An electrochemical technique to prepare 55Fe source for the calibration of the X-ray detectors
-
Manoj Kumar
Abstract
This paper describes an electrochemical method for the preparation of 55Fe sources, utilized in the calibration of low energy X-ray detectors. In this process, electrodeposition of 55Fe containing 185 MBq (∼5 mCi) of activity on a small circular cross sectional flat surface area (∼0.07 cm2) within a cylindrical Cu metal rod was carried out at a current density of 20 mA/cm2 at 18 ºC for 4 h using sulphate bath maintained at pH ∼ 2. The electrolytic cell, the experimental set up used and the process of 55Fe deposition were described. The effect of various experimental parameters influencing the electrodeposition of 55Fe were identified and optimized. The texture and morphology of the electrodeposited samples were examined by X-ray diffraction (XRD), SEM and EDS techniques. The quantity of deposited 55Fe activity was assayed in a calibrated ion chamber. Quality control tests were carried out to ensure nonleachability, uniform distribution of activity and stability of the sources.
© by Oldenbourg Wissenschaftsverlag, München, Germany
Articles in the same Issue
- Thermodynamics of Np(IV) complexes with gluconic acid under alkaline conditions: sorption studies
- Interaction of uranium(VI) with bioligands present in human biological fluids: the case study of urea and uric acid
- Approach to on-line monitoring of PUREX process using chemometric processing of the optical spectral data
- Development and demonstration of a new SANEX Partitioning Process for selective actinide(III)/lanthanide(III) separation using a mixture of CyMe4BTBP and TODGA
- Solid phase extraction of trivalent actinides and lanthanides using a novel CMPO-RTIL based chromatographic resin
- Stability studies of N,N,N´,N´-tetra-(2-ethylhexyl) dithiodiglycolamide (DTDGA)
- The effect of fluoride and silicate ions on the coprecipitation of gadolinium with calcium in phosphoric and sulpho-phosphoric media
- An electrochemical technique to prepare 55Fe source for the calibration of the X-ray detectors
- A novel and facile approach for the preparation of 133Ba source core, encapsulation and quality evaluation
Articles in the same Issue
- Thermodynamics of Np(IV) complexes with gluconic acid under alkaline conditions: sorption studies
- Interaction of uranium(VI) with bioligands present in human biological fluids: the case study of urea and uric acid
- Approach to on-line monitoring of PUREX process using chemometric processing of the optical spectral data
- Development and demonstration of a new SANEX Partitioning Process for selective actinide(III)/lanthanide(III) separation using a mixture of CyMe4BTBP and TODGA
- Solid phase extraction of trivalent actinides and lanthanides using a novel CMPO-RTIL based chromatographic resin
- Stability studies of N,N,N´,N´-tetra-(2-ethylhexyl) dithiodiglycolamide (DTDGA)
- The effect of fluoride and silicate ions on the coprecipitation of gadolinium with calcium in phosphoric and sulpho-phosphoric media
- An electrochemical technique to prepare 55Fe source for the calibration of the X-ray detectors
- A novel and facile approach for the preparation of 133Ba source core, encapsulation and quality evaluation