A two-class brain computer interface to freely navigate through virtual worlds / Ein Zwei-Klassen-Brain-Computer-Interface zur freien Navigation durch virtuelle Welten
-
Ricardo Ron-Angevin
, Antonio Díaz-Estrella and Francisco Velasco-Álvarez
Abstract
A brain computer interface that enables navigation through a virtual environment (VE) using four different navigation commands (turn right, turn left, move forward and move back) is presented. A graphical interface allows subjects to select a specific command. In this interface, the different navigation commands are surrounding a circle. A bar in the center of the circle is continuously rotating. The subject controls, by only two mental tasks, the bar extension to reach the chosen command. In this study, after an initial training based on three sessions, 8 out of 15 naive subjects were able to navigate through the VE discriminating between imagination of right-hand movements and relaxed state. All subjects (except one) improved their performance in each run and a mean error rate of 23.75% was obtained.
Zusammenfassung
Ein Brain-Computer-Interface, das die Navigation durch eine virtuelle Umwelt ermöglicht und dabei vier verschiedene Navigationskommandos (rechts drehen, links drehen, vorwärts oder rückwärts bewegen) benutzt, wird präsentiert. Ein grafisches Interface erlaubt den Probanden, spezifische Kommandos auszuwählen. In diesem Interface sind die verschiedenen Navigationskommandos auf einem Kreis dargestellt. Ein Strich rotiert ständig in der Mitte des Kreises. Der Proband kontrolliert mit nur zwei Denkzielen den Strich in der Weise, dass er das gewünschte Kommando erreicht. Nach einem Eingangstraining von drei Sitzungen waren acht von fünfzehn unbefangenen Personen in der Lage, durch das virtuelle Umfeld zu navigieren, indem sie zwischen rechtshändigen Bewegungen und Ruhestadium unterschieden. Mit Ausnahme eines Probanden verbesserten alle ihre Ergebnisse bei jedem Durchgang, und eine durchschnittliche Fehlerquote von 23.75% wurde erreicht.
©2009 by Walter de Gruyter Berlin New York
Articles in the same Issue
- Research articles
- Modeling of cardiac ischemia in human myocytes and tissue including spatiotemporal electrophysiological variations / Modellierung kardialer Ischämie in menschlichen Myozyten und Gewebe
- A two-class brain computer interface to freely navigate through virtual worlds / Ein Zwei-Klassen-Brain-Computer-Interface zur freien Navigation durch virtuelle Welten
- On the selection of the nozzle geometry and other parameters for cutting corneal flaps with waterjets / Düsengeometrie und andere Parameter beim Wasserstrahlschneiden von Hornhautscheiben
- Simulation of force loaded knee movement in a newly developed in vitro knee simulator / Simulation von belastungsabhängigen Kniebewegungen in einem neuartigen Knie-Simulator für In-vitro-Studien
- Biomechanische Studie zu vier winkelstabilen distalen palmaren Radiusplatten und einer nichtwinkelstabilen Radiusplatte: Steifigkeit und Versagenstests am Kadavermodell / Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model
Articles in the same Issue
- Research articles
- Modeling of cardiac ischemia in human myocytes and tissue including spatiotemporal electrophysiological variations / Modellierung kardialer Ischämie in menschlichen Myozyten und Gewebe
- A two-class brain computer interface to freely navigate through virtual worlds / Ein Zwei-Klassen-Brain-Computer-Interface zur freien Navigation durch virtuelle Welten
- On the selection of the nozzle geometry and other parameters for cutting corneal flaps with waterjets / Düsengeometrie und andere Parameter beim Wasserstrahlschneiden von Hornhautscheiben
- Simulation of force loaded knee movement in a newly developed in vitro knee simulator / Simulation von belastungsabhängigen Kniebewegungen in einem neuartigen Knie-Simulator für In-vitro-Studien
- Biomechanische Studie zu vier winkelstabilen distalen palmaren Radiusplatten und einer nichtwinkelstabilen Radiusplatte: Steifigkeit und Versagenstests am Kadavermodell / Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model