Linearity evaluation of analytical methods that count particles
-
Robert T. Magari
Abstract
Linearity evaluation of an analytical method is important for both manufacturers of diagnostic devices and laboratory users. Some of the statistical assumptions for estimation and testing in linear regression are violated in analytical methods that count particles per unit of volume or/and time, leading to potential erroneous evaluation of linearity. The objective of this paper is to provide an approach for evaluating linearity in these cases. The number of counts for each concentration level has a Poisson probability distribution that is linear, second-, or higher-order polynomial function of the concentration. Maximum likelihood approach is used to estimate the parameters of the models. Deviance of a particular model and the likelihood ratio test are used to test for linearity. An evaluation of linearity of an analytical method in multiple experiments is also described. No particular changes to the standard testing protocols and data collections are necessary. There are several statistical software packages that can perform the calculations. Formulas and SAS codes presented in this article can also assist in estimation and statistical testing.
Copyright © 2004 by Walter de Gruyter GmbH & Co. KG
Articles in the same Issue
- Matrix metalloproteinases, inflammation and atherosclerosis: therapeutic perspectives
- Regulation of inflammatory responses by activated protein C: the molecular mechanism(s) and therapeutic implications
- Increased serum maternal levels of the HER2 oncoprotein p105 ectodomain in preeclampsia
- Determination of urinary glyoxal and methylglyoxal by high-performance liquid chromatography
- Antioxidants in patients with hyperthyroidism
- Biochemical diagnosis of impaired left ventricular ejection fraction - comparison of the diagnostic accuracy of brain natriuretic peptide (BNP) and amino terminal proBNP (NT-proBNP)
- Autoantibodies against oxidized low-density lipoprotein (ox-LDL) and LDL oxidation status
- Concomitant isolation of protein C inhibitor and unnicked β2-glycoprotein I
- Decreased expression of the insulin-like growth factor-I-binding protein-1 (IGFBP-1) phosphoisoform in pre-eclamptic Wharton's jelly and its role in the regulation of collagen biosynthesis
- Urine albumin excretion in acute ischaemic stroke is related to serum interleukin-6
- Diagnostic use of cerebral and extracerebral oxysterols
- Immunoglobulin G Fcγ receptor expression on polymorphonuclear cells in bronchoalveolar lavage fluid of HIV-infected and HIV-seronegative patients with bacterial pneumonia
- The discordance rate, a new concept for combining diagnostic decisions with analytical performance characteristics. 2. Defining analytical goals applied to the diagnosis of type 2 diabetes by blood glucose concentrations
- Effects of some pre-analytical conditions on the measurement of homocysteine and cysteine in plasma
- Testing and validating a homogeneous immunometric assay for interference
- Linearity evaluation of analytical methods that count particles
- Environmental dichlorodiphenyltrichlorethane or hexachlorobenzene exposure and breast cancer: is there a risk?
- Analytical performance and method comparison study of the total homocysteine fluorescence polarization immunoassay (FPIA) on the AxSYM analyzer
- Distribution of low-density lipoprotein particle size in healthy Korean adult males
- Management of invalid internal controls in the Cobas Amplicor HCV-RNA test using the high-speed centrifugation method
- The phenomenon of regression-toward-the-mean
- Error messages when calculating chi-square statistics with Microsoft EXCEL®
- Meetings and Awards
Articles in the same Issue
- Matrix metalloproteinases, inflammation and atherosclerosis: therapeutic perspectives
- Regulation of inflammatory responses by activated protein C: the molecular mechanism(s) and therapeutic implications
- Increased serum maternal levels of the HER2 oncoprotein p105 ectodomain in preeclampsia
- Determination of urinary glyoxal and methylglyoxal by high-performance liquid chromatography
- Antioxidants in patients with hyperthyroidism
- Biochemical diagnosis of impaired left ventricular ejection fraction - comparison of the diagnostic accuracy of brain natriuretic peptide (BNP) and amino terminal proBNP (NT-proBNP)
- Autoantibodies against oxidized low-density lipoprotein (ox-LDL) and LDL oxidation status
- Concomitant isolation of protein C inhibitor and unnicked β2-glycoprotein I
- Decreased expression of the insulin-like growth factor-I-binding protein-1 (IGFBP-1) phosphoisoform in pre-eclamptic Wharton's jelly and its role in the regulation of collagen biosynthesis
- Urine albumin excretion in acute ischaemic stroke is related to serum interleukin-6
- Diagnostic use of cerebral and extracerebral oxysterols
- Immunoglobulin G Fcγ receptor expression on polymorphonuclear cells in bronchoalveolar lavage fluid of HIV-infected and HIV-seronegative patients with bacterial pneumonia
- The discordance rate, a new concept for combining diagnostic decisions with analytical performance characteristics. 2. Defining analytical goals applied to the diagnosis of type 2 diabetes by blood glucose concentrations
- Effects of some pre-analytical conditions on the measurement of homocysteine and cysteine in plasma
- Testing and validating a homogeneous immunometric assay for interference
- Linearity evaluation of analytical methods that count particles
- Environmental dichlorodiphenyltrichlorethane or hexachlorobenzene exposure and breast cancer: is there a risk?
- Analytical performance and method comparison study of the total homocysteine fluorescence polarization immunoassay (FPIA) on the AxSYM analyzer
- Distribution of low-density lipoprotein particle size in healthy Korean adult males
- Management of invalid internal controls in the Cobas Amplicor HCV-RNA test using the high-speed centrifugation method
- The phenomenon of regression-toward-the-mean
- Error messages when calculating chi-square statistics with Microsoft EXCEL®
- Meetings and Awards