Biochemical and molecular investigation of two Korean patients with glycogen storage disease type III
-
Sue-Hyun Oh
Abstract
Background: Glycogen storage disease type III (GSD-III) is an inborn error of glycogen metabolism caused by a deficiency of the glycogen debranching enzyme, amylo-1,6-glucosidase,4-α-glucanotransferase (AGL). Here, we describe two unrelated Korean patients with GSD-III and review their clinical and laboratory findings.
Methods: The patients were 18- and 11-month-old girls. They presented with hepatosplenomegaly, developmental delay and hypotonia. The routine laboratory findings showed an elevated serum aspartate aminotransferase, alanine aminotransferase, creatine kinase and triglyceride levels. The blood lactate and uric acid levels were within normal limits. PCR and direct sequencing were performed to determine genetic findings.
Results: Glycogen quantitation was markedly increased and AGL activity was undetectable in both patients. Sequence analysis of the AGL gene showed that both patients were compound heterozygotes for c.853C>T (p.R285X) and c.1735+1G>T in one patient, and c.2894_2896delGGAinsTG and c.4090G>C (p.D1364H) in the other patient. The c.2894_2896delGGAinsTG and c.4090G>C (p.D1364H) mutation was a novel finding.
Conclusions: GSD-III should be ruled out when a patient presents with hepatic abnormalities, hypoglycemia, myopathy and hyperlipidemia. This is the first report of confirmation of GSD-III in Korean patients by biochemical and genetic findings.
Clin Chem Lab Med 2008;46:1245–9.
©2008 by Walter de Gruyter Berlin New York
Articles in the same Issue
- Review
- Application of spin label electron paramagnetic resonance in the diagnosis and prognosis of cancer and sepsis
- Opinion Papers
- Local regression: a new approach for measurement system comparison analysis
- Accuracy in clinical chemistry – who will kiss Sleeping Beauty awake?
- A practical approach to instrument selection, evaluation, basic financial management and implementation in pathology and research
- Genetics and Molecular Diagnostics
- Fetal hemoglobin: assessment of glycation and acetylation status by electrospray ionization mass spectrometry
- Preliminary validation of real-time PCR assays for the identification of Yersinia pestis
- Biochemical and molecular investigation of two Korean patients with glycogen storage disease type III
- Are microarrays useful in the screening of ABCA4 mutations in Italian patients affected by macular degenerations?
- General Clinical Chemistry and Laboratory Medicine
- Quantification of vascular endothelial growth factor, interleukin-8, and basic fibroblast growth factor in plasma of cancer patients and healthy volunteers – comparison of ELISA and microsphere-based multiplexed immunoassay
- Low serum vitamin B12 is associated with recurrent pregnancy loss in Syrian women
- Allantoin as a marker of oxidative stress in human erythrocytes
- Diagnostic performance of rapid tests for detection of fecal calprotectin and lactoferrin and their ability to discriminate inflammatory from irritable bowel syndrome
- Measurement of mycophenolic acid in plasma or serum by a commercial enzyme inhibition technique in comparison with a high performance liquid chromatography method
- Use of the TLX ultracentrifuge for the isolation of different density lipoproteins and effects of freeze/thawing of human plasma before ultracentrifugation
- Comprehensive profiling of the human circulating endocannabinoid metabolome: clinical sampling and sample storage parameters
- Reference Values and Biological Variations
- Reference ranges for neuroprotein S-100B: from infants to adolescents
- Variability in longitudinal cerebrospinal fluid tau and phosphorylated tau measurements
- Reference intervals for thyreotropin and thyroid hormones for healthy adults based on the NOBIDA material and determined using a Modular E170®
- Influence of acute physical exercise on emerging muscular biomarkers
- Guidelines and Recommendations
- Trueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement. An international study in the framework of the EC4 creatinine standardization working group
- Letters to the Editor
- What's in a name? Standardisation of HbA1c: a response
- Choice of sample for the analysis of circulating angiogenic cytokines
- Plasminogen activator inhibitor-1 (PAI-1), toll-like receptor 4 (TLR4), factor II (FII), FXIII and fibrinogen polymorphisms are not associated with the prevalence of sudden death due to ventricular fibrillation during myocardial infarction
- Spurious hypoglycemia caused by precipitation of a monoclonal immunoglobulin using the Modular P system glucose method
- Reporting growth hormone assay results in terms of one consensus recombinant standard preparation offers less than optimal reduction of between-method variation
- SI or non-SI units – which better match day-to-day imprecision?
- Results of hemolyzed samples can be useful
- Inter-laboratory survey of erythrocyte free protoporphyrin quantification – announcement of a pilot study
- Bacterial contamination positively interferes with β-glucosidase and hexosaminidase assays in white blood cell lysates
- Abstracts
- Congress of Clinical Chemistry and Laboratory Medicine. 5th Annual Conference of the German United Society of Clinical Chemistry and Laboratory Medicine (DGKL), September 21–24, 2008, Mannheim, Germany
- SIBioC 2008 40th National Congress of the Italian Society of Clinical Biochemistry and Clinical Molecular Biology, October 28–31, 2008, Rimini, Italy
Articles in the same Issue
- Review
- Application of spin label electron paramagnetic resonance in the diagnosis and prognosis of cancer and sepsis
- Opinion Papers
- Local regression: a new approach for measurement system comparison analysis
- Accuracy in clinical chemistry – who will kiss Sleeping Beauty awake?
- A practical approach to instrument selection, evaluation, basic financial management and implementation in pathology and research
- Genetics and Molecular Diagnostics
- Fetal hemoglobin: assessment of glycation and acetylation status by electrospray ionization mass spectrometry
- Preliminary validation of real-time PCR assays for the identification of Yersinia pestis
- Biochemical and molecular investigation of two Korean patients with glycogen storage disease type III
- Are microarrays useful in the screening of ABCA4 mutations in Italian patients affected by macular degenerations?
- General Clinical Chemistry and Laboratory Medicine
- Quantification of vascular endothelial growth factor, interleukin-8, and basic fibroblast growth factor in plasma of cancer patients and healthy volunteers – comparison of ELISA and microsphere-based multiplexed immunoassay
- Low serum vitamin B12 is associated with recurrent pregnancy loss in Syrian women
- Allantoin as a marker of oxidative stress in human erythrocytes
- Diagnostic performance of rapid tests for detection of fecal calprotectin and lactoferrin and their ability to discriminate inflammatory from irritable bowel syndrome
- Measurement of mycophenolic acid in plasma or serum by a commercial enzyme inhibition technique in comparison with a high performance liquid chromatography method
- Use of the TLX ultracentrifuge for the isolation of different density lipoproteins and effects of freeze/thawing of human plasma before ultracentrifugation
- Comprehensive profiling of the human circulating endocannabinoid metabolome: clinical sampling and sample storage parameters
- Reference Values and Biological Variations
- Reference ranges for neuroprotein S-100B: from infants to adolescents
- Variability in longitudinal cerebrospinal fluid tau and phosphorylated tau measurements
- Reference intervals for thyreotropin and thyroid hormones for healthy adults based on the NOBIDA material and determined using a Modular E170®
- Influence of acute physical exercise on emerging muscular biomarkers
- Guidelines and Recommendations
- Trueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement. An international study in the framework of the EC4 creatinine standardization working group
- Letters to the Editor
- What's in a name? Standardisation of HbA1c: a response
- Choice of sample for the analysis of circulating angiogenic cytokines
- Plasminogen activator inhibitor-1 (PAI-1), toll-like receptor 4 (TLR4), factor II (FII), FXIII and fibrinogen polymorphisms are not associated with the prevalence of sudden death due to ventricular fibrillation during myocardial infarction
- Spurious hypoglycemia caused by precipitation of a monoclonal immunoglobulin using the Modular P system glucose method
- Reporting growth hormone assay results in terms of one consensus recombinant standard preparation offers less than optimal reduction of between-method variation
- SI or non-SI units – which better match day-to-day imprecision?
- Results of hemolyzed samples can be useful
- Inter-laboratory survey of erythrocyte free protoporphyrin quantification – announcement of a pilot study
- Bacterial contamination positively interferes with β-glucosidase and hexosaminidase assays in white blood cell lysates
- Abstracts
- Congress of Clinical Chemistry and Laboratory Medicine. 5th Annual Conference of the German United Society of Clinical Chemistry and Laboratory Medicine (DGKL), September 21–24, 2008, Mannheim, Germany
- SIBioC 2008 40th National Congress of the Italian Society of Clinical Biochemistry and Clinical Molecular Biology, October 28–31, 2008, Rimini, Italy