Home Profiling and in vivo Quantification of Proteins by High Resolution Mass Spectrometry: The Example of Goserelin, an Analogue of Luteinizing Hormone-Releasing Hormone
Article
Licensed
Unlicensed Requires Authentication

Profiling and in vivo Quantification of Proteins by High Resolution Mass Spectrometry: The Example of Goserelin, an Analogue of Luteinizing Hormone-Releasing Hormone

  • Sophie Michalet , Philippe Favreau and Reto Stöcklin
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 41 Issue 12

Abstract

Proteins are essential biomolecules which are frequently involved in major pathological syndromes and are widely used as diagnostic markers or therapeutic agents. The emergence of proteomics will doubtless further increase the significance of proteins both in the clinic and in the life sciences in general. Our main objective is to offer innovative solutions to what we like to call the “post-proteomics era”. To achieve our goal, we intend to develop novel approaches and technologies for in vivo metabolic studies of proteins using mass spectrometry (MS), focusing on pharmacokinetics and pharmacodynamics. Using goserelin as a model, we have successfully developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of an intact analogue of luteinizing hormone-releasing hormone (LHRH) in small volumes of rat plasma samples at concentrations ranging from 0.3 to 405.0 μg/l. To this end, a microbore reversed-phase-HPLC system was coupled on-line to a tandem high resolution quadrupole time-of-flight (Q-TOF) instrument fitted with an electrospray ion source and operated in LC-MS/MS mode. External calibration was used and the high resolution was crucial to discard contaminating signals, which would not have been possible with the more conventional triple quadrupole mass spectrometers operated in a static mode. For low sample amounts, calibration curves were constructed corresponding to rat plasma levels of 0.3 to 16.4 μg/l and found to be of third order with a coefficient of determination greater than 0.999. The relative standard deviation was found to be lower than 15%. A lower limit of detection (LLOD) of 0.17 μg/l and a lower limit of quantification (LLOQ) of 0.3 μg/l were determined.

:
Published Online: 2005-06-01
Published in Print: 2003-12-04

Copyright © 2003 by Walter de Gruyter GmbH & Co. KG

Downloaded on 12.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2003.242/html
Scroll to top button