Abstract

The microstructure of hydroxyapatite (HAP) ceramic coatings deposited by plasma spraying on TiNi shape memory alloy substrates was investigated. With respect to metal/ ceramic interface strength, excellent coatings of HAP on TiNi substrates were prepared. From the point of view of adherence, these coatings possess higher strength than Epoxy 1200 adhesive (≈ 30 MPa). The observed excellent metal/ceramic interface strength is attributed to the formation of chemical bonding according to the reaction Ca10(PO4)6(OH)2 + 2TiO2 → 3Ca3(PO4)2 + CaTi2O5 + H2O and the energy dissipation due to stress-induced martensite formation (SIM) and/or martensite reorientation (RE) during stressing the composite and failure. The applied power parameters of the plasma spraying influence the porosity and fusion between particles of the ceramic coatings.

Abstract

Das Mikrogefüge von Hydroxylapatitschichten (HAP), durch Plasmasprühen auf TiNi-Formgedächtnislegierungen aufgebracht, wurde untersucht. Dabei konnten ausgezeichnete Erfolge hinsichtlich der Festigkeit der Metall/Keramik-Grenzfläche erzielt werden. Die Haftfestigkeit dieser Schichten ist größer als die des Epoxy 1200-Klebers (≈ 30 MPa). Diese ausgezeichnete Grenzflächenfestigkeit läßt sich einerseits auf chemische Bindung entsprechend der Reaktion Ca10(PO4)6(OH)2 + 2TiO2 → 3Ca3(PO4)2 + CaTi2O5 + H2O zürückführen und andererseits auf Bildung von spannungsinduziertem Martensit (SIM) bzw. Martensitumorientierung. Die elektrischen Parameter bei Plasmasprühverfahren beeinflußen die Porosität und den Grad der Teilchenverschmelzung in den keramischen Schichten.


Peter Filip, Karel Mazanec Technical University of Ostrava. Institute of Materials Engineering, CZ-70833 Ostrava-Poruba Czech Republic
Radek Melichárek Moravia a.s., Nádražni 50. CZ-78366 Hlubočky-Mariánské Údolí, Czech Republic
Albert C. Kneissl University of Leoben, Institute of Physical Metallurgy, and Materials Testing, A-8700 Leoben, Austria

Literature

1 Silver, F.H.: Biomaterials, Medical Devices and Tissue Engineering, Chapman and Hall, London (1994).Suche in Google Scholar

2 Poulmaire, D.; Ducos, M.; Setti, Y.; Hypolite, M.P.: in: S. Blumm-Sandmeier, H. Eschnauer, P. Huber, A.R. Nicoll (eds.), 2nd Plasma-Technik Symp., Proceedings Vol. 3, June 1991, Luzern, Swiss, Plasma Technik AG, Wohlen, Swiss (1991) 191 – 199.Suche in Google Scholar

3 Søballe, K.:Acta Orthopaedica Scandinavica, Supplementum No. 255, 64 (1993).Suche in Google Scholar

4 Filip, P.; Kneissl, A.C.; Mazanec, K.: Proc. Int. Metallography Conf., Colmar, France, May 1995, in print.Suche in Google Scholar

5 Rey, C.; in: W. Bonfield, G.W. Hastings, K.E. Tanner (eds.), Bio-ceramics, Butterworth-Heinemann, 4 (1991) 57 – 63.Suche in Google Scholar

6 Musil, J.; Cervená, Z.; Burda, Z.; Kasl, J.; Tosnar, L.; Denk, F.: as Ref. [2] 179 – 186.Suche in Google Scholar

7 Gutekunst, G.; Mayer, J.; Rühle, M.: Scripta metall. mater. 31 (1994) 1097 – 1102.10.1016/0956-716X(94)90533-9Suche in Google Scholar

8 Filip, P.:„Physical Metallurgy Parameters of Shape Memory Phenomena in TiNi Alloys and Their Practical Use“, Ph. D. Thesis,TU of Ostrava (1988) (in Czech).Suche in Google Scholar