Home Robust filters for intensive care monitoring: beyond the running median / Robuste Filter für intensivmedizinisches Monitoring: mehr als ein gleitender Median
Article
Licensed
Unlicensed Requires Authentication

Robust filters for intensive care monitoring: beyond the running median / Robuste Filter für intensivmedizinisches Monitoring: mehr als ein gleitender Median

  • Karen Schettlinger , Roland Fried and Ursula Gather
Published/Copyright: August 18, 2006
Become an author with De Gruyter Brill
Biomedical Engineering / Biomedizinische Technik
From the journal Volume 51 Issue 2

Abstract

Current alarm systems in intensive care units create a very high rate of false positive alarms because most of them simply compare physiological measurements to fixed thresholds. An improvement can be expected when the actual measurements are replaced by smoothed estimates of the underlying signal. However, classical filtering procedures are not appropriate for signal extraction, as standard assumptions, such as stationarity, do no hold here: the time series measured often show long periods without change, but also upward or downward trends, sudden shifts and numerous large measurement artefacts. Alternative approaches are needed to extract the relevant information from the data, i.e., the underlying signal of the monitored variables and the relevant patterns of change, such as abrupt shifts and trends. This article reviews recent research on filter-based online signal extraction methods designed for application in intensive care.

Zusammenfassung

Die gegenwärtig auf medizinischen Intensivstationen eingesetzten Alarmsysteme führen zu einem hohen Anteil an falsch-positiven Alarmen, da sie größtenteils auf einfachen Schwellwert-Vergleichen basieren. Eine Ersetzung der physiologischen Rohdaten durch eine Schätzung des zugrunde liegenden Signals mittels Glättungsverfahren verspricht diesbezüglich eine Verbesserung. Da jedoch Standard-Annahmen der Zeitreihenanalyse, wie z.B. Stationarität, für intensivmedizinische Daten nicht erfüllt sind, eignen sich übliche Filter in diesem Kontext nicht. Die zu analysierenden Zeitreihen verlaufen zwar häufig über große Zeitabschnitte ohne große Änderungen, weisen aber auch Trends und Sprünge sowie eine große Anzahl an Messartefakten auf. Aus diesem Grund werden alternative Ansätze benötigt, um die wesentlichen Informationen zeitnah aus den Daten zu extrahieren, nämlich die zugrunde liegenden Signalwerte der überwachten Variablen und relevante Muster wie Sprünge und Trendänderungen. Dieser Artikel gibt einen Überblick über neue Filter zur Online-Signalextraktion in der Intensivmedizin.


Corresponding author: Dipl.-Stat. Karen Schettlinger, Fachbereich Statistik, Universität Dortmund, 44221 Dortmund, Germany Phone: +49-231-7554350 Fax: +49-231-7553505

References

1 Bernholt T, Fried R. Computing the update of the repeated median regression line in linear time. Inform Process Lett2003; 88: 111–117.10.1016/S0020-0190(03)00350-8Search in Google Scholar

2 Bernholt T, Fried R, Gather U, Wegener I. Modified repeated median filters. Stat Comput2006; 16: 177–192.10.1007/s11222-006-8449-1Search in Google Scholar

3 Davies PL, Fried R, Gather U. Robust signal extraction for on-line monitoring data. J Stat Plan Inf2004; 122: 65–78.10.1016/j.jspi.2003.06.012Search in Google Scholar

4 Fried R. Robust filtering of time series with trends. J Nonparametr Stat2004; 16: 313–328.10.1080/10485250410001656444Search in Google Scholar

5 Fried R. Robust location estimation under dependence. J Stat Comput Sim 2006; in press.Search in Google Scholar

6 Fried R, Bernholt T, Gather U. Repeated median and hybrid filters. Comput Stat Data Anal2006; 50: 2313–2338.10.1016/j.csda.2004.12.013Search in Google Scholar

7 Fried R, Einbeck J, Gather U. Weighted repeated median smoothing and filtering. Technical report 33. Dortmund: University of Dortmund 2005.Search in Google Scholar

8 Fried R, Gather U. Fast and robust filtering of time series with trends. In: Härdle W, Rönz B, editors. Proceedings in Computational Statistics, COMPSTAT 2002. Heidelberg: Physica 2002: 367–372.10.1007/978-3-642-57489-4_54Search in Google Scholar

9 Fried R, Gather U. Robust trend estimation for AR(1) disturbances. Austrian J Stat2005; 34: 139–151.10.17713/ajs.v34i2.407Search in Google Scholar

10 Gather U, Fried R. Robust estimation of scale for local linear temporal trends. Tatra Mountains Math Publ2003; 26: 87–101.Search in Google Scholar

11 Gather U, Fried R. Methods and algorithms for robust filtering. In: Antoch J, editor. Proceedings in Computational Statistics, COMPSTAT 2004. Heidelberg: Physica 2004: 159–170.10.1007/978-3-7908-2656-2_12Search in Google Scholar

12 Gather U, Schettlinger K, Fried R. Online signal extraction by robust linear regression. Computation Stat2006; 21: 33–51.10.1007/s00180-006-0249-8Search in Google Scholar

13 Grübel R. Length of the shorth. Ann Stat1988; 16: 619–628.10.1214/aos/1176350823Search in Google Scholar

14 Heinonen P, Kalli S, Turjanmaa V, Neuvo Y. Generalized median filters for biological signal processing. In: Proceedings of the 7th European Conference on Circuit Theory and Design 1985: 283–386.Search in Google Scholar

15 Heinonen P, Neuvo Y. FIR-median hybrid filters. IEEE Trans Acoust Speech Signal Process1987; 35: 832–838.10.1109/TASSP.1987.1165198Search in Google Scholar

16 Heinonen P, Neuvo Y. FIR-median hybrid filters with predictive FIR substructures. IEEE Trans Acoust Speech Signal Process1988; 36: 892–899.10.1109/29.1600Search in Google Scholar

17 Himayat N, Kassam SA. Approximate performance analysis of edge preserving filters. IEEE Trans Signal Process1993; 4: 2764–2776.10.1109/78.236501Search in Google Scholar

18 Huber PJ. Robust statistics. New York: Wiley 1981.10.1002/0471725250Search in Google Scholar

19 Imhoff M, Bauer M, Gather U, Fried R. Pattern detection in intensive care monitoring time series with autoregressive models: influence of the model order. Biometrical J2002; 44: 746–761.10.1002/1521-4036(200209)44:6<746::AID-BIMJ746>3.0.CO;2-2Search in Google Scholar

20 Lee Y, Kassam SA. Generalized median filtering and related nonlinear filtering techniques. IEEE Trans Acoust Speech Signal Process1985; 33: 672–683.10.1109/TASSP.1985.1164591Search in Google Scholar

21 Rousseeuw PJ. Least median of squares regression. J Am Stat Assoc1984; 79: 871–880.10.1080/01621459.1984.10477105Search in Google Scholar

22 Rousseeuw PJ. Multivariate estimation with high breakdown point. In: Grossmann W, Pflug G, Vincze I, Wertz W, editors. Mathematical statistics and applications. Vol. B. Dordrecht: Reidel 1985: 283–297.10.1007/978-94-009-5438-0_20Search in Google Scholar

23 Rousseeuw PJ, Croux C. Alternatives to the median absolute deviation. J Am Stat Assoc1993; 88: 1273–1283.10.1080/01621459.1993.10476408Search in Google Scholar

24 Rousseeuw PJ, Hubert M. Regression depth. J Am Stat Assoc1999; 94: 388–402.10.1080/01621459.1999.10474129Search in Google Scholar

25 Rousseeuw PJ, Leroy A. A robust scale estimator based on the shortest half. Stat Neerl1988; 42: 103–116.10.1111/j.1467-9574.1988.tb01224.xSearch in Google Scholar

26 Siegel AF. Robust regression using repeated medians. Biometrika1982; 69: 242–244.10.1093/biomet/69.1.242Search in Google Scholar

27 Tukey JW. Exploratory data analysis. Reading, MA: Addison-Wesley 1977.Search in Google Scholar

Published Online: 2006-08-18
Published in Print: 2006-07-01

©2006 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Biosignal Processing: the pacemaker for innovations in Biomedical Engineering – state, developments, trends
  2. Analysis of complex physiological systems by information flow: a time scale-specific complexity assessment / Analyse komplexer physiologischer Systeme mit Hilfe des Informationsflusses über spezielle Zeitskalen
  3. Robust filters for intensive care monitoring: beyond the running median / Robuste Filter für intensivmedizinisches Monitoring: mehr als ein gleitender Median
  4. Brain-computer interfaces for control of neuroprostheses: from synchronous to asynchronous mode of operation / Brain-Computer Interfaces zur Steuerung von Neuroprothesen: von der synchronen zur asynchronen Funktionsweise
  5. Development of interaction measures based on adaptive non-linear time series analysis of biomedical signals / Entwicklung von Interaktionsmaßen auf der Grundlage adaptiver, nichtlinearer Zeitreihenanalyse von biomedizinischen Signalen
  6. Comparison of three methods for beat-to-beat-interval extraction from continuous blood pressure and electrocardiogram with respect to heart rate variability analysis / Vergleich von drei Methoden der Schlag-zu-Schlag-Intervall-Extraktion aus kontinuierlichen Blutdruckverläufen und Elektrokardiogrammen zur Herzratenvariabilitätsanalyse
  7. Compression entropy contributes to risk stratification in patients with cardiomyopathy / Kompressionsentropie zur verbesserten Risikostratifizierung bei Patienten mit DCM
  8. Identification of patients with coronary artery disease using magnetocardiographic signal analysis / Identifizierung von Patienten mit koronarer Herzkrankheit anhand magnetokardiographischer Signalanalyse
  9. EEG parameters and their combination as indicators of depth of anaesthesia / EEG-Parameter und deren Kombination für das Narkosemonitoring
  10. Oberflächenkonditionierung für eine verbesserte Überlebenswahrscheinlichkeit von Knieprothesen: Komplett- vs. Oberflächenzementiertechnik der Tibiakomponente / Surface pretreatment for prolonged survival of cemented tibial prosthesis components: full- vs. surface-cementation technique
  11. Die Bedeutung der Setzkraft für die Sicherheit einer Konuskopplung von Hüftstiel und keramischem Prothesenkopf / Relevance of the insertion force for the taper lock reliability of a hip stem and a ceramic femoral head
Downloaded on 16.10.2025 from https://www.degruyterbrill.com/document/doi/10.1515/BMT.2006.010/html
Scroll to top button