Home Quantification of hemoglobin A1c by off-line HPLC separation and liquid chromatography-tandem mass spectrometry: a modification of the IFCC reference measurement procedure
Article
Licensed
Unlicensed Requires Authentication

Quantification of hemoglobin A1c by off-line HPLC separation and liquid chromatography-tandem mass spectrometry: a modification of the IFCC reference measurement procedure

  • Tianjiao Zhang , Chuanbao Zhang , Wenxiang Chen , Haijian Zhao , Jiangtao Zhang , Weiyan Zhou , Jie Zeng , Jing Wang and Donghuan Wang EMAIL logo
Published/Copyright: October 10, 2015

Abstract

Background: The quality of hemoglobin A1c measurement is very important in the management of diabetes. A reference system has been established by the IFCC Working Group on HbA1c Standardization. We did some modification of the IFCC Reference Measurement Procedure with MS detection which significantly decreased the analysis time and improved the precision of the analytes by off-line HPLC separation and liquid chromatography-tandem mass spectrometry (LC/MS/MS) analysis.

Methods: The samples were prepared and enzymatically cleaved according to the IFCC HbA1c reference measurement procedure. Then the digest solution was injected to a reversed phase HPLC for purification and a clean fraction was collected. The fraction was analyzed by liquid chromatography-tandem mass spectrometry with an isocratic elution on a C18 column. Liner regression was used to determine the concentration of HbA1c.

Results: The total analysis time which includes the off-line HPLC separation and the LC/MS/MS analysis was reduced by at least 65% compared to the existing IFCC method. The transitions of m/z 348.4→237.2 and m/z 429.4→245.2 were selected for quantification of non-glycated and glycated hexapeptide. Fifty seven hemolysate samples used in recent 3-years’ IFCC HbA1c inter-laboratory studies (2012–2014) were analyzed by the LC/MS/MS procedure for method validation. The CVS were between 0.16% and 1.87% for 4 measurements per sample in the concentration range for HbA1c between 30.4 and 145.8 mmol/mol. The relative bias of the LC/MS/MS method was varied from -3.21% to 2.47% compared to the IFCC network assigned values.

Conclusions: This method is an efficient and reliable procedure for the determination of HbA1c. After thorough evaluation within the IFCC Network this modification may be implemented in the IFCC RMP for HbA1c with MS detection.


Corresponding author: Donghuan Wang, Beijing Hospital, National Center for Clinical laboratories, Division of clinical chemistry, Beijing, P. R. China, E-mail:

Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.

Research funding: National Natural Science Foundation of China, (Grant/Award Number: 81171665, 81301488).

Employment or leadership: None declared.

Honorarium: None declared.

Competing interests: The funding organization(s) played no role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the report for publication.

References

1. Sacks DB, Bruns DE, Goldstein DE, Maclaren NK, McDonald JM, Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2002;48:436–72.10.1093/clinchem/48.3.436Search in Google Scholar

2. American Diabetes Association. Standards of medical care in diabetes. Diabetes Care 2004;27:Suppl 1:S15–35.10.2337/diacare.27.2007.S15Search in Google Scholar

3. International expert committee. International expert committee report on the role of the A1c assay in the diagnosis of diabetes. Diabetes Care 2009;32:1327–34.10.2337/dc09-9033Search in Google Scholar PubMed PubMed Central

4. American Diabetes Association. Standards of medical care in diabetes–2010. Diabetes Care 2010;33:Suppl 1:S11–61.10.2337/dc10-S011Search in Google Scholar PubMed PubMed Central

5. American Diabetes Association. Diagnosis and classification of diabetes mellitus. Diabetes Care 2011;34:Suppl 1:S62–9.10.2337/dc11-S062Search in Google Scholar PubMed PubMed Central

6. WHO. Use of glycated haemoglobin (hbA1c) in the diagnosis of diabetes mellitus:Abbreviated report of a who consultation, 2011.Search in Google Scholar

7. Kobold U, Jeppsson J-O, Dulffer T, Finke A, Hoelzel W, Miedema K. Candidate reference methods for hemoglobin A1c based on peptide mapping. Clin Chem 1997;43:1944–51.10.1093/clinchem/43.10.1944Search in Google Scholar

8. Jeppsson J-O, Kobold U, Barr J, Finke A, Hoelzel W, Hoshino T, et al. Approved IFCC reference method for the measurement of hbA1c in human blood. Clin Chem Lab Med 2002;40:78–89.Search in Google Scholar

9. Finke A, Kobold U, Hoelzel W, Weykamp C, Miedema K, Jeppsson J-O. Preparation of a candidate primary reference material for the international standardisation of HbA1c determinations. Clin Chem Lab Med 1998;36:299–308.10.1515/CCLM.1998.051Search in Google Scholar PubMed

10. Weykamp C, John WG, Mosca A, Hoshino T, Little R, Jeppsson JO, et al. The IFCC reference measurement system for HbA1c: a 6-year progress report. Clin Chem 2008;54:240–8.10.1373/clinchem.2007.097402Search in Google Scholar PubMed

11. Kaiser P, Akerboom T, Molnar P, Reinauer H. Modified HPLC-electrospray ionization/mass spectrometry method for HbA1c based on IFCC reference measurement procedure. Clin Chem 2008;54:1018–22.10.1373/clinchem.2007.100875Search in Google Scholar PubMed

12. Papayannopoulos IA. The interpretation of collision-induced dissociation tandem mass spectra of peptides. Mass Spectrom Rev 1995;14:49–73.10.1002/mas.1280140104Search in Google Scholar

13. Willekens E, Thienpont L, Stockl D, Kobold U, Hoelzel W, De Leenheer AP. Quantification of glycohemoglobin in blood by mass spectrometry applying multiple-reaction monitoring. Clin Chem 2000;46:281–3.10.1093/clinchem/46.2.281Search in Google Scholar

14. Wong L, Liu H, Yong S, Liu Q, Lee TK. Improved reference measurement method for hemoglobin A1c by use of liquid chromatography-isotope dilution-tandem mass spectrometry. Clin Chem 2015;61:435–6.10.1373/clinchem.2014.231340Search in Google Scholar

15. Nakanishi T, Shimizu A. Determination of ionization efficiency of glycated and non-glycated peptides from the n-terminal of hemoglobin beta-chain by electrospray ionization mass spectrometry. J Chromatogr B Biomed Sci Appl 2000;746:83–9.10.1016/S0378-4347(00)00115-8Search in Google Scholar


Supplemental Material

The online version of this article (DOI: 10.1515/cclm-2015-0365) offers supplementary material, available to authorized users.


Received: 2015-4-17
Accepted: 2015-9-2
Published Online: 2015-10-10
Published in Print: 2016-4-1

©2016 by De Gruyter

Articles in the same Issue

  1. Frontmatter
  2. Editorial
  3. Macroprolactin: searching for a needle in a haystack?
  4. Review
  5. Laboratory medicine in the new healthcare environment
  6. Opinion Paper
  7. Developing GRADE outcome-based recommendations about diagnostic tests: a key role in laboratory medicine policies
  8. EFLM Survey
  9. Accreditation process in European countries – an EFLM survey
  10. Genetics and Molecular Diagnostics
  11. HB Puerta del Sol [HBA1:c.148A>C], HB Valdecilla [HBA2:c.3G>T], HB Gran Vía [HBA2:c.98T>G], HB Macarena [HBA2:c.358C>T] and HB El Retiro [HBA2:c.364_366dupGTG]: description of five new hemoglobinopathies
  12. General Clinical Chemistry and Laboratory Medicine
  13. A candidate reference method using ICP-MS for sweat chloride quantification
  14. Quantification of hemoglobin A1c by off-line HPLC separation and liquid chromatography-tandem mass spectrometry: a modification of the IFCC reference measurement procedure
  15. Comparison between B·R·A·H·M·S PCT direct, a new sensitive point-of-care testing device for rapid quantification of procalcitonin in emergency department patients and established reference methods – a prospective multinational trial
  16. Evaluation of a hand-held blood gas analyzer for rapid determination of blood gases, electrolytes and metabolites in intensive care setting
  17. Use of a faecal immunochemical test for haemoglobin can aid in the investigation of patients with lower abdominal symptoms
  18. A possible cause of the variable detectability of macroprolactin by different immunoassay systems
  19. A multicenter comparison of whole blood vitamin B6 assays
  20. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays
  21. Development and validation of a 2nd tier test for identification of purine nucleoside phosphorylase deficiency patients during expanded newborn screening by liquid chromatography-tandem mass spectrometry
  22. A cross-sectional study of biomarkers of exposure and effect in smokers and moist snuff consumers
  23. Reference Values and Biological Variations
  24. Pediatric reference value distributions and covariate-stratified reference intervals for 29 endocrine and special chemistry biomarkers on the Beckman Coulter Immunoassay Systems: a CALIPER study of healthy community children
  25. Development of reference intervals for serum alkaline phosphatase among adults in Southern China traced to the new IFCC reference measurement procedure
  26. Birth season predicts the values of red blood cell distribution width (RDW) in adulthood
  27. Cardiovascular Diseases
  28. Cardiovascular risk stratification in hemodialysis patients in the era of highly sensitive troponins: should we choose between hs-troponin I and hs-troponin T?
  29. A standardised FACS assay based on native, receptor transfected cells for the clinical diagnosis and monitoring of β1-adrenergic receptor autoantibodies in human heart disease
  30. Infectious Diseases
  31. The diagnostic value of serum fucosylated fetuin A in hepatitis B virus-related liver diseases
  32. Letters to the Editor
  33. Discriminant indices for distinguishing thalassemia and iron deficiency in patients with microcytic anemia
  34. Discriminant indices for distinguishing thalassemia and iron deficiency in patients with microcytic anemia: a reply
  35. STORE (Sample Tracking: Organization, Refrigeration and Expansion): a project in a clinical laboratory perspective
  36. Control materials for immunochromatographic strip used for α-thalassemia screening
  37. Comparison of a 10- vs. 15-min centrifugation time for chemical and immunochemical assays and impact on turnaround time in a hospital laboratory
  38. Pre-analytical phase in cryoglobulin (CRG) detection: an alternative method for sample transport
  39. The efficacy of an internet-based e-learning system using the CellaVision Competency Software for continuing professional development
  40. Clinical examinations after the Fukushima disaster: a case report of Soma General Hospital
  41. Non-fasting plasma glucose concentration in blood donors
  42. Analytical evaluation of a second generation assay for chromogranin A; a dual-site study
  43. UBE3A, c.1347_1348delGA: a mutation in question
Downloaded on 10.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/cclm-2015-0365/html
Scroll to top button