Evaluation of the ADVIA® Centaur™ TSH-3 Assay

  • Michael Vogeser , Michael Weigand , Peter Fraunberger , Heike Fischer and Peter Cremer
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 38 Issue 4

Abstract

An analytical evaluation of the thyroid stimulating hormone (TSH-3) assay on the Bayer ADVIA® CentaurTM immunoassay system was performed. General analytical requirements (linearity, resistance to typical interferences, absence of a carry-over effect) were fulfilled and reproducibility was satisfactory. Inter-assay coefficient of variation (CV) of a human serum pool with a concentration of 0.014 mU/l was 22.3%; at concentrations between 0.26 and 83 mU/l CV was below 6%. Method comparison study demonstrated close agreement of TSH results compared to those obtained with the Roche Elecsys® 2010 TSH assay (ADVIA Centaur = 1.08 × Elecsys−0.18 mU/l; r=0.987; n=324). Handling and practicability of the ADVIA Centaur system proved to be convenient with a very high sample throughput. We conclude that the ADVIA Centaur TSH-3 assay meets requirements for clinical use.

:
Published Online: 2005-06-01
Published in Print: 2000-04-30

Copyright © 2000 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. The Clinical Usefulness of the Measurement of Cytokines
  2. Measurement of Cholesterol and other Lipoprotein Constituents in the Clinical Laboratory
  3. Serum ras (p21) as a Marker for Occupationally Derived Lung Cancer?
  4. Macro Lactate Dehydrogenase in a Patient with Myocarditis
  5. Elimination of Serum Complexed Prostate-Specific Antigen after Radical Retropubic Prostatectomy
  6. Suitability of Collection Tubes with Separator Gels for Collecting and Storing Blood Samples for Therapeutic Drug Monitoring (TDM)
  7. Influence of in vivo Hemoglobin Carbamylation on HbA1c Measurements by Various Methods
  8. Comparison of the Abbott IMx® and a High-Performance Liquid Chromatography Method for Measuring Total Plasma Homocysteine
  9. Evaluation of the ADVIA® Centaur™ TSH-3 Assay
  10. Biochemical Composition and Electrolyte Balance of "Unstimulated" Whole Human Saliva
  11. Evaluation of a New Simple and Rapid Enzyme-Linked Immunosorbent Assay Kit for Neopterin Determination
  12. Analytical and Clinical Evaluation of Troponin I Determination on Dimension RXL-HM
  13. Use of Ion-Selective Electrodes for Blood-Electrolyte Analysis. Recommendations for Nomenclature, Definitions and Conventions
  14. FESCC Survey on Accreditation and Post-Graduate Training in Clinical Chemistry in European Countries
  15. Clinical Use of Soluble Transferrin Receptor
  16. Macro Creatine Kinase Type 1: a Clinically Significant Marker?
  17. Vitamin B12 and B12-Proteins. By Bernhard Kräutler, Duilio Arigoni and Bernard T. Golding, editors
  18. The Bone and Mineral Manual – a Practical Guide. By Michael Kleerekoper, Ethel Sins, Michael McClung, editors
Downloaded on 11.10.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2000.048/html?lang=en
Scroll to top button