Abstract
A prototype flexible thermoelectric generator fabricated with bulk materials is presented. Mineral-fiber band and copper tape are used as flexible substrate and electric connectors, respectively, to coil up the constructed thermoelectric device under investigation. The applied active thermoelectric materials are
Introduction
Studies on thermoelectric systems focus on thermoelectrically active materials and on entire thermoelectric devices that consist of different materials. Hence, thermoelectric investigations are highly interdisciplinary and involve fields ranging from solid state chemistry, for the development of new materials, to fabrication engineering, including geometric and electronic research. The crucial quantities in determining the thermoelectric properties of a material are the isothermal (
The leg-area related flux densities for the entropy
In addition to trying to apply certain materials to certain temperature conditions, the geometric properties of a complete thermoelectric generator (TEG) must be considered. Many studies have considered
Hence, a TEG is a device that transfers energy from an entropy current to an electric current; see Fuchs (2010, 2014), Feldhoff (2015).These properties make a thermoelectric generator that is useful for recovering waste heat in different processes.
Most of the current studies on flexible or even coilable thermoelectric systems are based on thin-film or at least thick-film technology. Thin-film fabrication often uses
The present approach allows the inclusion of different material classes, as oxides and metals, without considering the contact of the grains forming the entire bulk phase. Furthermore, the costs of the
Experimental
Material Synthesies and Preparation
The p-type thermoelectric oxide
The Cu-Ni alloy was in the form of a commercially available wire with a diameter of 1 mm. To connect the thermoelectric materials, adhesive Cu-tape was attached on a mineral-fiber band (HORST GmbH; order-nr.: 10 03 02). The thermoelectric materials were mounted to the Cu connectors and attached by a commonly used solder, to obtain the electric series connection, that is essential for the device. Silver paste was used to connect the thermoelectric materials with the Cu connectors through the solder. Silver paste is used to avoid other preparation technologies such as physical vapor deposition (PVD) when coating the ceramic surface with a metallic layer. It is not possible to use the silver paste without soldering, because this leads to the delamination of the silver layer from the Cu surface during heating due to the thermomechanical stresses inside the assembled layer structure. The manufacturer’s physical data for applied commercial materials are listed in Table 1. The parameters for the Cu tape were taken from the data sheet prepared by Deutsches Kupfer-Institut e.V. (DKI), see Franke and Juhl (2000). The entropy conductivity at open-circuit conditions
Physical manufacturer’s data of applied commercial materials with thermoelectric parameters for 293 K.
| material |
|
|
|
|
|
| mineral fiber |
|
1.0 | 3.4 |
n.a. | 890 ( |
| Cu tape | 1.7 |
394 | 1.3 | n.a. | 1,356 ( |
| Cu-Ni alloy | 4.9 |
23 | 7.8 |
–40 | 1,553 ( |
| Sn-Pb solder | 1.4 |
50 | 1.7 |
n.a. | 456 ( |
Thermoelectric Measurements of Single Materials
To characterize the thermoelectric properties of the materials, the temperature-dependent isothermal specific electric resistivity and the Seebeck coefficient, as estimated from the thermovoltage, were measured. Using these data the power factor

Schematic illustration of the measurement setup for determining the thermoelectric characteristics of single materials. (a) setup for determining the specific isothermal electric resistance, (b) setup for determining the Seebeck coefficient.
Thermoelectric Measurements of Prototype TEG
The fabricated prototype was placed on a heater to estimate its thermoelectric characteristics. The heat sink was established naturally, using the temperature drop, that was generated by radiation losses without any additional setup for passive or active cooling. Hence, the temperature of the cold junction of the device increased with the increasing temperature of the hot side (heater side). The used heat-source was a STUART CB160 hot-plate. The prototype TEG was placed on the heater in a bent form as shown in Figure 3(c). A schematic illustration of the measurement setup is shown in Figure 2. The temperature was measured using thermocouples. The thermovoltage
Microstructure Analysis
The materials were analyzed using field-emission scanning electron microscopy (FE-SEM) using a JEOL JSM-6700F, equipped with an Oxford Instruments INCA 300 energy-dispersive X-ray spectrometer (EDXS) for elemental analysis. The phase composition of
Fabrication of the Flexible Thermoelectric Generator
Figure 3 shows the fabricated device as a flat stripe and in perspective view to show the provided flexibility. The basic material of the developed generator is a mineral-fiber band that provides a flexible substrate for the TEG stripe. The band is 14.5 mm wide and 150

Microphotography of the prototype flexible TEG; (a) side view on plan side, (b) perspective view on bend device, (c) top view on bend device.
To examine the inside of the fabricated device, a basic unit was cut out and embedded in epoxy resin to fix the thin and flexible part of the device. A cross-section was then obtained by cutting and polishing the assembled materials. A photograph of the cross-section of the prepared basic unit is shown in Figure 4. With the exception the silver paste all components of the prepared basic unit of the prototype flexible TEG can be seen. Related to the prepared cut, the Cu-Ni alloy wire is completely surrounded by the used solder (right side of the basic unit). The ceramic

(a) Microphotograph of cut and polished cross-section of the prepared basic unit surrounded by epoxy resin (mineral-fiber band is not visible); (b) pseudocolor micrograph of
Figure 5 shows the area-related elemental distributions of the cut and polished cross-section of the prepared basic unic. The detailed results for elemental distribution of each element are presented.

EDXS elemental maps of cut and polished cross-section of the prepared basic unit: (a) Secondary electron micrograph of the
The interface of the ceramic
Results and Discussion
Microstructure of Materials and Compositions
The crystal structures of the calcined powder product and the sintered p-type

XRD analysis of semi-conducting

EDX spectra of synthesized and prepared materials. (a) sintered
Figure 7 shows the elemental compositions of the thermoelectric
Thermoelectric Investigations
The experimental errors for measurements of the Seebeck coefficients and for the isothermal specific electric resistivities were estimated by considering the errors for sample’s geometry measurements, fluctuations of electrical quantities and fluctuations in the temperature profile for the measurement of each material. Based on these considerations, we developed a reliability range for each measurement. Figure 9 shows the obtained Seebeck coefficients of the

Measured Seebeck coefficients of applied thermoelectric materials as a function of temperature with estimated error ranges. (a)
The Seebeck coefficients of analyzed materials depend only weakly on temperature. The absolute value of the semiconducting oxide Seebeck coefficient is nearly three times higher than that of the used metallic thermoelectric material. The Seebeck coefficients decreased sharply at approximately room temperature (300 K) due to the vanishing temperature difference along the samples that (not shown). We therefor decided to display the values starting at 330 K and to show the values in the range for with we have reliable measurement data. The Seebeck coefficient of the ceramic material is almost three times higher than the value for the Cu-Ni alloy. The Seebeck coefficient of the Cu-Ni alloy reaches values in the range between –40 and –60
Figure 10 shows the results for isothermal specific electric resistivity

Measured isothermal specific electric resistivities of applied thermoelectric materials as function of temperature with estimated error ranges. (a)
The power factors
To determine the thermoelectric parameters of the flexible prototype TEG, four temperature differences

Thermoelectric properties of the prototype flexible TEG (four basic units, see Figure 3 for length of the device). (a) Voltage over electric current for four different temperature conditions. (b) Power-current characteristics for four different temperature conditions.
Determined thermoelectric parameters of the prototype flexible TEG for different temperature conditions.
|
|
|
|
|
|
|
|
| 420 | 31 | 404 | 851.61 | 82.00 | 16.52 | 19.40 |
| 361 | 22 | 350 | 909.91 | 14.56 | 7.29 | 8.01 |
| 336 | 16 | 328 | 885.94 | 4.65 | 4.06 | 4.58 |
| 307 | 7 | 304 | 715.90 | 0.24 | 0.88 | 1.23 |
The values of the open circuit voltage
Calculated and measured temperature distributions inside the device.
|
|
|
|
|
|
|
| 420 | 31 | 19 | 222.25 | 4.13 | 61.29 |
| 361 | 22 | 9 | 211.06 | 1.82 | 40.91 |
| 336 | 16 | 6 | 182.13 | 1.02 | 37.50 |
Large parasitic heat losses are present along the device’s hot and cold sides and are likely caused by the mineral-fiber substrate. The contact area between the copper-tape and the mineral-fiber band appears to be too large. The mineral-fiber band has to be more slim such that the amount of integrated copper can be reduced to minimize this contact areas. The thermal short-circuited situation can also be caused by the Cu-Ni alloy, which exhibits a larger thermal conductivity compared with the fiber substrate (see Table 1). The alloy must be the main origin of the parasitic heat losses via thermal short circuiting. Figure 13 illustrates the temperature distributions across the hot and cold sides of the device relative to the hot side temperature.

Temperature distributions inside the TEG with displayed thermal losses for hot side
Conclusions
The prototype TEG displays flexibility that is only limited by the applied pieces of ductile copper-tape as electric connectors. The limiting factor for the heating of the device is the solder, which melts between 423 and 473 K. Because of the less heat proofed Sn-Pb solder the prototype can not be applied to temperatures above the decomposition temperature of BiTe. Related to the other materials in the device a reasonable temperature range for application should be up to 890 K (degeneration temperature of the mineral-fiber band). The solder also limits the current because of a very high boundary resistivity at the connecting regions of metallic solder and semiconducting p-type oxide. The geometrical arrangement of the applied materials provides variation of thermoelectric materials while maintaining the mechanical flexibility of the TEG. Metals and alloys as well as ceramics can be integrated in the fabrication process. The joining of dissimilar materials is the major concern. It is therefore important to investigate alternatives to soldering for attaching non-metallic materials to metallic connectors. It is also important to investigate the use of a solder with a higher melting point, such as a Sn-Sb solder, to improve the thermal stability of the entire device. To join ceramic materials to metallic connectors, alternative solutions must be applied to avoid preparation techniques such as physical vapor deposition (PVD). Epoxy resin including metal particles for electric conduction should be tested.
The observed parasitic heat losses are likely caused by the large area of the copper-tape that can transport the heat to the mineral-fiber substrate. The substrate material should be thinner in order to decrease the thermal conduction. To decrease the thermal losses, the width of the substrate material must be smaller to minimize the gap between the hot side of the generator and the hot side of the thermoelectric junctions related to the thermoelectric legs.
Here a symmetric approach to fabrication was used. The legs were centered between the hot and the cold sides of the entire device. This architecture leads to disadvantages for temperature distributions during working conditions. Instead, an asymmetric architecture, in which the legs are placed as near as possible to the hot side using a smaller Cu connector while the Cu connector of the cold side should exhibit a larger area to act as passive cooling system. It is expected that constructing the flexible TEG stripe in such an asymmetric fashion would reduce the parasitic heat losses from the heat source to the hot junction of the thermoelectric materials. For the short piece of the presented prototype it is indeed nearly impossible to integrate an effective heat exchanger. For an upscaled and coiled up version of the prototype it is expected, that the mechanical stability suffice to place a cooler onto the device. Another imaginable possiblity to integrate heat exchanger are miniaturized heat-pipes that are clamped to the electric connectors of each basic unit. For application a thermoelectric energy harvesting device a heat exchanger is considered to be essential.
References
Cao, Z., E. Koukharenko, R. Torah, J. Tudor, and S. Beeby. 2014. “Flexible Screen Printed Thick Film Thermoelectric Generator with Reduced Material Resistivity.” PowerMEMS 557 (012016):1–5. Conference Series.10.1088/1742-6596/557/1/012016Search in Google Scholar
Feldhoff, A. 2015. “Thermoelectric Material Tensor Derived From the Onsager – De Groot – Callen Model.” Energy Harvesting and Systems 2 (1):5–13.10.1515/ehs-2014-0040Search in Google Scholar
Feldhoff, A., M. Arnold, J. Martynczuk, T. Gesing, and H. Wang. 2008. “The Sol-Gel Synthesis of Perovskites by EDTA/Citrite Complexing Method Involves Nanoscale Solid State Reactions.” Solid State Sciences 10:689–701.10.1016/j.solidstatesciences.2007.11.030Search in Google Scholar
Feldhoff, A., and B. Geppert. 2014. “A High-Temperature Thermoelectric Generator based on Oxides.” Energy Harvesting and Systems 1 (1–2):69–78.10.1515/ehs-2014-0003Search in Google Scholar
Francioso, L., C. D. Pascali, I. Farella, C. Martucci, C. Creti, P. Siciliano, and A. Perrone. 2011. “Flexible Thermoelectric Generator for Ambient Assisted Living Wearable Biometric Sensors.” Journal of Power Sources 196:3239–43.10.1016/j.jpowsour.2010.11.081Search in Google Scholar
Franke, H., and K. Juhl. 2000. Kupfer in Der Elektrotechnik-Kabel Und Leitungen. Duesseldorf, DE: Breuerdruck. Internet Version 2000.Search in Google Scholar
Fuchs, H. 2010. The Dynamics of Heat – a Unified Aproach to Thermodynamics and Heat Transfer, 2nd edn. New York: Springer. Graduate Texts in Physics.10.1007/978-1-4419-7604-8Search in Google Scholar
Fuchs, H. 2014. “A Direct Entropic Approach to Uniform and Spatially Continuous Dynamical Models of Thermoelectric Devices.” Energy Harvesting and Systems 1 (3–4):253–65.10.1515/ehs-2014-0011Search in Google Scholar
Geppert, B., D. Groeneveld, V. Loboda, A. Korotkov, and A. Feldhoff. 2015. “Finite-Element Simulations of a Thermoelectric Generator and Their Experimental Validation.” Energy Harvesting and Systems 2 (1):95–104.10.1515/ehs-2015-0001Search in Google Scholar
Glatz, W., S. Munwyler, and C. Hierold. 2006. “Optimisation and Fabrication of Thick Flexible Polymer Based Micro Thermoelectric Generator.” Sensors and Actuators, A 132:337–45.10.1016/j.sna.2006.04.024Search in Google Scholar
Indris, S. 2001. Perkolation Von Grenzflächen in Nanokristallinen Keramischen Kompositen – Li-Ionenleitfähigkeit Und7Li-NMR-Relaxation. Göttingen, DE: Cuvillier Verlag. Dissertation.Search in Google Scholar
Kuznetsov, V. L., L. A. Kuznetsova, A. E. Kaliazin, and D. M. Rowe. 2002. “High Performance Functionally Graded and Segmented Bi2 Te3-based Materials for Thermoelectric Power Generation.” Journal of Materials Science 37:2893–7.10.1023/A:1016092224833Search in Google Scholar
LeBlanc, S., S. K. Yee, M. L. Scullin, C. Dames, and K. E. Goodson. 2014. “Material and Manufacturing Cost Considerations for Thermoelectrics.” Renewable and Sustainable Energy Reviews 32:313–27.10.1016/j.rser.2013.12.030Search in Google Scholar
Lide, D. 2008. CRC Handbook of Chemistry and Physics, 89th edn. Boca Raton, FL: CRC Press. Internet Version 2009.Search in Google Scholar
Lowhorn, N. D., W. Wong-Ng, W. Zhang, Z. Q. Lu, M. Otani, E. Thomas, M. G. T. N. Tran, N. Dilly, S. Ghamaty, N. Elsner, et al. 2009. “Round-Robin Measurements of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material.” Applied Physics A 94:231–4.10.1007/s00339-008-4876-5Search in Google Scholar
Lu, Z. Q. J., N. D. Lowhorn, W. Wong-Ng, W. Zhang, Z. Q. Lu, M. Otani, E. Thomas, M. G. T. N. Tran, N. Dilly, S. Ghamaty, et al. 2009. “Statistical Analysis of a Round-Robin Measurement Survey of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material.” Journal of Research of the National Institute of Standards and Technology 114:37–55.10.6028/jres.114.004Search in Google Scholar PubMed PubMed Central
Miyzaki, Y. 2004. “Crystal Structure and Thermoelectric Properties of the Misfit-Layered Cobalt Oxides.” Solid State Ionics 117:463–7.10.1016/j.ssi.2004.01.046Search in Google Scholar
Poudel, B., Q. Hao, Y. Ma, Y. Lan, A. Minnich, B. Yu, X. Yan, D. Wang, A. Muto, D. Vashaee, et al. 2008. “High-Thermoelectric Performance of Nanostructured Bismuth Antimony Telluride Bulk Alloys.” Science 320:634–8.10.1126/science.1156446Search in Google Scholar PubMed
Rhee, S. 1975. “Porosity-Thermal Conductivity Correlation for Ceramic Materials.” Materials Science and Engineering 20:89–93.10.1016/0025-5416(75)90134-2Search in Google Scholar
Stepien, L., A. Roch, S. Schlaier, I. Dani, A. Kiriy, F. Simon, M. v. Lukowicz, and C. Leyens. 2015. “Investigation of the Thermoelectric Power Factor of KOH Treated PEDOT:PSS Dispersions for Printing Applications.” Energy Harvesting and Systems 2:1–11.10.1515/ehs-2014-0060Search in Google Scholar
Suemori, K., S. Hoshino, and T. Kamata. 2013. “Flexible and Lightweigt Thermoelectric Generators Composed of Carbon Nanotube-Polystyrene Composites Printed on Film Substrate.” Applied Physics Letter 103 (153902):1–4.10.1063/1.4824648Search in Google Scholar
Yoo, B. Y., C.-K. Huang, J. R. Lim, J. Herman, M. A. Rayn, J.-P. Fleurial, and N. V. Myung. 2005. “Electrochemically Deposited Thermoelectric n-Type 2 Te3 Thin Films.” Electrochimica Acta 50:4371–7.10.1016/j.electacta.2005.02.016Search in Google Scholar
©2016 by De Gruyter
Articles in the same Issue
- Frontmatter
- Articles
- Integrated Piezoelectric Energy Harvesting and Organic Storage System
- Design Considerations for Optimal Absorption of Energy from a Vibration Source by an Array of Harvesters
- Efficient Nonlinear Energy Harvesting with Wrinkled Piezoelectric Membranes
- Micro Wind Turbine for Powering Wireless Sensor Nodes
- Autonomous Flyback Converter for Energy Harvesting from Microbial Fuel Cells
- An Approach to a Flexible Thermoelectric Generator Fabricated using Bulk Materials
- Magnetoelectric Alternator
- Giant Magnetoelectric Effect in PZT Thin Film Deposited on Nickel
- Triboelectric Power Generation from Paper Vibration Induced by Sonic Waves
Articles in the same Issue
- Frontmatter
- Articles
- Integrated Piezoelectric Energy Harvesting and Organic Storage System
- Design Considerations for Optimal Absorption of Energy from a Vibration Source by an Array of Harvesters
- Efficient Nonlinear Energy Harvesting with Wrinkled Piezoelectric Membranes
- Micro Wind Turbine for Powering Wireless Sensor Nodes
- Autonomous Flyback Converter for Energy Harvesting from Microbial Fuel Cells
- An Approach to a Flexible Thermoelectric Generator Fabricated using Bulk Materials
- Magnetoelectric Alternator
- Giant Magnetoelectric Effect in PZT Thin Film Deposited on Nickel
- Triboelectric Power Generation from Paper Vibration Induced by Sonic Waves
![Figure 2:
Schematic side-view illustration of the measurement setup for determining the thermoelectric characteristics of the flexible TEG. Schematics for a device with parallel entropy current JS${J_S}$ (see eq. [2]) and electric ring current Jq${J_q}$ (see eq. [3]) are displayed.](/document/doi/10.1515/ehs-2015-0015/asset/graphic/j_ehs-2015-0015_fig_008.jpg)