Home Determination of Glycerol in Plasma by an Automated Enzymatic Spectrophotometric Procedure
Article
Licensed
Unlicensed Requires Authentication

Determination of Glycerol in Plasma by an Automated Enzymatic Spectrophotometric Procedure

  • Rong Li , Bart Keymeulen and Erik Gerlo
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 39 Issue 1

Abstract

The plasma concentration of glycerol, the backbone of triglycerides and the end product of triacylglycerol breakdown, is considered to reflect lipolysis in adipose tissue. We evaluated an automated enzymatic procedure for the measurement of glycerol in plasma. The assay was linear up to 250μmol/l. The detection limit was 8μmol/l. Recovery averaged 94% from spiked plasma and 104% from diluted plasma. An extensive precision study performed according to the guidelines of the National Committee for Clinical Laboratory Standards showed within-run coefficients of variation between 14.8% and 2.6% for concentrations ranging from 28μmol/l to 164 μmol/l. The reference range for fasting healthy adult men was 14–69 μmol/l. Glycerol levels were significantly correlated with free fatty acid levels. This automated enzymatic method is rapid and reliable, and provides greater sensitivity or convenience than previously described procedures.

:
Published Online: 2005-06-01
Published in Print: 2001-02-21

Copyright © 2001 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. Editorial
  2. Polymorphisms in the Apolipoprotein E Gene Regulatory Region in Relation to Coronary Heart Disease and Their Effect on Plasma Apolipoprotein E
  3. Further Characterization of Serum Amyloid A4 as a Minor Acute Phase Reactant and a Possible Nutritional Marker
  4. Determination of Human Angiotensin Converting Enzyme (ACE) Gene Polymorphisms in Erectile Dysfunction: Frequency Differences of ACE Gene Polymorphisms according to the Method of Analysis
  5. Simple Gas Chromatography Analysis of Faecal Butyrate: Application to Patients at Risk of Pouchitis
  6. Determination of Glycerol in Plasma by an Automated Enzymatic Spectrophotometric Procedure
  7. Clinical Applications of the 2nd Generation Assay for Anti-TSH Receptor Antibodies in Graves' Disease. Evaluation in Patients with Negative 1st Generation Test
  8. The Clinical Value of Microtransferrinuria and Microalbuminuria in the Prediction of Pre-eclampsia
  9. A Non-Icteric Cholecystectomized Patient with Recurrent Attacks of Right Epigastric Pain and Dilated Common Bile Duct – Do Liver Function Tests Predict Bile Duct Stones?
  10. Serum Lactate Dehydrogenase Isoenzyme 1 and Prediction of Death in Patients with Metastatic Testicular Germ Cell Tumors
  11. Annual Rhythmic and Non-Rhythmic Biological Variation of Magnesium and Ionized Calcium Concentrations
  12. Unit-Independent Reporting of Laboratory Test Results
  13. Analysis of Large and Small Samples of Biochemical and Clinical Data.
  14. Evaluation of Five Commercial Enzyme Immunoassays for the Detection of Human Cytomegalovirus-Specific IgM Antibodies in the Absence of a Commercially Available Gold Standard
  15. Alkaline Phosphatase Activity: New Assay for the Reflotron® System. Results of the Evaluation in Eight Clinical Laboratories
  16. Report on the 4th Estonian Summer School of Laboratory Medicine
  17. Laboratory-Related Measures of Patient Outcomes: An Introduction. Edited by Michael G. Bissell
  18. Report from the 50th Anniversary Congress of the Hungarian Society of Clinical Pathology and from the Executive Board Meeting of FESCC in Debrecen (Hungary)
  19. Report from the 8th Meeting of the Balkan Clinical Laboratory Federation
Downloaded on 23.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2001.006/html
Scroll to top button