A robust optical respiratory trigger for small rodents in clinical whole-body MR systems / Ein robuster optischer Atemtrigger für Kleinsäuger in klinischen Ganzkörper-MR-Scannern

  • , , , and
Published/Copyright: June 11, 2008
Biomedical Engineering / Biomedizinische Technik
From the journal Volume 53 Issue 3

Abstract

An increasing number of animal experiments are currently conducted on clinical MR systems. Motion artefacts due to breathing can become quite apparent, in particular with abdominal examinations. These artefacts can be reduced by using a triggered acquisition. However, the built-in detectors in human whole-body scanners are usually not sensitive enough to detect the tiny movements of small rodents. Therefore, a sensitive optical motion detector was developed together with a simple, robust analogue circuit. This circuit converts the original optical signal into an electrical one, compensates slow drifts and offsets, and finally generates a transistor-transistor logic trigger signal as input for the clinical whole-body magnetic resonance scanner. The trigger was successfully applied in mouse experiments.

Zusammenfassung

Tierexperimente werden immer häufiger auch an klinischen Ganzkörper-Magnetresonanz (MR)-Systemen durchgeführt. Gerade bei abdominellen Untersuchungen verursacht die Atembewegung der Kleinsäuger jedoch oft Bewegungsartefakte in den MR-Bildern. Diese Bewegungsartefakte können durch Triggerung der MR-Messung auf die Atembewegung deutlich reduziert werden. Allerdings sind die in den Scannern integrierten Atemdetektorsysteme in der Regel zu unempfindlich für Kleinsäuger, wie Mäuse oder Ratten. Daher wurde ein empfindlicher optischer Bewegungssensor zusammen mit einer einfachen, robusten Analogschaltung entwickelt. Diese Schaltung wandelt das optische Signal in ein elektrisches um, kompensiert langsame Drifts und Offsetspannungen und generiert ein Transistor-Transistor-Logic-Signal zur Triggerung des MR-Scanners. Der Trigger wurde erfolgreich an Mäusen getestet.


Corresponding author: Dr. Karl-Heinz Herrmann, AG Medizinische Physik, Institut für interventionelle und diagnostische Radiologie, Universitätsklinikum Jena, Philosophenweg 3, 07743 Jena, Germany Phone: +49-3641-935365 Fax: +49-3641-935081

Received: 2007-8-10
Accepted: 2008-2-25
Published Online: 2008-06-11
Published in Print: 2008-06-01

©2008 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Review
  2. Molekulare Signalwege der aseptischen Endoprothesenlockerung / Molecular pathways in aseptic loosening of orthopaedic endoprosthesis
  3. Research articles
  4. A novel transcutaneous vagus nerve stimulation leads to brainstem and cerebral activations measured by functional MRI / Funktionelle Magnetresonanztomographie zeigt Aktivierungen des Hirnstamms und weiterer zerebraler Strukturen unter transkutaner Vagusnervstimulation
  5. Brustvolumenbestimmung anhand der 3-D-Oberflächengeometrie: Verifizierung der Methode mit Hilfe der Kernspintomographie / Breast volume assessment based on 3D surface geometry: verification of the method using MR imaging
  6. Femoral stiffness and strength critically depend on loading angle: a parametric study in a mouse-inbred strain
  7. Osteosynthese am proximalen Humerus mittels winkelstabiler Platte oder Doppelplatte: eine vergleichende biomechanische Untersuchung / Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study
  8. A robust optical respiratory trigger for small rodents in clinical whole-body MR systems / Ein robuster optischer Atemtrigger für Kleinsäuger in klinischen Ganzkörper-MR-Scannern
  9. Precursors of syncope in linear and non-linear parameters of heart rate variability during pediatric head-up tilt test
  10. Short communication
  11. Effects of poorly perfused peripheries on derived transit time parameters of the lower and upper limbs
  12. Letters to the editor
  13. Comments on “Vigilance monitoring – review and practical aspects”, by Sebastian Canisius and Thomas Penzel; Biomed Tech 2007; 52: 77–82
  14. Response to “Comments on ‘Vigilance monitoring – review and practical aspects’, by Sebastian Canisius and Thomas Penzel”; Biomed Tech 2008; 53: 160–161
Downloaded on 19.4.2026 from https://www.degruyterbrill.com/document/doi/10.1515/BMT.2008.020/html
Scroll to top button