On the selection of the nozzle geometry and other parameters for cutting corneal flaps with waterjets / Düsengeometrie und andere Parameter beim Wasserstrahlschneiden von Hornhautscheiben
-
Ricardo Cadavid
, Benedikt Jean and Dieter Wüstenberg
Abstract
A cutting waterjet to produce corneal flaps during refractive surgery or to slice donor corneas for corneal grafting was developed. Jets generated with several different nozzles were compared to determine the most appropriate nozzle geometry for this application. In this paper, it is also discussed how other variables, such as stand-off distance and transverse velocity, can affect the characteristics of the cut. The cutting mechanisms, giving bases for an application of waterjets for cutting other types of tissues, are also discussed.
Zusammenfassung
Es wurde ein Schneidewasserstrahl entwickelt, um Hornhautscheiben während refraktiver Augenchirurgie oder Hornhauttransplantationen zu schneiden. Wasserstrahlen, die mit verschiedenen Düsen erzeugt wurden, wurden miteinander verglichen, um die geeignetste Düsengeometrie für diese Anwendungen zu finden. Der vorliegende Artikel behandelt unter anderem, wie die Variabeln, z.B. der Abstand zwischen Arbeitsstück und Düse sowie die Vorschubgeschwindigkeit, die Eigenschaften des Schnittes beeinflussen können. Es werden auch verschiedene Schneidemechanismen erörtert und damit die Grundlage geschaffen zum Wasserstrahlschneiden anderer Gewebe.
©2009 by Walter de Gruyter Berlin New York
Articles in the same Issue
- Research articles
- Modeling of cardiac ischemia in human myocytes and tissue including spatiotemporal electrophysiological variations / Modellierung kardialer Ischämie in menschlichen Myozyten und Gewebe
- A two-class brain computer interface to freely navigate through virtual worlds / Ein Zwei-Klassen-Brain-Computer-Interface zur freien Navigation durch virtuelle Welten
- On the selection of the nozzle geometry and other parameters for cutting corneal flaps with waterjets / Düsengeometrie und andere Parameter beim Wasserstrahlschneiden von Hornhautscheiben
- Simulation of force loaded knee movement in a newly developed in vitro knee simulator / Simulation von belastungsabhängigen Kniebewegungen in einem neuartigen Knie-Simulator für In-vitro-Studien
- Biomechanische Studie zu vier winkelstabilen distalen palmaren Radiusplatten und einer nichtwinkelstabilen Radiusplatte: Steifigkeit und Versagenstests am Kadavermodell / Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model
Articles in the same Issue
- Research articles
- Modeling of cardiac ischemia in human myocytes and tissue including spatiotemporal electrophysiological variations / Modellierung kardialer Ischämie in menschlichen Myozyten und Gewebe
- A two-class brain computer interface to freely navigate through virtual worlds / Ein Zwei-Klassen-Brain-Computer-Interface zur freien Navigation durch virtuelle Welten
- On the selection of the nozzle geometry and other parameters for cutting corneal flaps with waterjets / Düsengeometrie und andere Parameter beim Wasserstrahlschneiden von Hornhautscheiben
- Simulation of force loaded knee movement in a newly developed in vitro knee simulator / Simulation von belastungsabhängigen Kniebewegungen in einem neuartigen Knie-Simulator für In-vitro-Studien
- Biomechanische Studie zu vier winkelstabilen distalen palmaren Radiusplatten und einer nichtwinkelstabilen Radiusplatte: Steifigkeit und Versagenstests am Kadavermodell / Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model