  • Yong Zhang EMAIL logo , Yao Fang , Baosheng Jin , Youwei Zhang , Chunlei Zhou und Farooq Sher
Veröffentlicht/Copyright: 14. Februar 2019
Veröffentlichen auch Sie bei De Gruyter Brill

Abstract

Numerical investigations of an anti-corrosion design and the combustion process (original conditions and optimal conditions) were conducted for a 660 MW opposed wall fired boiler. In order to solve high-temperature corrosion of the side wall, a scheme was proposed: slotting in the side wall and introducing air (closing-to-wall air) from the secondary air. The effect of anti-corrosion was disclosed in detail by varying the structures of slotting, gas velocities from nozzles and jet inclination angles. The temperature and NOx distribution in the furnace at optimized conditions were compared with those at the original operating conditions. Simulation results showed that the structures of the slot and gas velocities from the nozzles had a marked effect on anti-corrosion of the side wall. When the gas velocity was 4 m/s, an inclination angle of the gas velocity was not conducive to anti-corrosion of the side wall. When the gas velocity increased at the middle and bottom of the side wall, the anti-corrosion effect increased significantly. When the optimal scheme was adopted, the corrosion area of the side wall decreased obviously, but the furnace temperature and the NOx emission increased slightly. The detailed results of this work promote a full understanding of closing-to-wall air and could help to reduce the corrosive area in pulverized-coal furnaces or boilers.

Acknowledgements

The authors gratefully acknowledge financial support from the National Key Research and Development Program of China (Grant No. 2018YFB0605102), A Foundation for the Author of National Excellent Doctoral Dissertation of PR China (201440) and the Fundamental Research Funds for the Central Universities.

References

Belosevic, Srdjan, Vladimir Beljanski, Ivan Tomanovic, Nenad Crnomarkovic, and Dragan Tucakovic. 2012. “Numerical Analysis of NOx Control by Combustion Modifications in Pulverized Coal Utility Boiler.” Energy Fuels 26(1): 425–42.10.1021/ef201380zSuche in Google Scholar

Chen, T., Y. Lu, J. Liu, Q. Huang, G. Chen, B. Jin, and Z. Yong. 2015. “Numerical Simulation on the Optimization of Closing-To-Wall Air in a 660 MW Front and Rear Wall Opposed Coal-Fired Boiler.” Proceedings of the Csee 35 (20): 5265–5271.Suche in Google Scholar

Han, K. H., L. U. Chun-Mei, L. I. Guan-Peng, and J. Liu. 2004. “Current Situation and Discussion about Preventive Measure to the High Temperature Corrosion of Water-Wall Tubes in Large Boilers.” Power System Engineering 20 (2): 37–39.Suche in Google Scholar

He, Z., H. Qi, Y. Yao, and L. Ruan. 2015. “Inverse Estimation of the Particle Size Distribution Using the Fruit Fly Optimization Algorithm.” Applied Thermal Engineering 88: 306–14.10.1016/j.applthermaleng.2014.08.057Suche in Google Scholar

Hu, L., Y. Liu, G. Yi, N. Li, and D. Che. 2013. “Effects of Air Staging Conditions on the Combustion and NOx Emission Characteristics in a 600 MW Wall Fired Utility Boiler Using Lean Coal.” Energy & Fuels 27(10): 5831–40.10.1021/ef401354gSuche in Google Scholar

Jiang, B., F. G. Liu, K. Liu, and H. J. Liu. 2014. “Experimental Research on High Temperature Corrosion Prevention Technology for Water Wall of Opposed Wall Fired Ultra Supercritical Boiler.” Applied Mechanics & Materials 654: 69–73.10.4028/www.scientific.net/AMM.654.69Suche in Google Scholar

Klein, D. H., A. W. Andren, J. A. Carter, J. F. Emery, C. Feldman, W. Fulkerson, W. S. Lyon, J. C. Ogle, and Y. Talmi. 1975. “Pathways of Thirty-Seven Trace Elements through Coal-Fired Power Plant.” Environmental Science & Technology 9: 10.10.1021/es60108a007Suche in Google Scholar

Kohli, A., and D. G. Bogard. 1997. “Adiabatic Effectiveness, Thermal Fields, and Velocity Fields for Film Cooling with Large Angle Injection.” Journal of Turbomachinery 119(2): 352–58.10.1115/1.2841118Suche in Google Scholar

Li, J., X. Zhuang, X. Querol, O. Font, N. Moreno, and J. Zhou. 2012. “Environmental Geochemistry of the Feed Coals and Their Combustion By-Products from Two Coal-Fired Power Plants in Xinjiang Province, Northwest China.” Fuel 95(95): 446–56.10.1016/j.fuel.2011.10.025Suche in Google Scholar

Li, Zhengqi, Lingyan Zeng, Guangbo Zhao, Jing Li, Shanping Shen, and Fucheng Zhang. 2011. “Numerical Simulations of Combustion Characteristics and NOx Emissions for Two Configurations of Swirl Coal Burners in a 300 MWe Wall-Fired Boiler.” Numerical Heat Transfer 60(5): 441–60.10.1080/10407782.2011.600618Suche in Google Scholar

Liang, S. H., H. Lei, and E. X. Zhang. 2009. “Study on On-Line Monitoring Technology for High Temperature Corrosion of Boilers.” Journal of Power Engineering 29 (12): 1093–1095.Suche in Google Scholar

Liu, J. 2007. “Expermental Research on Flat Plate Film Cooling Effectiveness at Different Injection Angles.” Journal of Engineering Thermophysics 28(3): 409–11.Suche in Google Scholar

Lu, Y., T. Chen, J. Liu, Q. Huang, G. Chen, B. Jin, and Z. Yong. 2015. “Influence of Closing-To-Wall Air on Combustion Process in 660MW Opposed Firing Boiler.” Journal of Southeast University 45(1): 85–90.Suche in Google Scholar

Min, K., Z. Li, Z. Ling, X. Jing, and Q. Zhu. 2014. “Effect of Overfire Air Angle on Flow Characteristics within a Small-Scale Model for a Deep-Air-Staging Down-Fired Furnace.” Energy Conversion & Management 79(79): 367–76.10.1016/j.enconman.2013.12.012Suche in Google Scholar

Mohr, S. H., and G. M. Evans. 2009. “Forecasting Coal Production until 2100.” Fuel 88(11): 2059–67.10.1016/j.fuel.2009.01.032Suche in Google Scholar

Qiong, L. I., W. U. Yuxin, H. Yang, and L. Junfu. 2013. “Simulation and Optimization of SNCR Process.” Ciesc Journal 64 (5): 1789–1796.Suche in Google Scholar

Qiu, Jihua, M Liming, Xuexin Sun, and Yonggang Liu. 1999. “The Corrosion of Water Wall in Wall Fired Boiler.” Journal of Huazhong University Ofence & Technology 27(1): 63–65.Suche in Google Scholar

Ti, S., Z. Chen, M. Kuang, Z. Li, Q. Zhu, H. Zhang, Z. Wang, and G. Xu. 2016. “Numerical Simulation of the Combustion Characteristics and NO X Emission of a Swirl Burner: Influence of the Structure of the Burner Outlet.” Applied Thermal Engineering 104: 565–76.10.1016/j.applthermaleng.2016.05.079Suche in Google Scholar

Wang, J., K. Zheng, R. Singh, H. Lou, J. Hao, B. Wang, and F. Cheng. 2017. “Numerical Simulation and Cold Experimental Research of a low-NO X Combustion Technology for Pulverized Low-Volatile Coal.” Applied Thermal Engineering 114: 498–510.10.1016/j.applthermaleng.2016.11.204Suche in Google Scholar

Wu, Z., Z. N. Zhuang, T. S. Liu, G. U. Jie, and H. C. Xia. 2005. “Study on Slagging Problem in the Furnace of a Tangential Fired Boiler.” Proceedings of the Csee 25(4): 131–35.Suche in Google Scholar

Xiu-Qing, X. U., and R. L. Zeng. 2001. “High Temperature Corrosion of Water Wall for Tangentially Fired Boiler Furnace.” Power System Engineering 17 (2): 77–79.Suche in Google Scholar

Yang, W., R. You, Z. Wang, H. Zhang, Z. Zhou, J. Zhou, J. Guan, and L. Qiu. 2017. “Effects of Near-Wall Air Application in a Pulverized-Coal 300 MWe Utility Boiler on Combustion and Corrosive Gases.” Energy & Fuels 31(9): 10075–81.10.1021/acs.energyfuels.7b01476Suche in Google Scholar

Zhang, J. B. 2011. “Research on High-Temperature Corrosion of Ultra-Supercritical Opposed Firing Boiler.” Zhejiang Electric Power 30 (4): 4– 6.Suche in Google Scholar

Zhixiang, Zhang, Cheng Dingnan, Wang Yungang, and Zhao Qinxin. 2011. “Structure Design and Optimizing Simulation of a New Type Closing-To-Wall Air Device.” Journal of Chinese Society of Power Engineering 31(2): 79–84.Suche in Google Scholar

Zhou, H., G. Mo, D. Si, and K. Cen. 2011. “Numerical Simulation of the NOx Emissions in a 1000 MW Tangentially Fired Pulverized-Coal Boiler: Influence of the Multi-Group Arrangement of the Separated over Fire Air.” Energy & Fuels 25(5): 2004–12.10.1021/ef200227rSuche in Google Scholar

Zhou, H., Y. Yang, H. Liu, and Q. Hang. 2014. “Numerical Simulation of the Combustion Characteristics of a Low NO X Swirl Burner: Influence of the Primary Air Pipe.” Fuel 130(5): 168–76.10.1016/j.fuel.2014.04.028Suche in Google Scholar

Zhou, Y. G., L. I. Pei, A. O. Xiang, and Z. Hong. 2015. “High Temperature Corrosion Inhibition for Opposed Firing Boiler Based on Combustion Distribution Evenness.” Journal of Zhejiang University 49 (9): 1768–1775.Suche in Google Scholar

Received: 2018-04-24
Revised: 2018-12-05
Accepted: 2019-01-28
Published Online: 2019-02-14