Abstract
The objective of this study was to demonstrate the necessity of using different methods for amyloidogenic light chain detection. Serum and urine agarose gel electrophoresis and immunofixation, as well as serum free light chain (FLC) immunoassay measurements, were evaluated in a patient with verified multiple myeloma and consequent AL amyloidosis confirmed by Congo red staining and immunofluorescence techniques. Conventional chemistry tests [serum and urine electrophoresis (SPE and UPE); serum and urine immunofixation (SIFE and UIFE)] were inconclusive. Only quantitative FLC immunoassay (serum free light chain immunoanalysis, SFLC) provided correct diagnostic information. A combination of gel-based SIFE and UIFE with more novel quantitative FLC immunoassays appears necessary when searching for monoclonal immunoglobulin light chain-related diseases.
Acknowledgments
The authors would like to thank Petr Pavlíček, MD from the Hematology Clinic, Faculty Hospital Královské Vinohrady, Prague, Czech Republic for providing valuable clinical information.
Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.
Research funding: Our work was supported by the Ministry of Health of the Czech Republic (Grant number: AZV MZ 15-27579A).
Employment of leadership: None declared.
Honorarium: None declared.
Conflict of interest statement: The funding organization played no role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the report for publication.
References
1. Kidney Disease: Improving Global Outcomes (KDIGO) CKD Work Group. KDIGO 2012 Clinical practice guideline for the evaluation and management of chronic kidney disease. Kidney Inter., Suppl 2013;3:1–150.Search in Google Scholar
2. Rajkumar VS, Dimopoulos MA, Palumbo A, Blade J, Merlini G, Mateos MV, et al. International Myeloma Working Group updated criteria for the diagnosis of multiple myeloma. Lancet Oncol 2014;15:538–48.10.1016/S1470-2045(14)70442-5Search in Google Scholar
3. Lovat LB, Persey MR, Madhoo S, Pepys MB, Hawkins PN. The liver in systemic amyloidosis: insights from serum amyloid P component scintigraphy in 484 patients. Gut 1998;42:727–34.10.1136/gut.42.5.727Search in Google Scholar PubMed PubMed Central
4. Palladini G, Russo P, Bosoni T, Verga L, Sarais G, Lavatelli F, et al. Identification of amyloidogenic light chain requires the combination of serum-free light chain assay with immunofixation of serum and urine. Clin Chem 2009;55:499–504.10.1373/clinchem.2008.117143Search in Google Scholar PubMed
5. Katzmann JA, Kyle RA, Benson J, Larson DR, Snyder MR, Lust JA, et al. Screening panels for detection of monoclonal gammopathies. Clin Chem 2009;55:1517–22.10.1373/clinchem.2009.126664Search in Google Scholar PubMed PubMed Central
6. Bradwell AR, editor. Serum free light chain analysis plus Hevylite, 7th ed. Birmingham, UK: The Binding Site Group Ltd, 2015.Search in Google Scholar
7. Katzmann JA. Screening panels for monoclonal gammopathies: time to change. Clin Biochem Rev 2009;30:105–11.Search in Google Scholar
8. Nowrousian MR, Brandhorst D, Sammet C, Kellert M, Daniels R, Schuett P, et al. Serum free light chain analysis and urine immunofixation electrophoresis in patients with multiple myeloma. Clin Cancer Res 2005;11:8706–14.10.1158/1078-0432.CCR-05-0486Search in Google Scholar PubMed
9. Coriu D, Weaver K, Schell M, Eulitz M, Murphy CL, Weiss DT, et al. A molecular basis for nonsecretory myeloma. Blood 2004;104:829–31.10.1182/blood-2004-02-0477Search in Google Scholar PubMed
10. Attaelmannan M, Levinson SS. Understanding and identifying monoclonal gammopathies. Clin Chem 2000;46:1230–8.10.1093/clinchem/46.8.1230Search in Google Scholar
11. Tate J, Bazeley S, Sykes S, Mollee P. Quantitative serum free light chain assay – analytical issues. Clin Biochem Rev 2009;30:131–40.Search in Google Scholar
12. Kyle RA. Sequence of testing for monoclonal gammopathies. Arch Pathol Lab Med 1999;123:114–8.10.5858/1999-123-0114-SOTFMGSearch in Google Scholar PubMed
13. Sarav M, Wang Y, Hack BK, Chang A, Jensen M, Bao L, et al. Renal FcRn reclaims albumin but facilitates elimination of IgG. J Am Soc Nephrol 2009;20:1941–52.10.1681/ASN.2008090976Search in Google Scholar PubMed PubMed Central
14. Holding S, Spradbery D, Hoole R, Wilmot R, Shields LM, Levoguer AM, et al. Use of serum free light chain analysis and urine protein electrophoresis for detection of monoclonal gammopathies. Clin Chem Lab Med 2011;49:83–8.10.1515/CCLM.2011.010Search in Google Scholar PubMed
15. Graziani M, Merlini G, Petrini C. Guidelines for the analysis of Bence Jones protein. Clin Chem Lab Med 2003;41:338–46.10.1515/CCLM.2003.054Search in Google Scholar PubMed
16. Dispenzieri A, Kyle R, Merlini G, Miguel JS, Ludwig H, Hajek R, et al. International Myeloma Working Group guidelines for serum free light chain analysis in multiple myeloma and related disorders. Leukemia 2009;23:215–24.10.1038/leu.2008.307Search in Google Scholar PubMed
©2016 by De Gruyter
Articles in the same Issue
- Frontmatter
- Editorial
- Protein electrophoresis and serum free light chains in the diagnosis and monitoring of plasma cell disorders: laboratory testing and current controversies
- Laboratory Testing as Recommended by the Guidelines and the International Myeloma Working Group
- Laboratory testing requirements for diagnosis and follow-up of multiple myeloma and related plasma cell dyscrasias
- Free light chain testing for the diagnosis, monitoring and prognostication of AL amyloidosis
- Laboratory testing in monoclonal gammopathy of renal significance (MGRS)
- The impact of renal function on the clinical performance of FLC measurement in AL amyloidosis
- Serum and Urine Protein Electrophoresis and Immunofixation Testing
- Challenges of measuring monoclonal proteins in serum
- Screening immunofixation should replace protein electrophoresis as the initial investigation of monoclonal gammopathy: Point
- Should routine laboratories stop doing screening serum protein electrophoresis and replace it with screening immune-fixation electrophoresis? No quick fixes: Counterpoint
- Moving towards harmonized reporting of serum and urine protein electrophoresis
- Multiple qualitative and quantitative methods for free light chain analysis are necessary as first line tests for AL amyloidosis
- Use of isoelectric focusing to discriminate transient oligoclonal bands from monoclonal protein in treated myeloma
- New patterns of relapse in multiple myeloma: a case of “light chain escape” in which FLC predicted relapse earlier than urine and serum immunofixation
- Serum Free Light Chain Methods and Controversies
- Analytical issues of serum free light chain assays and the relative performance of polyclonal and monoclonal based reagents
- Measurement of free light chains with assays based on monoclonal antibodies
- Measurement of free light chains – pros and cons of current methods
- Is accuracy of serum free light chain measurement achievable?
- Performance goals for immunoglobulins and serum free light chain measurements in plasma cell dyscrasias can be based on biological variation
- A patient with AL amyloidosis with negative free light chain results
- Strengths and weaknesses of methods for identifying monoclonal free light chains of Ig: examples from two cases with renal disease
- Comparison of Freelite™ and N Latex serum free light chain assays in subjects with end stage kidney disease on haemodialysis
- New Laboratory Assays and Challenges
- Quantification of β-region IgA monoclonal proteins – should we include immunochemical Hevylite® measurements? Point
- Quantification of β region IgA paraproteins – should we include immunochemical “heavy/light chain” measurements? Counterpoint
- Free light chains and heavy/light chains in monitoring POEMS patients
- Monitoring free light chains in serum using mass spectrometry
- Monoclonal antibody therapeutics as potential interferences on protein electrophoresis and immunofixation
- Monitoring multiple myeloma patients treated with daratumumab: teasing out monoclonal antibody interference
- Interference of daratumumab in monitoring multiple myeloma patients using serum immunofixation electrophoresis can be abrogated using the daratumumab IFE reflex assay (DIRA)
- Letter to the Editor
- Discrepancy between FLC assays: only a problem of quantification?
Articles in the same Issue
- Frontmatter
- Editorial
- Protein electrophoresis and serum free light chains in the diagnosis and monitoring of plasma cell disorders: laboratory testing and current controversies
- Laboratory Testing as Recommended by the Guidelines and the International Myeloma Working Group
- Laboratory testing requirements for diagnosis and follow-up of multiple myeloma and related plasma cell dyscrasias
- Free light chain testing for the diagnosis, monitoring and prognostication of AL amyloidosis
- Laboratory testing in monoclonal gammopathy of renal significance (MGRS)
- The impact of renal function on the clinical performance of FLC measurement in AL amyloidosis
- Serum and Urine Protein Electrophoresis and Immunofixation Testing
- Challenges of measuring monoclonal proteins in serum
- Screening immunofixation should replace protein electrophoresis as the initial investigation of monoclonal gammopathy: Point
- Should routine laboratories stop doing screening serum protein electrophoresis and replace it with screening immune-fixation electrophoresis? No quick fixes: Counterpoint
- Moving towards harmonized reporting of serum and urine protein electrophoresis
- Multiple qualitative and quantitative methods for free light chain analysis are necessary as first line tests for AL amyloidosis
- Use of isoelectric focusing to discriminate transient oligoclonal bands from monoclonal protein in treated myeloma
- New patterns of relapse in multiple myeloma: a case of “light chain escape” in which FLC predicted relapse earlier than urine and serum immunofixation
- Serum Free Light Chain Methods and Controversies
- Analytical issues of serum free light chain assays and the relative performance of polyclonal and monoclonal based reagents
- Measurement of free light chains with assays based on monoclonal antibodies
- Measurement of free light chains – pros and cons of current methods
- Is accuracy of serum free light chain measurement achievable?
- Performance goals for immunoglobulins and serum free light chain measurements in plasma cell dyscrasias can be based on biological variation
- A patient with AL amyloidosis with negative free light chain results
- Strengths and weaknesses of methods for identifying monoclonal free light chains of Ig: examples from two cases with renal disease
- Comparison of Freelite™ and N Latex serum free light chain assays in subjects with end stage kidney disease on haemodialysis
- New Laboratory Assays and Challenges
- Quantification of β-region IgA monoclonal proteins – should we include immunochemical Hevylite® measurements? Point
- Quantification of β region IgA paraproteins – should we include immunochemical “heavy/light chain” measurements? Counterpoint
- Free light chains and heavy/light chains in monitoring POEMS patients
- Monitoring free light chains in serum using mass spectrometry
- Monoclonal antibody therapeutics as potential interferences on protein electrophoresis and immunofixation
- Monitoring multiple myeloma patients treated with daratumumab: teasing out monoclonal antibody interference
- Interference of daratumumab in monitoring multiple myeloma patients using serum immunofixation electrophoresis can be abrogated using the daratumumab IFE reflex assay (DIRA)
- Letter to the Editor
- Discrepancy between FLC assays: only a problem of quantification?