To the Editor,
Laboratory tests for evaluation of haemostasis-related measurands reflecting coagulation and fibrinolytic activity are used in the diagnostic work-up of bleeding and thrombotic conditions and for monitoring treatment of these disorders. Accurate and precise quantification is necessary for correct diagnosis and subsequent treatment of patients, and robust estimates of biological variation (BV) are important to be able to establish analytical performance specifications, reference change values (RCVs) and personalized reference intervals. Previously, we performed a systematic review and meta-analysis for BV data for haemostasis-related measurands, where we included publications with study periods from more than 1 week up to 3 years [1]. However, coagulation tests are often performed more frequently and within a shorter time frame, especially in critically ill patients. The focus of this study was therefore to perform a systematic review focusing on short-term BV studies defined as study duration up to 7 days and to assess if short-term BV estimates differed from previously published long-term estimates [1].
A literature search performed in PubMed as previously described [1], now with cut-date June 2024, identified six publications where the study periods were up to 7 days in healthy individuals. Out of these publications, one included results from three different study cohorts [2] and another from two different sampling intervals [3], making up nine different sets of results altogether to be assessed. Detailed information about the study subjects, sampling protocol, pre-analytical handling and analytical methods were recorded and the studies were appraised by the Biological Variation Data Critical Appraisal Checklist (BIVAC) [4]. This checklist includes 14 quality items (QI), which were scored with an A to D (A: fully compliant and D: not fit for purpose). The QI with the lowest scoring determines the overall grading of the study. Three independent assessors amongst the authors reviewed and scored the papers. Differences were discussed and a joint score was achieved. If two or more publications reported data for the same measurand, a meta-analysis was performed. BV data for thrombin time and factor V were excluded from one study because in this study, the within-subject BV estimate (CVI) was stated to be “0” for these measurands [5]. Publications presenting no overall BV estimate, but multiple BV estimates (i.e. for men and women with and without use of oral contraceptives (OCs) [2] or for multiple time frames [3]) were not included in the meta-analysis, but shown as single results (Table 1).
Short-term within-subject (CVI) and between-subject (CVG) estimates with 95 % confidence intervals (CIs) of coagulation and fibrinolytic measurands. For measurands in bold and underlined, meta-analysis results are shown.
Measurands | Meta-analysis | References | Study duration | Sampling | Short-term estimates (study period≤7 days) | Long-term estimates (literature data [1]) | ||
---|---|---|---|---|---|---|---|---|
(number of included studies) | (number of days) | (number of samples per subject) | CVI, CI % | CVG, CI % | CVI, CI % | CVG, CI % | ||
APTT, seconds | 2 | [5], 6] | 3.5 (3.4–3.5) | 2.8 (1.7–6.8) | 7.2 (4.9–8.9) | |||
[5] | 1 | 4 | 3.4 (1.3–4.3) | |||||
[6] | 5 | 9 | 3.5 (3.1–3.9) | 10.4 (8.3–13.9) | ||||
APTT, ratio | [6] | 5 | 9 | 3.4 (2.9–3.8) | 10.4 (8.3–13.9) | |||
Antithrombin act | 2 | [5], 7] | 4.9 (4.6–5.2) | 3.4 (1.1–7.0) | 7.8 (2.6–25.2) | |||
[5] | 1 | 4 | 5.2 (4.5–5.9) | |||||
[7] | 5 | 9 | 4.6 (3.9–5.2) | 6.4 (4.9–9.1) | ||||
dRVVT (screen, ratio) | [7] | 5 | 9 | 7.1 (6.3–8.0) | 10.0 (7.6–14.1) | |||
dRVVT (screen, seconds) | [7] | 5 | 9 | 7.1 (6.3–8.0) | 10.0 (7.6–14.1) | |||
dRVVT (screen ratio/confirm ratio) | [7] | 5 | 9 | 4.6 (4.0–5.2) | 6.8 (5.2–9.6) | |||
Factor II | [6] | 5 | 9 | 6.7 (5.9–7.5) | 8.9 (7.0–12.1) | 5.8 (5.7–5.9) | 9.7 (7.0–15.4) | |
Factor Va | [6] | 5 | 9 | 6.7 (6.0–7.4) | 16.8 (13.3–22.5) | 5.3 (3.6–6.6) | 18.7 (14.1–27.5) | |
Factor VII | [6] | 5 | 9 | 7.7 (7.0–8.5) | 12.8 (10.1–17.2) | 8.2 (6.9–14.2) | 17.8 (16.7–19.4) | |
Factor VIII | [6] | 5 | 9 | 11.4 (10.3–12.6) | 24.0 (19.0–32.2) | 8.7 (4.9–16.0) | 22.5 (15.5–31.4) | |
Factor IX | [6] | 5 | 9 | 6.0 (4.7–6.9) | 10.7 (8.4–14.4) | 6.9 (5.8–9.1) | 16.3 (15.7–18.2) | |
Factor X | 2 | [5], 6] | 5.1 (4.8–5.3) | 5.9 (4.6–8.5) | 11.4 (8.2–18.2) | |||
[5] | 1 | 4 | 4.8 (4.1–5.5) | |||||
[6] | 5 | 9 | 5.3 (4.8–5.8) | 12.2 (9.7–16.5) | ||||
Factor XI | [6] | 5 | 9 | 5.2 (4.0–5.9) | 11.0 (8.7–14.8) | 5.1 (4.2–6.3) | 11.5 (8.5–17.5) | |
Factor XII | [6] | 5 | 9 | 5.2 (4.7–5.8) | 23.7 (18.9–31.8) | 4.0 (3.0–5.1) | 23.3 (17.6–34.5) | |
Fibrinogen (Clauss) b | 2 | [5], 6] | 4.8 (3.5–5.3) | 10.2 (9.3–11.9) | 17.1 (8.5–17.3) | |||
[5] | 1 | 4 | 3.5 (1.9–4.3) | |||||
[6] | 5 | 9 | 5.3 (4.8–5.8) | 16.9 (13.4–22.6) | ||||
[3] | 1 | 5 | 10.7 (8.5–12.5) | |||||
[3] | 5 | 5 | 14.2 (11.9–16.5) | |||||
[2] – non-OC | 3 | 2 | 3.3 (2.0–4.6) | 17.8 (15.2–21.3) | ||||
[2] – OC | 3 | 2 | 4.9 (3.6–6.5) | 18.9 (15.8–23.4) | ||||
[2] – men | 5 | 3 | 6.3 (5.5–7.2) | 16.9 (14.7–19.8) | ||||
FDP | [6] | 5 | 9 | 10.0 (8.7–11.1) | 13.9 (10.9–18.8) | |||
Plasmin inhibitor | [5] | 1 | 4 | 6.6 (5.9–7.4) | 5.8 (4.8–5.8) | 7.1 (5.2–10.8) | ||
Plasminogen | [5] | 1 | 4 | 3.8 (3.1–4.4) | 5.7 (4.2–7.7) | 10.5 (7.8–15.8) | ||
PC-Act | [7] | 5 | 9 | 5.6 (4.8–6.3) | 14.3 (11.1–20.0) | 5.5 (5.3–7.9) | 16.9 (9.1–55.2) | |
PS-Act | [7] | 5 | 9 | 7.5 (6.6–8.4) | 16.8 (13.0–23.5) | 7.3 (7.1–8.1) | 20.3 (18.8–23.8) | |
Prothrombin time, sec | [6] | 5 | 9 | 2.5 (2.3–2.8) | 4.6 (3.6–6.2) | 2.6 (2.4–5.8) | 5.1 (2.8–5.7) | |
Prothrombin time, % | [6] | 5 | 9 | 4.6 (4.2–5.1) | 8.1 (6.4–10.9) | |||
Prothrombin time, INR | [6] | 5 | 9 | 2.4 (2.2–2.7) | 4.5 (3.5–6.0) | 2.5 (2.3–3.0) | 4.6 (2.9–6.8) | |
Thrombin timea | [6] | 5 | 9 | 2.1 (1.8–2.3) | 3.9 (3.1–5.2) | |||
t-PA Actb | [2] – non-OC | 3 | 2 | 31.3 (26.9–37.4) | 42.1 (33.9–52.3) | 32.0 (27.6–37.4) | ||
[2] – OC | 3 | 2 | 26.1 (21.9–32.2) | 23.6 (15.6–32.1) | ||||
[2] – men | 5 | 3 | 37.7 (34.3–41.8) | 48.3 (41.0–57.5) | ||||
t-PA Agb | [2] – non-OC | 3 | 2 | 13.0 (10.5–16.1) | 35.4 (30.0–42.7) | 13.3 (11.0–30.9) | 38.1 (23.9–191.1) | |
[2] – OC | 3 | 2 | 15.7 (12.7–19.9) | 40.0 (33.1–49.8) | ||||
[2] – men | 5 | 3 | 14.1 (12.5–16.0) | 29.8 (25.8–35.0) | ||||
PAI-1 Agb | [2] – non-OC | 3 | 2 | 40.0 (34.3–47.8) | 60.9 (49.9–75.0) | 48.6 (35.6–55.0) | 59.8 (26.0–90.0) | |
[2] – OC | 3 | 2 | 51.8 (43.6–63.6) | 63.5 (48.4–82.4) | ||||
[2] – men | 5 | 3 | 37.9 (34.4–42.1) | 70.0 (60.6–82.2) | ||||
VWF Ag | 2 | [7], 8] | 5.7 (5.0–5.8) | 23.2 (18.0–31.7) | 12.7 (11.1–19.4) | 29.9 (22.6–31.6) | ||
[7] | 5 | 9 | 5.8 (5.2–6.6) | 31.7 (24.7–44.2) | ||||
[8] | 7 | 3 | 5 (0–8.5) | 18 (13.7–25.5) |
-
aOne study was excluded because CVI = 0 [5]. bAbbreviation included in column with references including separate studies for: women without or with oral contraceptive (respectively; non-OC and OC) and men [2]. APTT, activated partial thromboplastin time; Act, activity; Ag, antigen; CI, confidence interval; dRVVT, dilute Russell’s viper venom time; FDP, fibrin degradation products; INR, international normalized ratio; PC, protein C; PS, protein S; t-PA, tissue plasminogen activator; PAI-1, plasminogen activator inhibitor 1; VWF, von Willebrand factor.
In the six publications included in this review, BV data were reported for 28 different measurands. One publication reported BV data for 1 day, 5 days and 6 weeks (the data for 1 and 5 days are included in this study) [3] and another publication reported BV data separately for men and for women with and without use of hormonal OC [2]. The highest number of BV estimates were identified for fibrinogen (Clauss), as was also previously observed [1]. All six publications were awarded a BIVAC grade C, due to the lack of outlier analysis (QI8), variance homogeneity testing (QI10), and not reporting the number of results excluded following analysis of outliers and variance homogeneity (QI13). A probable cause for these omissions was the low number of samples per individual (2–9 samples) in these studies. In all studies, samplings were performed during standard working hours. Thus, especially for studies where all the samples were drawn in the same day, this data represents daytime variation, which is relevant for the majority of requested tests in standard laboratories.
No short-term BV studies were identified for the following haemostasis-related measurands; reptilase time, factor XIII and activated clotting time. Short-term BV data were identified for three measurands (dilute russel viper venom time [7], fibrin degradation products [6] and thrombin time [6]) for which there are no long-term BV data available (Table 1) and thus at time of study were not included in the EFLM BV Database.
For most of the measurands where short-term data were identified, meta-analysis could not be performed as only single studies were available. Meta-analyses were performed for five measurands (activated partial thromboplastin time, antithrombin activity, coagulation factor X, fibrinogen (Clauss) and von Willebrand factor (VWF) antigen), each based on two studies (Table 1). In general, the short-term BV estimates were comparable to long-term estimates as previously published [1], for most measurands. Exceptions were seen for fibrinogen (Clauss) and VWF antigen where the long-term CVI estimate was significantly higher than the short-term CVI (p<0.001, Mann–Whitney U-test). Both these measurands are acute-phase reactants. In the long-term studies, it was reported that only healthy individuals were included [9], 10], however, it is possible that mild or subclinical acute phase episodes may have gone undetected. In light of these differences, it may be argued that more stringent APS are needed for settings where monitoring is more frequent e.g. before and after substitution therapy, in stable patients. However, most laboratories will typically serve both types of populations and in this case, the more stringent APS should, preferably, be fulfilled. One study on fibrinogen (Clauss) reported CVI estimates for one single day (CVI=10.7 %, range: 8.5–12.5 %), 5 days (CVI=14.2 %, range: 11.9–16.5 %) and 6-weeks (CVI=17.8 %, range: 16.0–19.8 %) [3]. Although a significantly higher CVI was found for the 6-weeks study period compared to the 1 and 5 days study periods, the short-term BV estimates (1 day and 5 days) were similar to the long-term CVI for fibrinogen (Clauss) identified in our previous meta-analysis [1], while the CVI for the 6-weeks study period was considerably higher. Considering how these data differ from data reported from other studies with similar sampling intervals and study duration, it is difficult to draw any conclusions. Furthermore, the single day study consisted of five repeated samples per individual around the same time-point, so this represents the variation between five replicates [3]. The major advantage of the BV with a long study period is, that in addition to the influence of variation in a short period (such as diurnal rhythm), also seasonal effects are included.
One study reporting BV data for different populations was identified. This assessed gender-related differences, including in females using OC and not using OC, for fibrinogen (Clauss), t-PA activity, t-PA antigen and PAI-1 antigen. A higher CVI estimate was reported for fibrinogen (Clauss) in men than in women not using OC, while CVI estimates for t-PA activity and PAI-antigen were higher in men than in OC-using women. However, 95 % confidence intervals overlapped, except for PAI-antigen between men and women using OC. Further studies should be performed to investigate gender-related differences, as these have been demonstrated for other haemostasis-related measurands in studies with weekly sampling [11]. Further knowledge is also needed about BV in women using OC, because OC use is characterized by increased clotting factor levels, a reduction in coagulation inhibitors and changes in the fibrinolytic system [12], which could influence BV of related measurands.
In conclusion; based on our study, BV estimates for most haemostatic measurands derived from short- and long-term study designs are similar, with the exception for VWF and fibrinogen (Clauss). However, the short-term BV estimates reported in our study are derived from grade C quality studies and for most measurands, only single studies were identified. This is a limitation when assessing differences between short-term and long-term BV estimates and must also be considered when using these short-term BV data to inform on APS and for other BV applications. Further high-quality BV studies are therefore very welcome, especially for measurands where BV data are presently lacking.
Acknowledgments
We would like to thank the EFLM Technical Committee Biological Variation Database for the development of the tools used in this article.
-
Research ethics: Not applicable.
-
Informed consent: Not applicable.
-
Author contributions: All authors have accepted responsibility for the entire content of this manuscript and approved its submission.
-
Use of Large Language Models, AI and Machine Learning Tools: None declared.
-
Conflict of interest: The authors state no conflict of interest.
-
Research funding: Thanks to the Western Norway Regional Health Authority for supporting Ann Helen Kristoffersen with postdoctoral fellowship.
-
Data availability: Not applicable.
References
1. Hollestelle, MJ, Kristoffersen, AH, Idema, RN, Meijer, P, Sandberg, S, de Maat, MPM, et al.. Systematic review and meta-analysis of within-subject and between-subject biological variation data of coagulation and fibrinolytic measurands. Clin Chem Lab Med 2023;61:1470–80. https://doi.org/10.1515/cclm-2022-1207.Search in Google Scholar PubMed
2. Riese, H, Vrijkotte, TGM, Meijer, P, Kluft, C, De Geus, EJC. Covariance of metabolic and haemostatic risk indicators in men and women. Fibrinolysis Proteolysis 2001;14:1–12.10.1054/fipr.2001.0099Search in Google Scholar
3. Rosenson, RS, Tangney, CC, Hafner, JM. Intraindividual variability of fibrinogen levels and cardiovascular risk profile. Arterioscler Thromb 1994;14:1928–32. https://doi.org/10.1161/01.atv.14.12.1928.Search in Google Scholar PubMed
4. Aarsand, AK, Roraas, T, Fernandez-Calle, P, Ricos, C, Diaz-Garzon, J, Jonker, N, et al.. The biological variation data critical appraisal checklist: a standard for evaluating studies on biological variation. Clin Chem 2018;64:501–14. https://doi.org/10.1373/clinchem.2017.281808.Search in Google Scholar PubMed
5. Costongs, GM, Bas, BM, Janson, PC, Hermans, J, Brombacher, PJ, van Wersch, JW. Short-term and long-term intra-individual variations and critical differences of coagulation parameters. J Clin Chem Clin Biochem 1985;23:405–10. https://doi.org/10.1515/cclm.1985.23.7.405.Search in Google Scholar
6. Chen, Q, Shou, W, Wu, W, Guo, Y, Zhang, Y, Huang, C, et al.. Biological and analytical variations of 16 parameters related to coagulation screening tests and the activity of coagulation factors. Semin Thromb Hemost 2015;41:336–41. https://doi.org/10.1055/s-0034-1543994.Search in Google Scholar PubMed
7. Shou, W, Chen, Q, Wu, W, Cui, W. Biological variations of lupus anticoagulant, antithrombin, protein C, Protein S, and von Willebrand factor assays. Semin Thromb Hemost 2016;42:87–92. https://doi.org/10.1055/s-0035-1552588.Search in Google Scholar PubMed
8. Van Hoydonck, PG, Schouten, EG, Temme, EH. Reproducibility of blood markers of oxidative status and endothelial function in healthy individuals. Clin Chem 2003;49:963–5. https://doi.org/10.1373/49.6.963.Search in Google Scholar PubMed
9. van Mourik, JA, Boertjes, R, Huisveld, IA, Fijnvandraat, K, Pajkrt, D, van Genderen, PJ, et al.. von Willebrand factor propeptide in vascular disorders: a tool to distinguish between acute and chronic endothelial cell perturbation. Blood 1999;94:179–85. https://doi.org/10.1182/blood.v94.1.179.413k18_179_185.Search in Google Scholar
10. Gabay, C, Kushner, I. Acute-phase proteins and other systemic responses to inflammation. N Engl J Med 1999;340:448–54. https://doi.org/10.1056/nejm199902113400607.Search in Google Scholar PubMed
11. Aarsand, AK, Kristoffersen, AH, Sandberg, S, Stove, B, Coskun, A, Fernandez-Calle, P, et al.. The European Biological Variation Study (EuBIVAS): biological variation data for coagulation markers estimated by a Bayesian model. Clin Chem 2021;67:1259–70. https://doi.org/10.1093/clinchem/hvab100.Search in Google Scholar PubMed
12. Sandset, PM. Mechanisms of hormonal therapy related thrombosis. Thromb Res 2013;131 Suppl 1:S4–7. https://doi.org/10.1016/s0049-3848(13)70009-4.Search in Google Scholar
© 2025 the author(s), published by De Gruyter, Berlin/Boston
This work is licensed under the Creative Commons Attribution 4.0 International License.
Articles in the same Issue
- Frontmatter
- Editorials
- The journey to pre-analytical quality
- Manual tilt tube method for prothrombin time: a commentary on contemporary relevance
- Reviews
- From errors to excellence: the pre-analytical journey to improved quality in diagnostics. A scoping review
- Advancements and challenges in high-sensitivity cardiac troponin assays: diagnostic, pathophysiological, and clinical perspectives
- Opinion Paper
- Is it feasible for European laboratories to use SI units in reporting results?
- Perspectives
- What does cancer screening have to do with tomato growing?
- Computer simulation approaches to evaluate the interaction between analytical performance characteristics and clinical (mis)classification: a complementary tool for setting indirect outcome-based analytical performance specifications
- Genetics and Molecular Diagnostics
- Artificial base mismatches-mediated PCR (ABM-PCR) for detecting clinically relevant single-base mutations
- Candidate Reference Measurement Procedures and Materials
- Antiphospholipid IgG Certified Reference Material ERM®-DA477/IFCC: a tool for aPL harmonization?
- General Clinical Chemistry and Laboratory Medicine
- External quality assessment of the manual tilt tube technique for prothrombin time testing: a report from the IFCC-SSC/ISTH Working Group on the Standardization of PT/INR
- Simple steps to achieve harmonisation and standardisation of dried blood spot phenylalanine measurements and facilitate consistent management of patients with phenylketonuria
- Inclusion of pyridoxine dependent epilepsy in expanded newborn screening programs by tandem mass spectrometry: set up of first and second tier tests
- Analytical performance evaluation and optimization of serum 25(OH)D LC-MS/MS measurement
- Towards routine high-throughput analysis of fecal bile acids: validation of an enzymatic cycling method for the quantification of total bile acids in human stool samples on fully automated clinical chemistry analyzers
- Analytical and clinical evaluations of Snibe Maglumi® S100B assay
- Prevalence and detection of citrate contamination in clinical laboratory
- Reference Values and Biological Variations
- Temporal dynamics in laboratory medicine: cosinor analysis and real-world data (RWD) approaches to population chronobiology
- Establishing sex- and age-related reference intervals of serum glial fibrillary acid protein measured by the fully automated lumipulse system
- Hematology and Coagulation
- Performance of the automated digital cell image analyzer UIMD PBIA in white blood cell classification: a comparative study with sysmex DI-60
- Cancer Diagnostics
- Flow-cytometric MRD detection in pediatric T-ALL: a multicenter AIEOP-BFM consensus-based guided standardized approach
- Impact of biological and genetic features of leukemic cells on the occurrence of “shark fins” in the WPC channel scattergrams of the Sysmex XN hematology analyzers in patients with chronic lymphocytic leukemia
- Assessing the clinical applicability of dimensionality reduction algorithms in flow cytometry for hematologic malignancies
- Cardiovascular Diseases
- Evaluation of sex-specific 0-h high-sensitivity cardiac troponin T thresholds for the risk stratification of non-ST-segment elevation myocardial infarction
- Retraction
- The first case of Teclistamab interference with serum electrophoresis and immunofixation
- Letters to the Editor
- Is this quantitative test fit-for-purpose?
- Reply to “Is this quantitative test fit-for-purpose?”
- Short-term biological variation of coagulation and fibrinolytic measurands
- The first case of Teclistamab interference with serum electrophoresis and immunofixation
- Imlifidase: a new interferent on serum protein electrophoresis looking as a rare plasma cell dyscrasia
- Research on the development of image-based Deep Learning (DL) model for serum quality recognition
- Interference of hypertriglyceridemia on total cholesterol assay with the new CHOL2 Abbott method on Architect analyser
- Congress Abstracts
- 10th Annual Meeting of the Austrian Society for Laboratory Medicine and Clinical Chemistry (ÖGLMKC)
Articles in the same Issue
- Frontmatter
- Editorials
- The journey to pre-analytical quality
- Manual tilt tube method for prothrombin time: a commentary on contemporary relevance
- Reviews
- From errors to excellence: the pre-analytical journey to improved quality in diagnostics. A scoping review
- Advancements and challenges in high-sensitivity cardiac troponin assays: diagnostic, pathophysiological, and clinical perspectives
- Opinion Paper
- Is it feasible for European laboratories to use SI units in reporting results?
- Perspectives
- What does cancer screening have to do with tomato growing?
- Computer simulation approaches to evaluate the interaction between analytical performance characteristics and clinical (mis)classification: a complementary tool for setting indirect outcome-based analytical performance specifications
- Genetics and Molecular Diagnostics
- Artificial base mismatches-mediated PCR (ABM-PCR) for detecting clinically relevant single-base mutations
- Candidate Reference Measurement Procedures and Materials
- Antiphospholipid IgG Certified Reference Material ERM®-DA477/IFCC: a tool for aPL harmonization?
- General Clinical Chemistry and Laboratory Medicine
- External quality assessment of the manual tilt tube technique for prothrombin time testing: a report from the IFCC-SSC/ISTH Working Group on the Standardization of PT/INR
- Simple steps to achieve harmonisation and standardisation of dried blood spot phenylalanine measurements and facilitate consistent management of patients with phenylketonuria
- Inclusion of pyridoxine dependent epilepsy in expanded newborn screening programs by tandem mass spectrometry: set up of first and second tier tests
- Analytical performance evaluation and optimization of serum 25(OH)D LC-MS/MS measurement
- Towards routine high-throughput analysis of fecal bile acids: validation of an enzymatic cycling method for the quantification of total bile acids in human stool samples on fully automated clinical chemistry analyzers
- Analytical and clinical evaluations of Snibe Maglumi® S100B assay
- Prevalence and detection of citrate contamination in clinical laboratory
- Reference Values and Biological Variations
- Temporal dynamics in laboratory medicine: cosinor analysis and real-world data (RWD) approaches to population chronobiology
- Establishing sex- and age-related reference intervals of serum glial fibrillary acid protein measured by the fully automated lumipulse system
- Hematology and Coagulation
- Performance of the automated digital cell image analyzer UIMD PBIA in white blood cell classification: a comparative study with sysmex DI-60
- Cancer Diagnostics
- Flow-cytometric MRD detection in pediatric T-ALL: a multicenter AIEOP-BFM consensus-based guided standardized approach
- Impact of biological and genetic features of leukemic cells on the occurrence of “shark fins” in the WPC channel scattergrams of the Sysmex XN hematology analyzers in patients with chronic lymphocytic leukemia
- Assessing the clinical applicability of dimensionality reduction algorithms in flow cytometry for hematologic malignancies
- Cardiovascular Diseases
- Evaluation of sex-specific 0-h high-sensitivity cardiac troponin T thresholds for the risk stratification of non-ST-segment elevation myocardial infarction
- Retraction
- The first case of Teclistamab interference with serum electrophoresis and immunofixation
- Letters to the Editor
- Is this quantitative test fit-for-purpose?
- Reply to “Is this quantitative test fit-for-purpose?”
- Short-term biological variation of coagulation and fibrinolytic measurands
- The first case of Teclistamab interference with serum electrophoresis and immunofixation
- Imlifidase: a new interferent on serum protein electrophoresis looking as a rare plasma cell dyscrasia
- Research on the development of image-based Deep Learning (DL) model for serum quality recognition
- Interference of hypertriglyceridemia on total cholesterol assay with the new CHOL2 Abbott method on Architect analyser
- Congress Abstracts
- 10th Annual Meeting of the Austrian Society for Laboratory Medicine and Clinical Chemistry (ÖGLMKC)