Abstract

A new device in assessment of cervical consistency by means of resistance to electrical current was compared to observations made by traditional clinical assessment of the cervix. The cervix of 50 specimens obtained consecutively at a series of total abdominal hysterectomies done for benign disease was evaluated for cervical consistency first by palpation preoperatively and then by the new device, using 5 prototypes, after the specimen was removed. Obtained results showed that intra-observer error for all five prototypes averaged 1.28 ± 2.5% (mean ± standard deviation), whereas inter-observer error was 8.44 ± 7.9%. Stratified by clinical cervical consistency as soft, moderate and firm, there was a statistically significant difference in the resistance to electrical current (f = 29.0, r2 = 0.19, p < 0.0001). Resistance to electrical current was highest for firm cervices, less for those of moderate consistency, and least for soft ones (21.8 ± 2.73, 19.6 ± 2.91 and 15.6 ± 4.09 ohms, respectively). In conclusion, measurements of cervical resistance obtained objectively by a new device reliably correlated with traditional clinical assessment of cervical consistency.

:
Published Online: 2005-06-01
Published in Print: 2002-09-26

Copyright © 2002 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. Editorial
  2. The odds of delivering one, two or three extremely low birth weight (<1000 g) triplet infants: a study of 3288 sets
  3. Evaluation of a device for objective determination of cervical consistency: A pilot study of devices validity on uterine specimens obtained by total abdominal hysterectomy for benign uterine disease
  4. Clinical risk factors for deep venous thrombosis in pregnancy and the puerperium
  5. Waterbirth: water temperature and bathing time mother knows best!
  6. Anal sphincter injury during vaginal delivery – an argument for cesarean section on request?
  7. Doppler sonography of uterine arteries at 20–23 weeks: risk assessment of adverse pregnancy outcome by quantification of impedance and notch
  8. Cadmium concentration in maternal and cord blood and infant birth weight: a study on healthy non-smoking women
  9. The effects of oral carbohydrate administration on fetal acid base balance
  10. Labor induction and meconium: in vitro effects of oxytocin, dinoprostone and misoprostol on rat ileum relative to myometrium
  11. Catch-up growth in fetal malnourished term infants
  12. Role of surfactant inhibitors in amniotic fluid in respiratory distress syndrome
  13. Congenital tuberculosis proven by percutaneous liver biopsy: report of a case
  14. A case of peripartum cardiomyopathy with a transient increase of plasma interleukin-6 concentration occurred following mirror syndrome
  15. Bilateral cystic adenomatoid lung malformation type III – a rare differential diagnosis of pulmonary hypertension in neonates
  16. An unexpected case of primary pulmonary hypertension of the neonate (PPHN). Potential role of topical administration of enoxolone
  17. Urethral catheterization in neonates – how far is too far?
  18. Congress Calendar
Downloaded on 31.12.2025 from https://www.degruyterbrill.com/document/doi/10.1515/JPM.2002.056/html
Scroll to top button