Abstract
Photoplethysmography (PPG) waveforms are rich in cardiovascular information, and hence, their analysis is significant in the diagnosis and prevention of cardiovascular diseases (CVDs). The second derivative of photoplethysmography (SDPPG) analysis for the accurate detection of significant points in characterising the PPG waveform is challenging. In this paper, a SDPPG analysis algorithm is proposed based on a resampling technique which normalises the signal and ensures the presence of all significant points of interest in all its recurrences. The proposed delineator detects a, b and e waves in SDPPG, which are based on the combined analysis of PPG waveforms and their second derivatives, characterising them beat-by-beat by electrocardiogram (ECG) signals. Experiments have been conducted on 46 PPG signal records, each of 10-s duration with low and varying amplitudes, and regular and irregular heart rhythms for healthy adults, as well as unhealthy and aged patients obtained from the large-scale openly available database PhysioNet. Based on the experiments conducted, it is found that the proposed algorithm performs better than existing methods in terms of sensitivity and positive predictivity with a highest sensitivity of 99.84% with respect to a (onset) and b waves, 99.67% for e waves (dicrotic notch), and 100% of positive predictivity for a and b waves and 99.82% in case of e waves.
References
[1] Alty SR, Angarita-Jaimes N, Millasseau SC, Chowienczyk PJ. Predicting arterial stiffness from the digital volume pulse waveform. IEEE Trans Biomed Eng 2007; 54: 2268–2275.10.1109/TBME.2007.897805Search in Google Scholar
[2] Baek HJ, Kim JS, Kim YS, Lee HB, Park KS. Second derivative of photoplethysmography for estimating vascular aging. The 6th International Special Topic Conference on Information Technology Applications in Biomedicine, Tokyo, 2007; 70–72.10.1109/ITAB.2007.4407346Search in Google Scholar
[3] Blazek R, Lee C. Multi-resolution linear model comparison for detection of dicrotic notch and peak in blood volume pulse signals. 20-th International EURASIP Conference. Biosignal 2010; Czech Republic, 378–386.Search in Google Scholar
[4] Bortolotto A, Jacques B, Takeshi K, Kenji T, Michel S. Assessment of vascular aging and atherosclerosis in hypertensive subjects: second derivative of photoplethysmogram versus pulse wave velocity. Am J Hypertens 2000; 13: 165–171.10.1016/S0895-7061(99)00192-2Search in Google Scholar
[5] Dawber TR, Thomas HE Jr, McNamara PM. Characteristics of the dicrotic notch of the arterial pulse wave in coronary heart disease. Angiology 1973; 24: 244–255.10.1177/000331977302400407Search in Google Scholar
[6] Donelli A, Jansen JR, Hoeksel B, Pedeferri P, Hanania R, Bovelander J. Performance of a real-time dicrotic notch detection and predication algorithm in arrhythmic human aortic pressure signals. J Clin Monit Comput 2002; 17: 182–185.10.1023/A:1020737232676Search in Google Scholar
[7] Elgendi M. On the analysis of fingertip photoplethysmogram signals. Curr Cardiol Rev 2012; 8: 14–25.10.2174/157340312801215782Search in Google Scholar
[8] Elgendi M, Jonkman M, De Boer F. Heart rate variability and acceleration plethysmogram measured at rest. In: Fred A, Filipe J, Gamboa H, editors. Biomedical engineering systems and technologies: Springer, Communications in Computer and Information Science 2011: 266–277.10.1007/978-3-642-18472-7_21Search in Google Scholar
[9] Elgendi M, Norton I, Brearley M, Abbott D, Schuurmans D. Detection of a and b waves in the acceleration photoplethysmogram. Biomed Eng Online 2014; 13: 139.10.1186/1475-925X-13-139Search in Google Scholar
[10] Imanaga I, Hara H, Koyanagi S, Tanaka K. Correlation between wave components of the second derivative of plethysmogram and arterial distensibility. Jpn Heart J 1998; 39: 775–784.10.1536/ihj.39.775Search in Google Scholar
[11] Kinias P, Fozzard H, Norusis M. A real-time pressure algorithm. Comput Biol Med 1981; 11: 211–220.10.1016/S0010-4825(81)80023-6Search in Google Scholar
[12] Laleg TM, Crepeau E, Sorine M. Separation of arterial pressure into a nonlinear superposition of solitary waves and a windkessel flow. Biomed Signal Process Control 2007; 2: 163–170.10.1016/j.bspc.2007.05.004Search in Google Scholar
[13] Li BN, Dong MC, Vai MI. On an automatic delineator for arterial blood pressure waveforms. Biomed Signal Process Control 2010; 5: 76–81.10.1016/j.bspc.2009.06.002Search in Google Scholar
[14] Millasseau SC, Kelly RP, Ritter JM, Chowienczyk PJ. Determination of age-related increases in large artery stiffness by digital pulse contour analysis. Clin Sci (Lond) 2002; 103: 371–377.10.1042/cs1030371Search in Google Scholar PubMed
[15] Oppenheim MJ, Sittig DF. An innovative dicrotic notch detection algorithm which combines rule-based logic with digital signal processing techniques. Comput Biomed Res 1995; 28: 154–170.10.1006/cbmr.1995.1011Search in Google Scholar PubMed
[16] Otsuka T, Kawada T, Katsumata M, Ibuki C, Kusama Y. Independent determinants of second derivative of the finger photoplethysmogram among various cardiovascular risk factors in middle-aged men. Hypertens Res 2007; 30: 1211–1218.10.1291/hypres.30.1211Search in Google Scholar PubMed
[17] Shi P, Hu S, Zhu Y, Zheng J, Qiu Y, Cheang PY. Insight into the dicrotic notch in photoplethysmographic pulses from finger tip of young adults. J Med Eng Technol 2009; 33: 628–633.10.3109/03091900903150980Search in Google Scholar PubMed
[18] Takazawa K, Tanaka N, Fujita M, et al. Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform. Hypertension 1998; 32: 365–370.10.1161/01.HYP.32.2.365Search in Google Scholar
©2016 Walter de Gruyter GmbH, Berlin/Boston
Articles in the same Issue
- Frontmatter
- Editorial
- Biosignal analysis
- Research articles
- A method for reconstruction of visually evoked potentials from limited amount of sweeps
- Assessment of calibration methods on impedance pneumography accuracy
- Measuring multiple neuromuscular activation using EMG – a generalizability analysis
- Effect of toe extension on EMG of triceps surae muscles during isometric dorsiflexion
- Differences in mean arterial pressure of young and elderly people measured by oscilometry during inflation and deflation of the arm cuff
- Reliability analysis of the heart autonomic control parameters during hemodialysis sessions
- Remote vital parameter monitoring in neonatology – robust, unobtrusive heart rate detection in a realistic clinical scenario
- An adaptive delineator for photoplethysmography waveforms
- Uncoupling of cardiac and respiratory rhythm in atrial fibrillation
Articles in the same Issue
- Frontmatter
- Editorial
- Biosignal analysis
- Research articles
- A method for reconstruction of visually evoked potentials from limited amount of sweeps
- Assessment of calibration methods on impedance pneumography accuracy
- Measuring multiple neuromuscular activation using EMG – a generalizability analysis
- Effect of toe extension on EMG of triceps surae muscles during isometric dorsiflexion
- Differences in mean arterial pressure of young and elderly people measured by oscilometry during inflation and deflation of the arm cuff
- Reliability analysis of the heart autonomic control parameters during hemodialysis sessions
- Remote vital parameter monitoring in neonatology – robust, unobtrusive heart rate detection in a realistic clinical scenario
- An adaptive delineator for photoplethysmography waveforms
- Uncoupling of cardiac and respiratory rhythm in atrial fibrillation