Home Effect of Different Dialysis Membranes on Erythrocyte Antioxidant Enzyme Levels and Scavenger Systems Related to Free Hemoglobin in Serum of Hemodialysis Patients
Article
Licensed
Unlicensed Requires Authentication

Effect of Different Dialysis Membranes on Erythrocyte Antioxidant Enzyme Levels and Scavenger Systems Related to Free Hemoglobin in Serum of Hemodialysis Patients

  • Ilza Salamunić , Dubravka Juretić and Dragan Ljutić
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 41 Issue 7

Abstract

The main objective of the present study was to analyze some aspects of the function and structure of erythrocytes with respect to hemodialysis membrane biocompatibility throughout the erythrocyte and serum antioxidant levels. The study included 36 hemodialysis patients (14 female and 22 male, age 22–79 years, median 55) treated at the Department of Nephrology and Dialysis, Split Clinical Hospital in Split, and 30 control subjects matched for age and sex. Hemodialysis was performed three times a week for 4 hours with cellulose diacetate (n = 17; 6 females and 11 males) or polysulfone (n = 19; 8 females and 11 males) membranes. The aim of the study was to assess the level of oxidative stress in these patients by measuring catalytic concentrations of superoxide dismutase and glutathione peroxidase in erythrocyte lysate and scavenger systems related to free hemoglobin in serum (haptoglobin, hemopexin and bilirubin). In comparison with control values, the mean catalytic concentrations of superoxide dismutase were increased and catalytic concentrations of glutathione peroxidase decreased in patients before hemodialysis irrespective of the membrane used. Immediately after hemodialysis with either membrane, the mean catalytic concentrations of superoxide dismutase returned to the control range, while those of glutathione peroxidase were still decreased compared to control values, without any significant difference between the cellulose diacetate and polysulfone membranes. The predialysis and postdialysis values of haptoglobin, hemopexin and bilirubin in patient sera were within the range of control values. Comparison of the cellulose diacetate and polysulfone membranes showed no significant differences in the erythrocyte content of antioxidant enzymes and the scavenger system related to free hemoglobin in serum before and after hemodialysis.

:
Published Online: 2005-06-01
Published in Print: 2003-07-21

Copyright © 2003 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. 18th ICCC 2002 Kyoto
  2. Essential Hypertension: Genes and Dreams
  3. Alteration of Nucleotide Metabolism: A New Mechanism for Mitochondrial Disorders
  4. Tryptophan Metabolites and Brain Disorders
  5. The Role of Interleukin-4 and Interleukin-13 in the Non-Immunologic Aspects of Asthma Pathogenesis
  6. Soluble Guanylyl Cyclase: Physiological Role as an NO Receptor and the Potential Molecular Target for Therapeutic Application
  7. The Increasing Impact of Laboratory Medicine on Clinical Cardiology
  8. Conveying the Importance of the Preanalytical Phase
  9. Polymorphisms in the IL-4 and IL-4R [α] Genes and Allergic Asthma
  10. Circulating Transforming Growth Factor-β1, Lipoprotein(a) and Cellular Adhesion Molecules in Angiographically Assessed Coronary Artery Disease
  11. Balance of Pro- and Anti-Inflammatory Cytokines in Liver Surgery
  12. Effect of Different Dialysis Membranes on Erythrocyte Antioxidant Enzyme Levels and Scavenger Systems Related to Free Hemoglobin in Serum of Hemodialysis Patients
  13. Fluorometric Assays of Phospholipase A2 Activity with Three Different Substrates in Biological Samples of Patients with Schizophrenia
  14. Determination of Itraconazole and Hydroxyitraconazole in Plasma by Use of Liquid Chromatography-Tandem Mass Spectrometry with On-line Solid-Phase Extraction
  15. High-Throughput Liquid Chromatography-Tandem Mass Spectrometric Analysis of Sirolimus in Whole Blood
  16. Prevention of Biochemical Changes in γ-Irradiated Rats by Some Metal Complexes
  17. Endocrine Alterations in the Aging Male
  18. Clinical Evaluation of Nine Free Thyroxine Assays: Persistent Problems in Particular Populations
  19. Immunoturbidimetric Determination of C-Reactive Protein (CRP) and High-Sensitivity CRP on Heparin Plasma. Comparison with Serum Determination
  20. Problems of Comparing Blood Glucose Molality and Molarity Determined with an Omni, an EML 105 and an Ebio Analyser
  21. Validation of an Automated Immunoturbidimetric Assay for Measurement of Plasma D-Dimer
  22. The Late Greco-Roman and Byzantine Contribution to the Evolution of Laboratory Examinations of Bodily Excrement. Part 1: Urine, Sperm, Menses and Stools
  23. Reference Interval for Lactate Dehydrogenase Catalytic Activity in Serum Measured According to the New IFCC Recommendations
  24. State-of-the-Art Systematic Error for Biochemical Quantities with Universal Cut-off Values or Universal Reference Limits
  25. Meetings and Awards
Downloaded on 12.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2003.137/html
Scroll to top button