Startseite Real-world assessment of Fluorecare SARS-CoV-2 Spike Protein Test Kit
Artikel Open Access

Real-world assessment of Fluorecare SARS-CoV-2 Spike Protein Test Kit

Eine Übersetzung des Artikels ist zu finden unter: https://doi.org/10.1515/almed-2021-0050
  • Gian Luca Salvagno , Gianluca Gianfilippi , Laura Pighi , Simone De Nitto , Brandon M. Henry und Giuseppe Lippi ORCID logo EMAIL logo
Veröffentlicht/Copyright: 24. Mai 2021

Abstract

Objectives

Since commercial SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) antigen rapid detection tests (Ag-RDTs) display broad diagnostic efficiency, this study aimed to evaluate the clinical performance of Fluorecare SARS-CoV-2 Spike Protein Test Kit in a real-life scenario.

Methods

The study population consisted of a series of patients undergoing SARS-Cov-2 diagnostic testing at Pederzoli Hospital of Peschiera del Garda (Verona, Italy). A nasopharyngeal swab was collected upon hospital admission and assayed with molecular (Altona Diagnostics RealStar® SARSCoV-2 RT-PCR Kit) and antigen (Fluorecare SARS-CoV-2 Spike Protein Test Kit) tests.

Results

The study population consisted of 354 patients (mean age, 47 ± 20 years; 195 women, 55.1%), 223 (65.8%) positive at molecular testing. A significant correlation was found between Fluorecare SARS-CoV-2 Spike Protein Test Kit and Altona (both S and E genes: r=−0.75; p<0.001). The cumulative area under the curve in all nasopharyngeal samples was 0.68. At ≥1.0 S/CO manufacturer’s cut-off, the sensitivity, specificity, negative and positive predictive values were 27.5, 99.2, 41.5 and 98.5%, respectively. Considerable improvement of sensitivity was observed as Ct values decreased, becoming 66.7% in samples with mean Ct values <30, 90.5% in those with mean Ct values <25, up to 100% in those with mean Ct values <20.

Conclusions

The modest sensitivity and negative predictive value of Fluorecare SARS-CoV-2 Spike Protein Test Kit makes unadvisable to use this assay as surrogate of molecular testing for definitively diagnosing SARS-CoV-2 infection, though its suitable sensitivity at high viral load could make it a reliable screening test for patients with higher infective potential.

Introduction

Due to the huge pressure imposed on routine diagnostic laboratories by the ongoing coronavirus disease 2019 (COVID-19) pandemic outbreak, rapid antigen tests hold premise as suitable alternatives for widespread, rapid and efficient identification of subjects with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection [1]. Nonetheless, as recently endorsed by both the World Health Organization (WHO) [2], and by the Task Force on COVID-19 of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) [3], the clinical performance of each SARS-CoV-2 antigen rapid detection test (Ag-RDT) must be thoroughly evaluated before its introduction – at whatever stage – into clinical practice. Therefore, this work was aimed to assess the clinical performance of Fluorecare SARS-CoV-2 Spike Protein Test Kit in a real-life scenario.

Materials and methods

Study population

Our study population consisted of a series of patients undergoing SARS-Cov-2 diagnosis at the Laboratory Medicine Service of the Pederzoli Hospital (Peschiera del Garda, Verona, Italy) between April 2 and 19, 2021, for being either symptomatic or in close contact with COVID-19 cases. A nasopharyngeal swab (Virus swab UTM™, Copan, Brescia, Italy) was immediately collected upon hospital admission and assayed with both molecular and antigen testing.

Molecular testing

SARS-CoV-2 nucleic acid amplification testing (NAAT) was carried out using Altona Diagnostics RealStar® SARSCoV-2 RT-PCR Kit (Altona Diagnostics GmbH, Hamburg, Germany). This real-time reverse transcription polymerase chain reaction (rRT-PCR) entails two separate amplifications and detections, independently targeting the SARS-CoV-2 E and S gene sequences. A probe and a primer set for internal control is also included in the test kit, for detecting possible rRT-PCR inhibition. The test was carried out on a Bio-Rad CFX96™ Deep Well Dx Real-Time PCR Detection System (Bio-Rad Laboratories, Hercules, CA, USA). Results were considered positive when the cycle threshold (Ct) values of both S and E SARS-CoV-2 genes were lower than 45.

Antigen testing

Antigen testing was carried out using the immunochromatographic assay Fluorecare SARS-CoV-2 Spike Protein Test Kit (Microprofit Biotech, Shenzhen, China). Briefly, patient nasopharyngeal sample is mixed with a solution containing fluorescently-labelled anti-SARS-CoV-2 spike protein antibodies and deposited in the sample window of the test kit. The eventually generated immunocomplexes migrate along a nitrocellulose membrane up to the detection area, where they generate a red line (in SARS-CoV-2 spike protein-positive samples). The fluorescently-labelled anti-SARS-CoV-2 spike protein antibodies also migrate towards a quality control window, where another line is generated to attest that the kit is working properly. The full test can be completed within 15–30 min. A dedicated point of care instrumentation can be used for quantitative fluorescence reading (Fluorecare MF-T1000; Microprofit Biotech, Shenzhen, China), which is then reported as arbitrary measuring unit (i.e., signal to cut-off; S/CO). The test is considered positive when the S/CO value is ≥1.0. According to the manufacturer, the percent positive and negative agreement vs. a reference RT-PCR technique is 92.2 and 100%, respectively.

Statistical analysis

In our study, the diagnostic performance of Fluorecare SARS-CoV-2 Spike Protein Test Kit vs. the reference NAAT was evaluated with Spearman’s correlation, by constructing receiver operating characteristic (ROC) curves, and calculating the diagnostic sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV). Statistical analysis was performed with Analyse-it software (Analyse-it Software s., Leeds, UK). This investigation was carried out as part of clinical laboratory operations, using pre-existing specimens collected for routine SARS-CoV-2 diagnostics at the local facility, and thereby patient informed consent and Ethical Committee approval were unnecessary. All test results were anonymized prior to statistical analysis. The study was conducted in accordance with the Declaration of Helsinki, under the terms of relevant local legislation.

Results

The final study population consisted of 354 patients (mean age, 47 ± 20 years; 195 women, 55.1%), 223 of whom (65.8%) were positive at NAAT (i.e., Ct values of both SARS-CoV-2 S and E genes <45). The Ct values of positive samples were 29.8 ± 7.1 and 30.3 ± 7.0 for the SARS-CoV-2 S and E genes, respectively. A highly significant Spearman’s correlation was found between values of Fluorecare SARS-CoV-2 Spike Protein Test Kit and measurable Ct values of S (r=−0.75; 95% CI, −0.80 to −0.69; p<0.001) and E (r=−0.75; 95% CI, −0.80 to −0.68; p<0.001) genes.

The overall diagnostic performance of Fluorecare SARS-CoV-2 Spike Protein Test Kit, as well as performance stratified according to Altona Ct values, is summarized in Table 1. The cumulative area under the curve (AUC) in all nasopharyngeal samples was 0.68. At the ≥1.0 S/CO manufacturer’s cut-off, the sensitivity, specificity, NPV and PPV values were 27.5, 99.2, 41.5 and 98.5%, respectively. The best cut-off calculated from the ROC curve was 0.18 S/CO, associated with 42.9% (95% CI, 36.5–49.5%) sensitivity, 92.6% (95% CI, 86.4–96.5%) specificity, 45.7% (95% CI, 42.7–48.8%) NPV and 91.7% (95% CI, 85.4–95.5%) PPV. Nonetheless, considerable improvement of diagnostic sensitivity was observed as the Ct values decreased, increasing to 66.7% in samples with mean Ct values <30, 90.5% in those with mean Ct values <25, up to 100% in those with very high viral load (i.e., mean Ct values <20).

Table 1:

Clinical performance of Fluorecare SARS-CoV-2 Spike Protein Test Kit stratified according to cycle threshold (Ct) values.

Ct values n AUC SN SP NPV PPV
All samples 354 0.68 (95% CI, 0.62–0.73) 27.5% (95% CI, 21.8–33.7%) 99.2% (95% CI, 95.5–100%) 41.5% (95% CI, 39.6–43.5%) 98.5% (95% CI, 90.0–99.8%)
<30 96 66.7% (95% CI, 56.3–76.0%)
<25 63 90.5% (95% CI, 80.4–96.4%)
<20 36 100% (95% CI, 90.3–100%)
  1. AUC, area under the curve; ACC, accuracy; SN, sensitivity; SP, specificity; NPV, negative predictive value; PPV, positive predictive value.

The distribution of Fluorecare SARS-CoV-2 Spike Protein Test Kit values according to the Altona thresholds for sample positivity (i.e., Ct values of both SARS-COV-2 S and E genes <45) or higher risk of infectivity (i.e., Ct values of both SARS-COV-2 S and E genes <26.3) is shown in Figure 1. The mean Fluorecare SARS-CoV-2 Spike Protein Test Kit values were found to be significantly higher in samples with Ct values <45 (n=233; 2.1 ± 3.6 S/CO) than in those with higher Ct values (n=121; 0.1 ± 0.1 S/CO; p<0.001), as well as in those with Ct values <26.3 (n=68; 6.7 ± 4.0 S/CO), than in those Ct values over this threshold (n=286; 0.2 ± 0.2 S/CO; p<0.001).

Figure 1: 
Distribution of Fluorecare SARS-CoV-2 Spike Protein Test Kit values according to the Altona thresholds for sample positivity (i.e., Ct values of both SARS-COV-2 S and E genes <45) and higher risk of infectivity (i.e., Ct values of both SARS-COV-2 S and E genes <26.3).
Ct, cycle threshold; SARS-CoV-2, severe acute respiratory syndrome coronavirus 2; S/CO, signal to cut-off.
Figure 1:

Distribution of Fluorecare SARS-CoV-2 Spike Protein Test Kit values according to the Altona thresholds for sample positivity (i.e., Ct values of both SARS-COV-2 S and E genes <45) and higher risk of infectivity (i.e., Ct values of both SARS-COV-2 S and E genes <26.3).

Ct, cycle threshold; SARS-CoV-2, severe acute respiratory syndrome coronavirus 2; S/CO, signal to cut-off.

Discussion

SARS-CoV-2 antigen testing, now mostly represented by Ag-RDT, is emerging as a possible alternative to overcome the dramatic burden posed on clinical laboratories by COVID-19 diagnostics [1, 4, 5]. A recent analysis of the Cochrane COVID-19 Diagnostic Test Accuracy Group has highlighted the theoretical advantages and possible drawbacks of these techniques [6]. As concerns the benefits, these tests are indeed simple, can be used easily by quickly trained staff or even by the patients themselves, do not necessitate centralized laboratory instrumentation and provide manageable results in a very short time. On the other hand, the clinical performance of Ag-RDTs is still considerably lower than that of molecular assay, and their cumulative diagnostic sensitivity remains limited at around 60–75% [6]. Especially modest performance has been reported in samples with low viral load (i.e., Ct values ≥25), with diagnostic sensitivity comprised between 30 and 50%, but increasing to 91–97% in samples with higher viral load (i.e., Ct values <25). Nevertheless, a rather broad heterogeneity of diagnostic performance of the different kits has been noted by the Cochrane COVID-19 Diagnostic Test Accuracy Group, with sensitivities ranging between dramatically low estimates (i.e., 12%), up to exceptionally high values (i.e., 90%, or even higher). This uncertain scenario has persuaded both the WHO and the IFCC Task Force on COVID-19 to recommend that each Ag-RDT should undergo a local validation process before being introduced into clinical practice [2], [3].

The results of our work have two major clinical implications. First, the relatively modest overall sensitivity and NPV of Fluorecare SARS-CoV-2 Spike Protein Test Kit would make it unadvisable to use this assay as alternative or even surrogate of conventional NAAT for precisely diagnosing SARS-CoV-2 infections. Nonetheless, its satisfactory sensitivity at higher nasopharyngeal viral load could make it a suitable test for screening patients with higher infective potential. A recent study, published by Gniazdowski et al. [7], found that the likelihood of obtaining a positive SARS-CoV-2 viral culture was <3% in nasopharyngeal samples with Altona Ct values <26.2. At a similar Ct threshold, Fluorecare SARS-CoV-2 Spike Protein Test Kit displayed a diagnostic sensitivity of around 90% in our cohort of unselected patients undergoing routine COVID-19 diagnostics, which would have permitted to identify the vast majority of individuals with high viral in the upper respiratory tract, who are those at the largest risk of spreading the virus in the community (i.e., the so-called super-spreaders), especially during mass gathering events [8].

Another important aspect to be considered, is that the nasopharyngeal viral load not only influence the likelihood of inter-individual SARS-CoV-2 transmission, but is also positively associated with the risk of progression towards severe/critical COVID-19 illness and/or death, as already demonstrated by several previous studies [9], [10], [11]. Therefore, rapid and efficient identification and/or monitoring of COVID-19 patients bearing high nasopharyngeal SARS-CoV-2 load during triage (even outside healthcare facilities), as well as during hospital stay or intensive care unit admission, would enable to establish a more timely and aggressive treatment, thus enhancing the likelihood of a positive outcome of this life-threatening disease.

In conclusion, our findings would hence suggest reserving the use of this Ag-RDT for identifying patients with higher viral load.


Corresponding author: Prof. Giuseppe Lippi, Section of Clinical Biochemistry, University Hospital of Verona, Piazzale L.A. Scuro, 10, 37134 Verona, Italy, Phone: +0039 045 8122970, Fax: +0039 045 8124308, E-mail:

Acknowledgments

The authors acknowledge the staff of the Service of Laboratory Medicine of the Pederzoli Hospital (Peschiera del Garda, Italy) for the skill technical assistance.

  1. Article Note: A translation of this article can be found here: https://doi.org/10.1515/almed-2021-0050.

  2. Research funding: None declared.

  3. Author contributions: All authors have accepted responsibility for the entire content of this manuscript and approved its submission.

  4. Competing interests: Authors state no conflict of interest.

  5. Informed consent: This investigation was carried out as part of clinical laboratory operations, using pre-existing specimens collected for routine SARS-CoV-2 diagnostics at the local facility, and thereby patient informed consent and Ethical Committee approval were unnecessary.

  6. Ethical approval: This investigation was carried out as part of clinical laboratory operations, using pre-existing specimens collected for routine SARS-CoV-2 diagnostics at the local facility, and thereby patient informed consent and Ethical Committee approval were unnecessary.

References

1. Mattiuzzi, C, Henry, BM, Lippi, G. Making sense of rapid antigen testing in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnostics. Diagnosis (Berl) 2020;8:27–31. https://doi.org/10.1515/dx-2020-0131.Suche in Google Scholar PubMed

2. World Health Organization. Antigen-detection in the diagnosis of SARS-CoV-2 infection using rapid immunoassays. Genève, Switzerland: World Health Organization; 2020.Suche in Google Scholar

3. Bohn, MK, Lippi, G, Horvath, AR, Erasmus, R, Grimmler, M, Gramegna, M, et al.. IFCC interim guidelines on rapid point-of-care antigen testing for SARS-CoV-2 detection in asymptomatic and symptomatic individuals. Clin Chem Lab Med 2021. https://doi.org/10.1515/cclm-2021.0455.Suche in Google Scholar

4. Lippi, G. Brief update on coronavirus disease 2019 (COVID-19) diagnostics. Adv Lab Med 2020;1:20200099. https://doi.org/10.1515/almed-2020-0099.Suche in Google Scholar

5. Lippi, G, Plebani, M. Laboratory medicine resilience during coronavirus disease 2019 (COVID-19) pandemic. Adv Lab Med 2020:20200035.10.5935/1676-2444.20200035Suche in Google Scholar

6. Dinnes, J, Deeks, JJ, Berhane, S, Taylor, M, Adriano, A, Davenport, C, et al.. Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection. Cochrane Database Syst Rev 2021;3:CD013705. https://doi.org/10.1002/14651858.CD013705.Suche in Google Scholar PubMed PubMed Central

7. Gniazdowski, V, Morris, CP, Wohl, S, Mehoke, T, Ramakrishnan, S, Thielen, P, et al.. Repeat COVID-19 molecular testing: correlation of SARS-CoV-2 culture with molecular assays and cycle thresholds. Clin Infect Dis 2020 Oct 27:ciaa1616. https://doi.org/10.1093/cid/ciaa1616 [Epub ahead of print].Suche in Google Scholar PubMed PubMed Central

8. Goyal, A, Reeves, DB, Cardozo-Ojeda, EF, Schiffer, JT, Mayer, BT. Viral load and contact heterogeneity predict SARS-CoV-2 transmission and super-spreading events. Elife 2021;10:e63537. https://doi.org/10.7554/elife.63537.Suche in Google Scholar PubMed PubMed Central

9. Westblade, LF, Brar, G, Pinheiro, LC, Paidoussis, D, Rajan, M, Martin, P, et al.. SARS-CoV-2 viral load predicts mortality in patients with and without cancer who are hospitalized with COVID-19. Canc Cell 2020;38:661–71. https://doi.org/10.1016/j.ccell.2020.09.007.Suche in Google Scholar PubMed PubMed Central

10. Pujadas, E, Chaudhry, F, McBride, R, Richter, F, Zhao, S, Wajnberg, A, et al.. SARS-CoV-2 viral load predicts COVID-19 mortality. Lancet Respir Med 2020;8:e70. https://doi.org/10.1016/s2213-2600(20)30354-4.Suche in Google Scholar

11. Alteri, C, Cento, V, Vecchi, M, Colagrossi, L, Fanti, D, Vismara, C, et al.. Nasopharyngeal SARS-CoV-2 load at hospital admission as predictor of mortality. Clin Infect Dis 2020 Jul 16:ciaa956. https://doi.org/10.1093/cid/ciaa956 [Epub ahead of print].Suche in Google Scholar PubMed PubMed Central

Received: 2021-04-28
Accepted: 2021-05-03
Published Online: 2021-05-24

© 2021 Gian Luca Salvagno et al., published by De Gruyter, Berlin/Boston

This work is licensed under the Creative Commons Attribution 4.0 International License.

Artikel in diesem Heft

  1. Frontmatter
  2. Editorial
  3. Prediabetes: what are we talking about?
  4. Prediabetes ¿de qué estamos hablando?
  5. Review / Artículo de Revisión
  6. Update and clinical management of anti-DNA auto-antibodies
  7. Actualización y manejo clínico de los anticuerpos anti-ácido desoxirribonucleico
  8. ¿Debemos adaptarnos los laboratorios clínicos a la realidad del paciente con enfermedad renal crónica en la cuantificación de la hormona paratiroidea?
  9. Should clinical laboratories adapt to the reality of chronic kidney disease in the determination of parathyroid hormone?
  10. Measurement and clinical usefulness of bilirubin in liver disease
  11. Bilirrubina: Medición y utilidad clínica en la enfermedad hepática
  12. Guidelines and Recommendations / Guias y Recomendaciones
  13. Management of post-analytical processes in the clinical laboratory according to ISO 15189:2012. Considerations about the management of clinical samples, ensuring quality of post-analytical processes, and laboratory information management
  14. Gestión del proceso posanalítico en los laboratorios clínicos según los requisitos de la norma ISO 15189:2012. Consideraciones sobre la gestión de muestras clínicas, aseguramiento de la calidad en el proceso posanalítico y gestión de la información del laboratorio
  15. Original Article / Artículo Original
  16. A descriptive and validation study of a predictive model of severity of SARS-COV-2 infection
  17. Estudio descriptivo y validación de un modelo predictivo de severidad en pacientes con infección por SARS-CoV-2
  18. Real-world assessment of Fluorecare SARS-CoV-2 Spike Protein Test Kit
  19. Evaluación de la prueba Fluorecare de anticuerpos contra la proteína Spike del SARS-CoV-2 en la práctica real
  20. Estimation of change limits (deltacheck) in clinical laboratory
  21. Estimación de los límites de cambio (deltacheck) en el laboratorio clínico
  22. An opportunity to emphasize the relevance of laboratory medicine
  23. Guías de práctica clínica: oportunidad para visibilizar la importancia de la medicina del laboratorio
  24. Case Report / Caso Clínico
  25. A novel variant in the COL4A3 gene: etiology of Alport syndrome type 2 in a 38-year-old male with suspected hereditary kidney disease
  26. Nueva variante en el gen COL4A3: etiología de un síndrome de Alport tipo 2 en varón de 38 años con sospecha de nefritis hereditaria
Heruntergeladen am 9.9.2025 von https://www.degruyterbrill.com/document/doi/10.1515/almed-2021-0041/html
Button zum nach oben scrollen