Home Guidelines for blood smear preparation and staining procedure for setting up an external quality assessment scheme for blood smear interpretation. Part I: control material
Article
Licensed
Unlicensed Requires Authentication

Guidelines for blood smear preparation and staining procedure for setting up an external quality assessment scheme for blood smear interpretation. Part I: control material

  • Juan-Lluis Vives Corrons , Stephanie Albarède , George Flandrin , Silke Heller , Katalin Horvath , Berend Houwen , Gunnar Nordin , Erika Sarkani , Milan Skitek , Marjan Van Blerk and Jean-Claude Libeer
Published/Copyright: June 1, 2005

Abstract

Blood smear analysis is a well known technique in medical laboratories. Clinical relevance of this analysis and its interpretation are very important. Consequently, monitoring of laboratory performance by an external quality assessment scheme is strongly recommended. Most starting external quality organizers set up a scheme for clinical chemistry. Due to a lack of guidance documents, many organizers are reluctant to offer a hematology scheme. This article aims to be a very practical guidance document for external quality assessment organizers for the set up of blood smear schemes.


Corresponding author: Jean-Claude Libeer, Clinical Biology Department, Scientific Institute of Public Health, Juliette Wytsmanstraat 14, 1050 Brussels, Belgium. Phone: +32 2 642 55 27, Fax: +32 2 642 56 45, E-mail:

References

1 National Committee for Clinical Laboratory Standards. Reference leukocyte differential count (proportional) and evaluation of instrumental methods. Villanova, PA: NCCLS approved standard document H20-A, 1992.Search in Google Scholar

2 Lewis SM. Blood film evaluations as a quality control activity. Clin Lab Haematol 1990; 12(Suppl 1):119–27.Search in Google Scholar

3 Bentley SA. Quality control and the differential leukocyte count. Clin Lab Haematol 1990; 12(Suppl 1):101–9.Search in Google Scholar

4 Houwen B. Blood film preparation and staining procedures. In: Pierre RV, editor. Clinics in laboratory medicine. Philadelphia: Saunders, 2002;22:1–14.Search in Google Scholar

5 National Committee for Clinical Laboratory Standards. Evacuated tubes and additives for blood specimen collection. Villanova, PA: NCCLS approved standard document H1–A4, 1996.Search in Google Scholar

6 National Committee for Clinical Laboratory Standards. Devices for collection of skin puncture blood specimens. Villanova, PA: NCCLS approved guideline document H14–A2, 1990.Search in Google Scholar

7 National Committee for Clinical Laboratory Standards. Procedures for the collection of diagnostic blood specimens by venipuncture. Villanova, PA: NCCLS approved standard document H3–A4, 1998.Search in Google Scholar

8 National Committee for Clinical Laboratory Standards. Procedures for the collection of diagnostic blood specimens by skin puncture. Villanova, PA: NCCLS approved standard document H4–A3, 1991.Search in Google Scholar

9 Bonte HA, Hoorn RKJ. Recommendations for the procedure and terminology of the microscopic examination of peripheral blood. Society for Hematological Laboratory Diagnostics, 1990Search in Google Scholar

10 International Council for Standardization in Hematology (ICSH). Recommendations of the ICSH for EDTA anticoagulation of blood for blood cell counting and sizing. Am J Clin Pathol 1993; 100:371.10.1093/ajcp/100.4.371Search in Google Scholar PubMed

11 Dacie JV, Lewis SM. Practical haematology, 9th ed. Edinburgh, Scotland: Churchill Livingstone, 2001.Search in Google Scholar

12 Hull BP, Bakhiet N, Ryu J, Houwen B. Biohazard evaluation of laboratory hematology tests. Presented at the 7th International Symposium on Technological Innovations in Laboratory Hematology, Lake Tahoe, NV, 1994.Search in Google Scholar

13 Stiene-Martin EA. Causes for poor leukocyte distribution in manual spreader-slide blood films. Am J Med Technol 1980; 46:624–32.Search in Google Scholar

14 Born JW, Jelema G, Noordervliet R, Reymer F, Baelde HA, Paauwe J, et al. Improved performance of the automated slide preparation unit, Sysmex SP-100. Sysmex J Int 2000; 10:71–6.Search in Google Scholar

15 International Council for Standardization in Haematology (ICSH): ICSH reference method for staining of blood and bone marrow by azure B and eosin Y (Romanowsky stain). Br J Haematol 1984; 57:707–10.10.1111/j.1365-2141.1984.tb02949.xSearch in Google Scholar

16 Bennatar L, Flandrin G. Analyse morphométrique, coloration panoptique de May-Grundwald Giemsa et controle de qualité. Annales du Contrôle National de Qualite (AFSSAPS/France) 1999; 16:157–69.Search in Google Scholar

Received: 2003-10-28
Accepted: 2004-4-19
Published Online: 2005-6-1
Published in Print: 2004-8-1

© Walter de Gruyter

Articles in the same Issue

  1. Rapid detection of the factor XIII Val34Leu (163 G→T) polymorphism by real-time PCR using fluorescence resonance energy transfer detection and melting curve analysis
  2. Changes of matrix metalloproteinases (MMPs) and tissue inhibitors of metalloproteinases (TIMPs) in the serum of patients with autoimmune diseases: association with age and disease activity
  3. A recombinant cell bioassay for measurement of overall estrogenic activity of serum: preliminary results in women with breast cancer
  4. N-terminal pro-atrial natriuretic peptide as a biochemical marker of long-term interventional success after radiofrequency catheter ablation of paroxysmal supraventricular tachyarrhythmias
  5. Preventing in vitro lipoperoxidation in the malondialdehyde-thiobarbituric assay
  6. Oxidative stress: potential of distinct peroxide determination systems
  7. Quality assessment in cytogenetic and molecular genetic testing: the experience of the Italian Project on Standardisation and Quality Assurance
  8. Guidelines for blood smear preparation and staining procedure for setting up an external quality assessment scheme for blood smear interpretation. Part I: control material
  9. Measurement of serum and plasma osmolality in healthy young humans – influence of time and storage conditions
  10. High in-hospital mortality of intensive care patients with nucleated red blood cells in blood
  11. Frequency of –163 C > A and 63 C > G single nucleotide polymorphism of cytochrome P450 1A2 in two African populations
  12. Long-term stability of endogenous B-type natriuretic peptide (BNP) and amino terminal proBNP (NT-proBNP) in frozen plasma samples
  13. Plasma or serum samples: measurements of cardiac troponin T and of other analytes compared
  14. Antioxidant capacity of the human pericardial fluid: does gender have a role?
  15. Comparison of serum digoxin concentration monitoring by fluorescence polarization immunoassay on the TDxFLx® and dry chemistry enzyme immunoassay on the Vitros 950
  16. Multicenter analytical performance evaluation of the Elecsys® proBNP assay
  17. Analytical evaluation and reference values of serum amyloid-A on the BN ProSpec
  18. Reference values of soluble interleukin-2 receptor on the IMMULITE
  19. Analysis of cystatin C, creatinine, albumin, lipids and lipoprotein concentrations in serum and acidified citrate plasma (Stabilyte™) tubes compared
  20. Analysis of γ-globulins consisting of hepatitis C-associated cryoglobulins in the blood
  21. Serum total glutathione-S-transferase in stroke, a preliminary report
  22. Santorini Biologie Prospective Conference 2004 “From Human Genetic Variations to Prediction of Risks and Responses to the Environment”, Santorini, Greece, September 30–October 4, 2004
Downloaded on 22.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2004.149/html
Scroll to top button