Home Evaluation of a New Simple and Rapid Enzyme-Linked Immunosorbent Assay Kit for Neopterin Determination
Article
Licensed
Unlicensed Requires Authentication

Evaluation of a New Simple and Rapid Enzyme-Linked Immunosorbent Assay Kit for Neopterin Determination

  • Jürgen Westermann , Frank Thiemann , Ludwig Gerstner , Franz Tatzber , Ivan Kozák , Thomas Bertsch and Christian Krüger
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 38 Issue 4

Abstract

A new commercially available enzyme-linked immunosorbent assay (ELISA) kit has been evaluated for the measurement of neopterin concentrations in serum, plasma and urine. This competitive ELISA is technically simple, requires only small sample volume and is rapid to perform. The assay procedure consists of sequential 1.5 h and 10 min room temperature incubation steps. The ELISA is accurate, sensitive, specific, and precise. Linear regression analysis of neopterin concentrations measured with the new ELISA and with an established method yielded a highly singificant correlation (r = 0.99). The new assay is applicable to ELISA workstations, thus enabling determination of neopterin in large series of samples. The neopterin ELISA kit has been used in routine laboratory testing of blood donations in a blood bank.

:
Published Online: 2005-06-01
Published in Print: 2000-04-30

Copyright © 2000 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. The Clinical Usefulness of the Measurement of Cytokines
  2. Measurement of Cholesterol and other Lipoprotein Constituents in the Clinical Laboratory
  3. Serum ras (p21) as a Marker for Occupationally Derived Lung Cancer?
  4. Macro Lactate Dehydrogenase in a Patient with Myocarditis
  5. Elimination of Serum Complexed Prostate-Specific Antigen after Radical Retropubic Prostatectomy
  6. Suitability of Collection Tubes with Separator Gels for Collecting and Storing Blood Samples for Therapeutic Drug Monitoring (TDM)
  7. Influence of in vivo Hemoglobin Carbamylation on HbA1c Measurements by Various Methods
  8. Comparison of the Abbott IMx® and a High-Performance Liquid Chromatography Method for Measuring Total Plasma Homocysteine
  9. Evaluation of the ADVIA® Centaur™ TSH-3 Assay
  10. Biochemical Composition and Electrolyte Balance of "Unstimulated" Whole Human Saliva
  11. Evaluation of a New Simple and Rapid Enzyme-Linked Immunosorbent Assay Kit for Neopterin Determination
  12. Analytical and Clinical Evaluation of Troponin I Determination on Dimension RXL-HM
  13. Use of Ion-Selective Electrodes for Blood-Electrolyte Analysis. Recommendations for Nomenclature, Definitions and Conventions
  14. FESCC Survey on Accreditation and Post-Graduate Training in Clinical Chemistry in European Countries
  15. Clinical Use of Soluble Transferrin Receptor
  16. Macro Creatine Kinase Type 1: a Clinically Significant Marker?
  17. Vitamin B12 and B12-Proteins. By Bernhard Kräutler, Duilio Arigoni and Bernard T. Golding, editors
  18. The Bone and Mineral Manual – a Practical Guide. By Michael Kleerekoper, Ethel Sins, Michael McClung, editors