Home Recommendation for measuring and reporting chloride by ISEs in undiluted serum, plasma or blood: International Federation of Clinical Chemistry and Laboratory Medicine (IFCC): IFCC Scientific Division, Committee on Point of Care Testing and Working Group on Selective Electrodes
Article
Licensed
Unlicensed Requires Authentication

Recommendation for measuring and reporting chloride by ISEs in undiluted serum, plasma or blood: International Federation of Clinical Chemistry and Laboratory Medicine (IFCC): IFCC Scientific Division, Committee on Point of Care Testing and Working Group on Selective Electrodes

  • Mohammed C. Ben Rayana , Robert W. Burnett , Arthur K. Covington , Paul D'Orazio , Niels Fogh-Andersen , Ellis Jacobs , Ritu Kataky , Wolf R. Külpmann , Katsuhiko Kuwa , Lasse Larsson , Andrzej Lewenstam , Anton H.J. Maas , Gerhard Mager , Jerzy W. Naskalski , Anthony O. Okorodudu , Christoph Ritter and Andrew St John
Published/Copyright: September 21, 2011

Abstract

The proposed recommendation for measuring and reporting chloride in undiluted plasma or blood by ion-selective electrodes (ISEs) will provide results that are identical to chloride concentrations measured by coulometry for standardized normal plasma or blood samples. It is applicable to all current ISEs dedicated to chloride measurement in undiluted samples that meet the requirements. However, in samples with reduced water concentration, results by coulometry are lower than by ion-selective electrode due to volume displacement. The quantity measured by this standardized ISE procedure is called the ionized chloride concentration. It may be clinically more relevant than the chloride concentration as determined by coulometry, photometry or by ISE after dilution of the sample.


Corresponding author: Prof. Dr. W.R. Külpmann, Klinische Chemie, Medizinische Hochschule Hannover, Carl-Neuberg-Str, 1, 30625 Hannover, Germany Phone: +49-5115326613, Fax: +49-5115328614,

References

1. Burnett RW, Covington AK, Fogh-Andersen N, Külpmann WR, Lewenstam A, Maas AH, et al. Use of ion-selective electrodes for blood-electrolyte analysis. Recommendations for nomenclature, definitions and conventions. IFCC, 1997; 9:16–22, Clin Chem Lab Med 2000; 38:363–70.Search in Google Scholar

2. Burnett RW, Covington AK, Fogh-Andersen N, Külpmann WR, Lewenstam A, Maas AH, et al. Recommendations for measurement of and conventions for reporting sodium and potassium by ion-selective electrodes in undiluted serum, plasma or whole blood. Clin Chem Lab Med 2000; 38:1065–71.10.1515/CCLM.2000.159Search in Google Scholar

3. Bates RG. Determination of pH, 2nd ed. New York: John Wiley & Sons, 1973:31–58.Search in Google Scholar

4. Maas AH. pH determination of body fluids with a micro glass electrode and a saturated KCl bridge in the cell. Clin Chim Acta 1970; 28:373–90.10.1016/0009-8981(70)90062-8Search in Google Scholar

5. Siggaard-Andersen O, Fogh-Andersen N. The erythrocyte effect on the liquid junction potential: an osmotic dilution phenomenon. In: Maas AH, Buckley B, Manzoni A, Moran RF, Siggaard-Andersen O, Sprokholt R, editors. Methodology and clinical applications of ion selective electrodes. IFCC Workshop, Stresa 1988. Utrecht: Elinkwijk, 1989:335–41.Search in Google Scholar

6. Morf WE. The principles of ion-selective electrodes and of membrane transport. Amsterdam: Elsevier, 1981.Search in Google Scholar

7. Yajima S, Tohda K, Buhlmann P, Umezawa Y. The Donnan exclusion failure of neutral ionophore-based ion-selective electrodes studied by optical second-harmonic generation. Anal Chem 1997; 69:1919–24.10.1021/ac961315tSearch in Google Scholar

8. Buck RP, Toth K, Graf E, Horvai G, Pungor E. Donnan exclusion failure in low anion site density membranes containing valinomycin. J Electroanal Chem 1987; 223:51–66.10.1016/0022-0728(87)85250-6Search in Google Scholar

9. Tohda K, Higuchi T, Dragoe D, Umezawa Y. Threshold ionic site concentrations required for Nernstian potentiometric responses of neutral ionophore-incorporated ion-selective liquid membrane. Anal Sci 2001; 17:833–9.10.2116/analsci.17.833Search in Google Scholar

10. NIST. A reference method for the determination of chloride in serum, NBS Special Publication 260-67. Washington, DC: NIST, 1979.Search in Google Scholar

11. de Jong GM, Huizinga JR, Wolthers BG, Jansen HG, Uges DR, Hindriks FR, et al. Comparison of the precision of seven analytical methods for the H2O concentration in human serum and urine. Clin Chim Acta 1987; 166:187–94.10.1016/0009-8981(87)90421-9Search in Google Scholar

12. Dujardin CG, Roijers AF. Preparation of an optically clear frozen human control serum. Scand J Clin Lab Invest 1984; 45:569–72.Search in Google Scholar

Published Online: 2011-9-21
Published in Print: 2006-3-1

©2006 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Recent advances in physiological calcium homeostasis
  2. Associations of apolipoprotein E exon 4 and lipoprotein lipase S447X polymorphisms with acute ischemic stroke and myocardial infarction
  3. Association of angiotensin II type 1 receptor gene polymorphism with carotid atherosclerosis
  4. Comparison of the TaqMan and LightCycler systems in pharmacogenetic testing: evaluation of CYP2C9*2/*3 polymorphisms
  5. Urinary cystatin C as a specific marker of tubular dysfunction
  6. Time-resolved fluorimetric immunoassay of calprotectin: technical and clinical aspects in diagnosis of inflammatory bowel diseases
  7. Direct and fast determination of antiretroviral drugs by automated online solid-phase extraction-liquid chromatography-tandem mass spectrometry in human plasma
  8. Markers of oxidative stress in children with Down syndrome
  9. Influence of hemolysis on routine clinical chemistry testing
  10. C-Reactive protein and neopterin levels in healthy non-obese adults
  11. Comparison of the lipid profile and lipoprotein(a) between sedentary and highly trained subjects
  12. Clinical outcome estimates based on treatment target limits of laboratory tests: proposal for a plot visualizing effects and differences of medical target setting exemplified by glycemic control in diabetes
  13. Metrological traceability of values for catalytic concentration of enzymes assigned to a calibration material
  14. Evaluation of a new Sebia kit for analysis of hemoglobin fractions and variants on the Capillarys® system
  15. Recommendation for measuring and reporting chloride by ISEs in undiluted serum, plasma or blood: International Federation of Clinical Chemistry and Laboratory Medicine (IFCC): IFCC Scientific Division, Committee on Point of Care Testing and Working Group on Selective Electrodes
  16. Diluent Multiassay for the MODULAR ANALYTICS E170 does not improve TSH dilutions compared to Diluent Universal
Downloaded on 4.10.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2006.060/html
Scroll to top button