Startseite Advancing magnetometer calibration: a sequential tri-axis approach
Artikel
Lizenziert
Nicht lizenziert Erfordert eine Authentifizierung

Advancing magnetometer calibration: a sequential tri-axis approach

  • Omidreza Daneshmandi , Iman Hosseini ORCID logo EMAIL logo , Arsalan Dabbagh , Iman Dehbozorgi , Ali Hosseinzadeh und Zahra Mehrmohammadi
Veröffentlicht/Copyright: 28. Januar 2025
Veröffentlichen auch Sie bei De Gruyter Brill

Abstract

This paper presents a comparative study on the calibration of magnetometer sensors, focusing on three methods: the least square method, the ellipsoid fitting method, and a proposed sequential method. The effectiveness of the first two methods is investigated, and their results are compared with the outcomes achieved through the application of the sequential method. Practical data is utilized to demonstrate the advantages of the proposed method. Through this research, insights are provided into the performance and limitations of the least square and ellipsoid fitting methods, while highlighting the superior capabilities of the sequential method. The results show that the sequential method inherits the capabilities of both method and leads to a more reliable calibration.


Corresponding author: Iman Hosseini, Hydro-Aeronautical Research Center, Shiraz University, Shiraz, Iran, E-mail: 

  1. Research ethics: Not applicable.

  2. Informed consent: Informed consent was obtained from all individuals included in this study, or their legal guardians or wards.

  3. Author contributions: The authors have accepted responsibility for the entire content of this manuscript and approved its submission.

  4. Use of Large Language Models, AI and Machine Learning Tools: We have used chatgpt to improve language.

  5. Conflict of interest: The authors state no conflict of interest.

  6. Research funding: None declared.

  7. Data availability: Not applicable.

References

1. Cao, H, Wang, Y, Bi, J, Qi, H, Sun, M. Robust heading estimation algorithm for android smartphones. IEEE Trans Instrum Meas 2023;72:1–11. https://doi.org/10.1109/TIM.2023.3238760.Suche in Google Scholar

2. Zhu, K, Deng, F, Zhang, C, Kang, H, Wen, Z, Guo, G. A multi-source fusion navigation system to overcome gps interruption of unmanned ground vehicles. IEEE Access 2023;11:61070–81. https://doi.org/10.1109/access.2023.3282219.Suche in Google Scholar

3. Gnadt, A. Machine learning-enhanced magnetic calibration for airborne magnetic anomaly navigation. In: AIAA SciTech 2022 forum; 2022:1760 p.10.2514/6.2022-1760Suche in Google Scholar

4. Mirzaei, M, Hosseini, I, Makarem, H. Attitude determination improvement in accelerated motions for maneuvering underwater vehicles. Appl Ocean Res 2020;104:102355. https://doi.org/10.1016/j.apor.2020.102355.Suche in Google Scholar

5. Hosseini, I, Mirzaei, M, Asemani, MH. Nonlinear output feedback for hl-20 flight control using back-stepping observer. J Intell Rob Syst 2020;100:1401–16. https://doi.org/10.1007/s10846-020-01251-8.Suche in Google Scholar

6. Du, WY. Resistive, capacitive, inductive, and magnetic sensor technologies. Boca Raton, FL: CRC Press; 2014.10.1201/b17685Suche in Google Scholar

7. Guo, P, Qiu, H, Yang, Y, Ren, Z. The soft iron and hard iron calibration method using extended kalman filter for attitude and heading reference system. In: 2008 IEEE/ION position, location and navigation symposium. IEEE; 2008:1167–74 pp.10.1109/PLANS.2008.4570003Suche in Google Scholar

8. Chen, W, Li, X, Zhang, H, Jia, P, Zou, F, Lyu, W, et al.. A heading correction technology based on magnetometer calibration and adaptive anti-interference algorithm. Sensor Actuator Phys 2023;363:114726. https://doi.org/10.1016/j.sna.2023.114726.Suche in Google Scholar

9. Crassidis, JL, Lai, K-L, Harman, RR. Real-time attitude-independent three-axis magnetometer calibration. J Guid Control Dynam 2005;28:115–20. https://doi.org/10.2514/1.6278.Suche in Google Scholar

10. Zikmund, A, Janosek, M, Ulvr, M, Kupec, J. Precise calibration method for triaxial magnetometers not requiring earth’s field compensation. IEEE Trans Instrum Meas 2015;64:1242–7. https://doi.org/10.1109/tim.2015.2395531.Suche in Google Scholar

11. Huang, J, Zheng, Z, Zhou, Y, Wang, C, Xu, G, Zha, B. Nonlinear calibration model of a triple axis tunnel magneto resistance magnetometer. IEEE Sensor J 2023;23:28706–13. https://doi.org/10.1109/JSEN.2023.3311988.Suche in Google Scholar

12. Guan, B, Gao, Y, Wang, C-B, Wu, M. Online magnetic deviation calibration method based on recursive least square algorithm. Zhongguo Guanxing Jishu Xuebao. J Chin Inert Technol 2012:20:69–73.Suche in Google Scholar

13. Güder, M, Yılmaz, CN, Altaş, İA. Development of magnetometer calibration algorithm with least squares method and performance analysis. In: 2021 6th international conference on computer science and engineering (UBMK). IEEE; 2021:757–62 pp.10.1109/UBMK52708.2021.9558883Suche in Google Scholar

14. Ammann, N, Derksen, A, Heck, C. A novel magnetometer-accelerometer calibration based on a least squares approach. In: 2015 international conference on unmanned aircraft systems (ICUAS). IEEE; 2015:577–85 pp.10.1109/ICUAS.2015.7152338Suche in Google Scholar

15. Alonso, R, Shuster, MD. Attitude-independent magnetometer-bias determination: a survey. J Astronaut Sci 2002;50:453–75. https://doi.org/10.1007/bf03546248.Suche in Google Scholar

16. Alonso, R, Shuster, MD. Twostep: a fast robust algorithm for attitude-independent magnetometer-bias determination. J Astronaut Sci 2002;50:433–51. https://doi.org/10.1007/bf03546247.Suche in Google Scholar

17. Alonso, R, Shuster, MD. Complete linear attitude-independent magnetometer calibration. J Astronaut Sci 2002;50:477–90. https://doi.org/10.1007/bf03546249.Suche in Google Scholar

18. Batista, DS, Granziera, F, Tosin, MC, Melo, LF. Attitude-independent magnetometer calibration using non-linear least square. IEEE Sensor J 2023;23:14002–16. https://doi.org/10.1109/jsen.2023.3274495.Suche in Google Scholar

19. Gang, Y, Yingtang, Z, Hongbo, F, Guoquan, R, Zhining, L. One-step calibration of magnetic gradient tensor system with nonlinear least square method. Sensor Actuator Phys 2015;229:77–85. https://doi.org/10.1016/j.sna.2015.03.026.Suche in Google Scholar

20. Vasconcelos, JF, Elkaim, G, Silvestre, C, Oliveira, P, Cardeira, B. Geometric approach to strapdown magnetometer calibration in sensor frame. IEEE Trans Aero Electron Syst 2011;47:1293–306. https://doi.org/10.1109/taes.2011.5751259.Suche in Google Scholar

21. Renaudin, V, Afzal, MH, Lachapelle, G. Complete triaxis magnetometer calibration in the magnetic domain. J Sens 2010;2010:1–10. https://doi.org/10.1155/2010/967245.Suche in Google Scholar

22. Gebre-Egziabher, D, Elkaim, GH, David Powell, J, Parkinson, BW. Calibration of strapdown magnetometers in magnetic field domain. J Aero Eng 2006;19:87–102. https://doi.org/10.1061/(asce)0893-1321(2006)19:2(87).10.1061/(ASCE)0893-1321(2006)19:2(87)Suche in Google Scholar

23. Shakerian, A, Bilel, S, Landry, RJ. Calibration of 3-axis low-cost magnetometer using the least square ellipsoid fitting algorithm. Int J Sens Sens Netw 2023;11:18–24. https://doi.org/10.11648/j.ijssn.20231101.13.Suche in Google Scholar

24. Feng, W, Liu, S, Liu, S, Yang, S. A calibration method of three-axis magnetic sensor based on ellipsoid fitting. J Inf Comput Sci 2013;10:1551–8.10.12733/jics20101833Suche in Google Scholar

25. Mirzaei, M, Hosseini, I, Babaei, R. Mems magnetometer calibration using modified ellipsoid fitting method. In: 16th international conference of iranian aerospace society; 2017.Suche in Google Scholar

26. Mirzaei, M, Hosseini, I. Robust ellipsoid fitting method based on optimization of a novel nonlinear cost function in navigation systems. J Braz Soc Mech Sci Eng 2019;41:1–9. https://doi.org/10.1007/s40430-019-1747-2.Suche in Google Scholar

27. Hu, F, Wu, Y, Yu, Y, Nie, J, Li, W, Gao, Q. An improved method for the magnetometer calibration based on ellipsoid fitting. In: 2019 12th international congress on image and signal processing, biomedical engineering and informatics (CISP-BMEI). IEEE; 2019:1–5 pp.10.1109/CISP-BMEI48845.2019.8965821Suche in Google Scholar

28. Chi, C, Lv, J-W, Wang, D. Calibration of triaxial magnetometer with ellipsoid fitting method. IOP Conf Ser Earth Environ Sci 2019;237:032015. https://doi.org/10.1088/1755-1315/237/3/032015.Suche in Google Scholar

29. Papafotis, K, Nikitas, D, Sotiriadis, PP. Magnetic field sensors’ calibration: algorithms’ overview and comparison. Sensors 2021;21:5288. https://doi.org/10.3390/s21165288.Suche in Google Scholar PubMed PubMed Central

Received: 2024-06-23
Accepted: 2025-01-01
Published Online: 2025-01-28
Published in Print: 2025-10-27

© 2025 Walter de Gruyter GmbH, Berlin/Boston

Artikel in diesem Heft

  1. Frontmatter
  2. Review
  3. Research using GNSS (Global Navigation Satellite System) products – a comprehensive literature review
  4. Original Research Articles
  5. Impact of baseline length on uncertainty in static relative GNSS positioning
  6. Advancing magnetometer calibration: a sequential tri-axis approach
  7. Application of GNSS-levelling for updating the base vertical network
  8. Spatiotemporal postseismic deformation due to the 2018 Palu-Donggala earthquake revealed the relative importance of viscoelastic relaxation and the afterslip distribution estimated from geodetic observations
  9. Evaluation of PPP software performance for TEC estimation using IRI-2020, CODE, COSMIC, and SWARM with GNSS data
  10. Evaluation of mobile mapping point clouds in the context of height difference estimation
  11. Automated gap and flush measurements between car parts assisted by a highly flexible and accurate robot system
  12. Comprehensive statistical analysis of scintillations on L-band signals from six GNSS constellations over low-latitude region
  13. Recent estimates of crustal deformation and land subsidence in the Nile Delta, Egypt using GNSS-PPP datasets over 2012–2024
  14. Influence of orbit and clock file diversity on GNSS ambiguity resolution
  15. The usefulness of the MAFA method for smartphone precise positioning
  16. Comparative analysis of pseudorange multipath mitigation performance using K-means and Fuzzy c-means clustering techniques
  17. Estimation of GPS-based ionospheric indices by GIX, SIDX, and ROTI during the St. Patrick’s Day geomagnetic storm event in the Indian low latitude region
  18. Post-midnight impact of ionospheric irregularities on GPS based kinematic precise point positioning
Heruntergeladen am 30.11.2025 von https://www.degruyterbrill.com/document/doi/10.1515/jag-2024-0055/html?lang=de
Button zum nach oben scrollen