Development of a simple low noise amplifier for recording of sensory mass signals from peripheral nerves / Entwicklung eines einfachen rauscharmen Verstärkers zur Ableitung von sensorischen Summensignalen am peripheren Nerven
-
Thomas Stieglitz
Abstract
In the present work, a simple low noise amplifier system with relatively few components for the recording of peripheral nerve signals via electrodes, such as cuff electrodes, was developed. The amplifier system was developed with the aid of a computer-aided characterization tool, which allowed the characterization of bioelectric signal amplifiers and the identification of system parameters. Three commercially available amplifier systems were investigated with this tool regarding their technical parameters. In addition, peripheral sensory nerve mass signals were analyzed to validate the target specifications for the amplifier to be designed with regard to amplitude and frequency range. An amplifier was designed and developed according to these specifications, characterized in comparison to the commercial amplifiers, and successfully applied in pilot experiments on the sciatic nerve in a rat animal model.
Zusammenfassung
Innerhalb dieser Arbeit wurde ein einfaches Verstärkersystem aus wenigen Komponenten entwickelt, das sich für die Ableitung von Summensignalen peripherer Nerven eignet. Das Verstärkersystem wurde mit Hilfe eines computergestützten Werkzeuges zur Charakterisierung von Verstärkersystemen entwickelt, welches eine Charakterisierung von Verstärkern für bioelektrische Signale und die Identifikation von Systemparametern ermöglicht. Um einen Überblick über relevante Parameter kommerziell erhältlicher Verstärkersysteme zu erhalten, wurden drei kommerziell erhältliche Systeme untersucht. Zusätzlich wurden Summensignale peripherer Nerven analysiert, um die gewonnen Daten im Hinblick auf Amplitude und Frequenzgehalt in den Verstärkerentwurf einfließen zu lassen. Ein Verstärker wurde entsprechend diesen Spezifikationen entworfen, entwickelt, im Vergleich zu den untersuchten kommerziell erhältlichen Systemen verglichen und abschließend erfolgreich im Kleintiermodell am Ischiasnerv der Ratte in Verbindung mit Cuff-Elektroden eingesetzt.
©2009 by Walter de Gruyter Berlin New York
Artikel in diesem Heft
- Research articles
- Development of a simple low noise amplifier for recording of sensory mass signals from peripheral nerves / Entwicklung eines einfachen rauscharmen Verstärkers zur Ableitung von sensorischen Summensignalen am peripheren Nerven
- Computer- and robot-assisted stereotaxy for high-precision small animal brain exploration / Computer- und robotergestützte Stereotaxie für hochpräzise Exploration des Kleintierhirns
- Postoperative aqueous outflow in the human eye after glaucoma filtration surgery: biofluidmechanical considerations
- Intraorale Diagnostik mittels konfokaler Laser-Scanning-Mikroskopie / Intraoral diagnostics using confocal laser scanning microscopy
- Influence of gestational age on the effectiveness of spatial and temporal methods for the reconstruction of the fetal magnetocardiogram
- Flussuntersuchungen an Strömungsphantomen im Vor- und Nachlauf stenoseförmiger Verengungen mittels geschwindigkeitskodierter MRT und numerischer Simulation der Fluiddynamik / Fluid studies on flow behaviour in narrowing vessels with PC-velocimetry and numerical simulations
- Short communication
- Post-processing technique for improved assessment of hard tissues in the submicrometer domain using local synchrotron radiation-based computed tomography / Nachbearbeitungstechnik für eine verbesserte Erfassung harten Gewebes im Submikrometerbereich mittels lokaler synchrotronstrahlungsbasierter Computertomographie
Artikel in diesem Heft
- Research articles
- Development of a simple low noise amplifier for recording of sensory mass signals from peripheral nerves / Entwicklung eines einfachen rauscharmen Verstärkers zur Ableitung von sensorischen Summensignalen am peripheren Nerven
- Computer- and robot-assisted stereotaxy for high-precision small animal brain exploration / Computer- und robotergestützte Stereotaxie für hochpräzise Exploration des Kleintierhirns
- Postoperative aqueous outflow in the human eye after glaucoma filtration surgery: biofluidmechanical considerations
- Intraorale Diagnostik mittels konfokaler Laser-Scanning-Mikroskopie / Intraoral diagnostics using confocal laser scanning microscopy
- Influence of gestational age on the effectiveness of spatial and temporal methods for the reconstruction of the fetal magnetocardiogram
- Flussuntersuchungen an Strömungsphantomen im Vor- und Nachlauf stenoseförmiger Verengungen mittels geschwindigkeitskodierter MRT und numerischer Simulation der Fluiddynamik / Fluid studies on flow behaviour in narrowing vessels with PC-velocimetry and numerical simulations
- Short communication
- Post-processing technique for improved assessment of hard tissues in the submicrometer domain using local synchrotron radiation-based computed tomography / Nachbearbeitungstechnik für eine verbesserte Erfassung harten Gewebes im Submikrometerbereich mittels lokaler synchrotronstrahlungsbasierter Computertomographie