Abstract
Background: Serum free light chain (FLC) analysis with ratio and urine immunofixation electrophoresis (IFE) are both available for routine use in helping to detect plasma cell dyscrasia and related diseases.
Cases: Case reports showing one serum positive for serum FLC but that showed a hook effect and overestimated the amount of monoclonal FLC while urine IFE was negative for Bence Jones protein, and a second serum that showed elevated FLC κ and λ but a normal κ/λ ratio, while urine IFE was positive for Bence Jones protein.
Conclusions: These two techniques complement one another. Neither of the techniques is truly quantitative, and both exhibit methodological defects.
References
1. Keren DF, Alexanian R, Goeken JA, Gorevic PD, Kyle RA, Tomar RH. Guidelines for clinical and laboratory evaluation of patients with monoclonal gammopathies. Arch Pathol Lab Med 1999;123:106–7.10.5858/1999-123-0106-GFCALESearch in Google Scholar
2. Bradwell AR, Carr-Smith HD, Mead GP, Tang LX, Showell PJ, Drayson MT, et al. Highly sensitive, automated immunoassay for immunoglobulin free light chains in serum and urine. Clin Chem 2001;47:673–80.10.1093/clinchem/47.4.673Search in Google Scholar
3. Dispenzieri A, Kyle R, Merlini G, Miguel JS, Ludwig H, Hajek R, et al. International Myeloma Working Group guidelines for serum-free light chain analysis in multiple myeloma and related disorders. Leukemia 2009;23:215–24.10.1038/leu.2008.307Search in Google Scholar
4. Durie BG, Harousseau JL, Miguel JS, Blade J, Barlogie B, Anderson K, et al. International uniform response criteria for multiple myeloma. Leukemia 2006;20:1467–73.10.1038/sj.leu.2404284Search in Google Scholar
5. Rajkumar SV, Dimopoulos MA, Palumbo A, Blade J, Merlini G, Mateos MV, et al. International Myeloma Working Group updated criteria for the diagnosis of multiple myeloma. Lancet Oncol 2014;15:e538–48.10.1016/S1470-2045(14)70442-5Search in Google Scholar
6. Katzmann JA, Dispenzieri A, Kyle RA, Snyder MR, Plevak MF, Larson DR, et al. Elimination of the need for urine studies in the screening algorithm for monoclonal gammopathies by using serum immunofixation and free light chain assays. Mayo Clin Proc 2006;81:1575–8.10.4065/81.12.1575Search in Google Scholar PubMed
7. Levinson SS. Studies of Bence Jones proteins by immunonephelometry. Ann Clin Lab Sci 1992;22:100–9.Search in Google Scholar
8. Bosmann M, Kossler J, Stolz H, Walter U, Knop S, Steigerwald U. Detection of serum free light chains: the problem with antigen excess. Clin Chem Lab Med 2010;48:1419–22.10.1515/CCLM.2010.283Search in Google Scholar PubMed
9. Briand PY, Decaux O, Caillon H, Grosbois B, Le Treut A, Guenet L. Analytical performance of the serum free light chain assay. Clin Chem Lab Med 2010;48:73–9.10.1515/CCLM.2010.012Search in Google Scholar PubMed
10. de Kat Angelino CM, Raymakers R, Teunesen MA, Jacobs JF, Klasen IS. Overestimation of serum kappa free light chain concentration by immunonephelometry. Clin Chem 2010;56: 1188–90.10.1373/clinchem.2010.143529Search in Google Scholar PubMed
11. Levinson SS. Regarding the overestimation of serum {kappa} free light chains. Clin Chem 2011;57:775–7.10.1373/clinchem.2010.158774Search in Google Scholar PubMed
12. Tate JR, Gill D, Cobcroft R, Hickman PE. Practical considerations for the measurement of free light chains in serum. Clin Chem 2003;49:1252–7.10.1373/49.8.1252Search in Google Scholar PubMed
13. Hutchison CA, Harding S, Hewins P, Mead GP, Townsend J, Bradwell AR, et al. Quantitative assessment of serum and urinary polyclonal free light chains in patients with chronic kidney disease. Clin J Am Soc Nephrol 2008;3:1684–90.10.2215/CJN.02290508Search in Google Scholar PubMed PubMed Central
14. Palladini G, Russo P, Bosoni T, Verga L, Sarais G, Lavatelli F, et al. Identification of amyloidogenic light chains requires the combination of serum-free light chain assay with immunofixation of serum and urine. Clin Chem 2009;55: 499–504.10.1373/clinchem.2008.117143Search in Google Scholar PubMed
15. Uljon SN, Richardson PG, Schur PH, Anderson KC, Tanasijevic MJ, Lindeman NI. Serial serum free light chain measurements do not detect changes in disease status earlier than electrophoretic M-spike measurements in patients with intact immunoglobulin myeloma. Clin Chim Acta 2011;412:562–8.10.1016/j.cca.2010.12.002Search in Google Scholar PubMed
16. Levinson SS. Complementarily of urine analysis and serum free light chain assay for assessing response treatment response: illustrated by three case examples. Clin Chim Acta 2011;412:2206–10.10.1016/j.cca.2011.08.012Search in Google Scholar PubMed
©2016 by De Gruyter
Articles in the same Issue
- Frontmatter
- Editorial
- Protein electrophoresis and serum free light chains in the diagnosis and monitoring of plasma cell disorders: laboratory testing and current controversies
- Laboratory Testing as Recommended by the Guidelines and the International Myeloma Working Group
- Laboratory testing requirements for diagnosis and follow-up of multiple myeloma and related plasma cell dyscrasias
- Free light chain testing for the diagnosis, monitoring and prognostication of AL amyloidosis
- Laboratory testing in monoclonal gammopathy of renal significance (MGRS)
- The impact of renal function on the clinical performance of FLC measurement in AL amyloidosis
- Serum and Urine Protein Electrophoresis and Immunofixation Testing
- Challenges of measuring monoclonal proteins in serum
- Screening immunofixation should replace protein electrophoresis as the initial investigation of monoclonal gammopathy: Point
- Should routine laboratories stop doing screening serum protein electrophoresis and replace it with screening immune-fixation electrophoresis? No quick fixes: Counterpoint
- Moving towards harmonized reporting of serum and urine protein electrophoresis
- Multiple qualitative and quantitative methods for free light chain analysis are necessary as first line tests for AL amyloidosis
- Use of isoelectric focusing to discriminate transient oligoclonal bands from monoclonal protein in treated myeloma
- New patterns of relapse in multiple myeloma: a case of “light chain escape” in which FLC predicted relapse earlier than urine and serum immunofixation
- Serum Free Light Chain Methods and Controversies
- Analytical issues of serum free light chain assays and the relative performance of polyclonal and monoclonal based reagents
- Measurement of free light chains with assays based on monoclonal antibodies
- Measurement of free light chains – pros and cons of current methods
- Is accuracy of serum free light chain measurement achievable?
- Performance goals for immunoglobulins and serum free light chain measurements in plasma cell dyscrasias can be based on biological variation
- A patient with AL amyloidosis with negative free light chain results
- Strengths and weaknesses of methods for identifying monoclonal free light chains of Ig: examples from two cases with renal disease
- Comparison of Freelite™ and N Latex serum free light chain assays in subjects with end stage kidney disease on haemodialysis
- New Laboratory Assays and Challenges
- Quantification of β-region IgA monoclonal proteins – should we include immunochemical Hevylite® measurements? Point
- Quantification of β region IgA paraproteins – should we include immunochemical “heavy/light chain” measurements? Counterpoint
- Free light chains and heavy/light chains in monitoring POEMS patients
- Monitoring free light chains in serum using mass spectrometry
- Monoclonal antibody therapeutics as potential interferences on protein electrophoresis and immunofixation
- Monitoring multiple myeloma patients treated with daratumumab: teasing out monoclonal antibody interference
- Interference of daratumumab in monitoring multiple myeloma patients using serum immunofixation electrophoresis can be abrogated using the daratumumab IFE reflex assay (DIRA)
- Letter to the Editor
- Discrepancy between FLC assays: only a problem of quantification?
Articles in the same Issue
- Frontmatter
- Editorial
- Protein electrophoresis and serum free light chains in the diagnosis and monitoring of plasma cell disorders: laboratory testing and current controversies
- Laboratory Testing as Recommended by the Guidelines and the International Myeloma Working Group
- Laboratory testing requirements for diagnosis and follow-up of multiple myeloma and related plasma cell dyscrasias
- Free light chain testing for the diagnosis, monitoring and prognostication of AL amyloidosis
- Laboratory testing in monoclonal gammopathy of renal significance (MGRS)
- The impact of renal function on the clinical performance of FLC measurement in AL amyloidosis
- Serum and Urine Protein Electrophoresis and Immunofixation Testing
- Challenges of measuring monoclonal proteins in serum
- Screening immunofixation should replace protein electrophoresis as the initial investigation of monoclonal gammopathy: Point
- Should routine laboratories stop doing screening serum protein electrophoresis and replace it with screening immune-fixation electrophoresis? No quick fixes: Counterpoint
- Moving towards harmonized reporting of serum and urine protein electrophoresis
- Multiple qualitative and quantitative methods for free light chain analysis are necessary as first line tests for AL amyloidosis
- Use of isoelectric focusing to discriminate transient oligoclonal bands from monoclonal protein in treated myeloma
- New patterns of relapse in multiple myeloma: a case of “light chain escape” in which FLC predicted relapse earlier than urine and serum immunofixation
- Serum Free Light Chain Methods and Controversies
- Analytical issues of serum free light chain assays and the relative performance of polyclonal and monoclonal based reagents
- Measurement of free light chains with assays based on monoclonal antibodies
- Measurement of free light chains – pros and cons of current methods
- Is accuracy of serum free light chain measurement achievable?
- Performance goals for immunoglobulins and serum free light chain measurements in plasma cell dyscrasias can be based on biological variation
- A patient with AL amyloidosis with negative free light chain results
- Strengths and weaknesses of methods for identifying monoclonal free light chains of Ig: examples from two cases with renal disease
- Comparison of Freelite™ and N Latex serum free light chain assays in subjects with end stage kidney disease on haemodialysis
- New Laboratory Assays and Challenges
- Quantification of β-region IgA monoclonal proteins – should we include immunochemical Hevylite® measurements? Point
- Quantification of β region IgA paraproteins – should we include immunochemical “heavy/light chain” measurements? Counterpoint
- Free light chains and heavy/light chains in monitoring POEMS patients
- Monitoring free light chains in serum using mass spectrometry
- Monoclonal antibody therapeutics as potential interferences on protein electrophoresis and immunofixation
- Monitoring multiple myeloma patients treated with daratumumab: teasing out monoclonal antibody interference
- Interference of daratumumab in monitoring multiple myeloma patients using serum immunofixation electrophoresis can be abrogated using the daratumumab IFE reflex assay (DIRA)
- Letter to the Editor
- Discrepancy between FLC assays: only a problem of quantification?