same Issue

  1. Frontmatter
  2. Calendar of events · veranstaltungskalender
  3. Summaries/Kurzfassungen
  4. Editorial
  5. Radiation Protection: measuring and modeling
  6. Modeling, simulation and measurement of radiation exposure using electronic personal dosimeters on realistic and ICRU phantoms
  7. Books · Bücher
  8. Emerging systemic risks in the 21th century
  9. Status and prospects of electronic personal dosemeters for neutron/photon radiation fields
  10. Mathematical efficiency calibration in gamma spectroscopy
  11. Note · Mitteilung
  12. Karl-Wirtz-Preis der Kerntechnischen Gesellschaft e.V
  13. Recent trends in radioanalytical purification procedures and application to decommissioning of nuclear facilities
  14. Migration of iodine-129 and iodine-127 in soils
  15. Uncertainties of measurements in radiation protection
  16. The response of various neutron dose meters considering the application at a high energy particle accelerator
  17. Books · Bücher
  18. Grundkurs Strahlenschutz Praxiswissen für den Umgang mit radioaktiven Stoffen
  19. Application of modern radiochemical techniques to the determination of Sr-89/Sr-90 in environmental samples
  20. Books · Bücher
  21. Indemnification of Nuclear Damage in the Event of a Nuclear Accident
  22. Influence of calcium on the uptake of ingested strontium
  23. Books · Bücher
  24. Utilisation and Reliability of High Power Proton Accelerators
  25. Area dose measurements by thermoluminescence dosemeters for environmental monitoring
  26. Technical Note
  27. Some comments on Herndon’s nuclear georeactor
  28. Advances · Patente
  29. Patent
  30. Books · Bücher
  31. Possible Implication of Draft ICRP Recommendations
Downloaded on 25.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/kern-2003-0066/html
Scroll to top button