Home The effect of ratios upon improving patient-based real-time quality control (PBRTQC) performance
Article
Licensed
Unlicensed Requires Authentication

The effect of ratios upon improving patient-based real-time quality control (PBRTQC) performance

  • Yuanyuan Li , Xiaoling Chen and Ying Zhao EMAIL logo
Published/Copyright: October 23, 2023

Abstract

Objectives

Large biological variation hinders application of patient-based real-time quality control (PBRTQC). The effect of analyte ratios on the ability of PBRTQC to improve error detection was investigated.

Methods

Four single analyte-ratio pairs (alanine aminotransferase [ALT] vs. ALT to aspartate aminotransferase ratio [RALT]; creatinine [Cr] vs. Cr to cystatin C ratio [RCr]; lactate dehydrogenase [LDH] vs. LDH to hydroxybutyrate dehydrogenase ratio [RLDH]; total bilirubin [TB] vs. TB to direct bilirubin ratio [RTB]) were chosen for comparison. Various procedures, including four conventional algorithms (moving average [MA], moving median [MM], exponentially weighted moving average [EWMA] and moving standard deviation [MSD]) were assessed. A new algorithm that monitors the number of defect reports per analytical run (NDR) was also evaluated.

Results

When a single analyte and calculated ratio used the same PBRTQC parameters, fewer samples were needed to detect systematic errors (SE) by taking ratios (p<0.05). Application of ratios in MA, MM and EWMA significantly enhanced their ability to detect SE. The influence of ratio on random error (RE) detection depended upon the analytes and PBRTQC parameters, as consistent advantage was not demonstrated. The NDR method performed well when appropriate parameters were used, but was only effective for unilateral SE. Rearrangement of sample order led to a significant deterioration of conventional algorithms’ performance, while NDR remained almost unaffected.

Conclusions

For analytes with large variation and poor PBRTQC performance, using ratios as PBRTQC indexes may significantly improve performance and achieve better anti-interference ability, providing a new class of monitoring indicators for PBRTQC.


Corresponding author: Ying Zhao, Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, P.R. China; Key Laboratory of Clinical In Vitro Diagnostic Techniques of Zhejiang Province, Hangzhou, P.R. China; and Institute of Laboratory Medicine, Zhejiang University, Hangzhou, P.R. China, E-mail:

Funding source: Natural Science Foundation of China of Zhejiang Province

Award Identifier / Grant number: LGC22H200001

Funding source: National Key Technologies R&D Program, Ministry of Science and Technology of the People's Republic of China

Award Identifier / Grant number: grant numbers 2022YFC3602300, 2022YFC3602301

Acknowledgments

We thank Elixigen Corporation (Huntington Beach, California, USA) for helping in proofreading and editing the English of final manuscript.

  1. Research ethics: This study was approved by the Ethics Committee of the First Affiliated Hospital, Zhejiang University School of Medicine (Ethics Approval Ref: 2022-460). The study was conducted in accordance with the Declaration of Helsinki (as revised in 2013).

  2. Informed consent: Not applicable.

  3. Author contributions: Yuanyuan Li designed the study and wrote the manuscript; Yuanyuan Li and Xiaoling Chen analyzed data; Xiaoling Chen collected data; Ying Zhao supervised the study and reviewed the manuscript. All the authors have accepted responsibility for the entire content of this submitted manuscript and have approved the submission.

  4. Competing interests: Authors state no conflict of interest.

  5. Research funding: This work was supported by Natural Science Foundation of China of Zhejiang Province (LGC22H200001) and National Key Technologies R&D Program provided by Ministry of Science and Technology of the People’s Republic of China (Project Grant: 2022YFC3602300, Sub-project Grant: 2022YFC3602301).

  6. Data availability: The raw data can be obtained on request from the corresponding author.

References

1. van Rossum, HH, Bietenbeck, A, Cervinski, MA, Katayev, A, Loh, TP, Badrick, TC. Benefits, limitations, and controversies on patient-based real-time quality control (PBRTQC) and the evidence behind the practice. Clin Chem Lab Med 2021;59:1213–20. https://doi.org/10.1515/cclm-2021-0072.Search in Google Scholar PubMed

2. Loh, TP, Bietenbeck, A, Cervinski, MA, van Rossum, HH, Katayev, A, Badrick, T, et al.. Recommendation for performance verification of patient-based real-time quality control. Clin Chem Lab Med 2020;58:1205–13. https://doi.org/10.1515/cclm-2019-1024.Search in Google Scholar PubMed

3. Parvin, CA. What’s new in laboratory statistical quality control guidance? The 4th edition of CLSI C24, statistical quality control for quantitative measurement procedures: principles and definitions. J Appl Lab Med 2017;1:581–4. https://doi.org/10.1373/jalm.2016.022269.Search in Google Scholar PubMed

4. Parvin, CA. Planning statistical quality control to minimize patient risk: it’s about time. Clin Chem 2018;64:249–50. https://doi.org/10.1373/clinchem.2017.282038.Search in Google Scholar PubMed

5. Tolan, NV, Parnas, ML, Baudhuin, LM, Cervinski, MA, Chan, AS, Holmes, DT, et al.. “Big data” in laboratory medicine. Clin Chem 2015;61:1433–40. https://doi.org/10.1373/clinchem.2015.248591.Search in Google Scholar PubMed

6. Liu, J, Tan, CH, Badrick, T, Loh, TP. Moving sum of number of positive patient result as a quality control tool. Clin Chem Lab Med 2017;55:1709–14. https://doi.org/10.1515/cclm-2016-0950.Search in Google Scholar PubMed

7. van Rossum, HH, Kemperman, H. Optimization and validation of moving average quality control procedures using bias detection curves and moving average validation charts. Clin Chem Lab Med 2017;55:218–24. https://doi.org/10.1515/cclm-2016-0270.Search in Google Scholar PubMed

8. Liu, J, Tan, CH, Badrick, T, Loh, TP. Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision. Clin Biochem 2018;52:112–6. https://doi.org/10.1016/j.clinbiochem.2017.10.009.Search in Google Scholar PubMed

9. Duan, X, Wang, B, Zhu, J, Zhang, C, Jiang, W, Zhou, J, et al.. Regression-adjusted real-time quality control. Clin Chem 2021;67:1342–50. https://doi.org/10.1093/clinchem/hvab115.Search in Google Scholar PubMed

10. Algeciras-Schimnich, A, Bruns, DE, Boyd, JC, Bryant, SC, La Fortune, KA, Grebe, SK. Failure of current laboratory protocols to detect lot-to-lot reagent differences: findings and possible solutions. Clin Chem 2013;59:1187–94. https://doi.org/10.1373/clinchem.2013.205070.Search in Google Scholar PubMed

11. Li, Y, Yu, Q, Zhang, X, Chen, X. Comparison and optimization of various moving patient-based real-time quality control procedures for serum sodium. J Clin Lab Anal 2021;35:e23985. https://doi.org/10.1002/jcla.23985.Search in Google Scholar PubMed PubMed Central

12. Duan, X, Wang, B, Zhu, J, Shao, W, Wang, H, Shen, J, et al.. Assessment of patient-based real-time quality control algorithm performance on different types of analytical error. Clin Chim Acta 2020;511:329–35. https://doi.org/10.1016/j.cca.2020.10.006.Search in Google Scholar PubMed

13. Bietenbeck, A, Cervinski, MA, Katayev, A, Loh, TP, van Rossum, HH, Badrick, T. Understanding patient-based real-time quality control using simulation modeling. Clin Chem 2020;66:1072–83. https://doi.org/10.1093/clinchem/hvaa094.Search in Google Scholar PubMed

14. Ng, D, Polito, FA, Cervinski, MA. Optimization of a moving averages program using a simulated annealing algorithm: the goal is to monitor the process not the patients. Clin Chem 2016;62:1361–71. https://doi.org/10.1373/clinchem.2016.257055.Search in Google Scholar PubMed

15. He, L, Bai, Y, Wang, W, Wang, Z. The application of quality specifications derived from biological variation in routine chemistry external quality assessment and internal quality control. Chin J Lab Med 2012;35:531–7.Search in Google Scholar

16. Jorgensen, LM, Hansen, SI, Petersen, PH, Soletormos, G. Median of patient results as a tool for assessment of analytical stability. Clin Chim Acta 2015;446:186–91. https://doi.org/10.1016/j.cca.2015.04.024.Search in Google Scholar PubMed

17. Badrick, T, Bietenbeck, A, Katayev, A, van Rossum, HH, Loh, TP, Cervinski, MA, et al.. Implementation of patient-based real-time quality control. Crit Rev Clin Lab Sci 2020;57:532–47. https://doi.org/10.1080/10408363.2020.1765731.Search in Google Scholar PubMed

18. Charuruks, N. Sigma metrics across the total testing process. Clin Lab Med 2017;37:97–117. https://doi.org/10.1016/j.cll.2016.09.009.Search in Google Scholar PubMed


Supplementary Material

This article contains supplementary material (https://doi.org/10.1515/cclm-2023-0865).


Received: 2023-08-07
Accepted: 2023-10-05
Published Online: 2023-10-23
Published in Print: 2024-03-25

© 2023 Walter de Gruyter GmbH, Berlin/Boston

Articles in the same Issue

  1. Frontmatter
  2. Editorial
  3. Value-based laboratory medicine: the time is now
  4. Review
  5. Cardiovascular risk evaluation in pregnancy: focus on cardiac specific biomarkers
  6. Opinion Papers
  7. From volume to value: a watershed moment for the clinical laboratory
  8. APS calculator: a data-driven tool for setting outcome-based analytical performance specifications for measurement uncertainty using specific clinical requirements and population data
  9. Guidelines and Recommendations
  10. Analytical interference of intravascular contrast agents with clinical laboratory tests: a joint guideline by the ESUR Contrast Media Safety Committee and the Preanalytical Phase Working Group of the EFLM Science Committee
  11. Genetics and Molecular Diagnostics
  12. Specifications of qPCR based epigenetic immune cell quantification
  13. General Clinical Chemistry and Laboratory Medicine
  14. An appraisal of the practice of duplicate testing for the detection of irregular analytical errors
  15. Machine learning-based nonlinear regression-adjusted real-time quality control modeling: a multi-center study
  16. The effect of ratios upon improving patient-based real-time quality control (PBRTQC) performance
  17. Diagnostic sample transport via pneumatic tube systems: data logger and their algorithms are sensitive to transport effects
  18. Ambulatory human chorionic gonadotrophin (hCG) testing: a verification of two hCG point of care devices
  19. Monitoring patients with celiac disease on gluten free diet: different outcomes comparing three tissue transglutaminase IgA assays
  20. Verification, implementation and harmonization of automated chemiluminescent immunoassays for MPO- and PR3-ANCA detection
  21. Performance evaluation of a novel platelet count parameter, hybrid platelet count, on the BC-780 automated hematology analyzer
  22. Reference Values and Biological Variations
  23. Pediatric reference intervals for serum neurofilament light and glial fibrillary acidic protein using the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) cohort
  24. Biological variation of serum neopterin concentrations in apparently healthy individuals
  25. Short-term biological variation of serum tryptase
  26. Cancer Diagnostics
  27. Quantification of the lung cancer tumor marker CYFRA 21-1 using protein precipitation, immunoaffinity bottom-up LC-MS/MS
  28. Cardiovascular Diseases
  29. Prognostic significance of chronic myocardial injury diagnosed by three different cardiac troponin assays in patients admitted with suspected acute coronary syndrome
  30. Deep learning-based NT-proBNP prediction from the ECG for risk assessment in the community
  31. Diabetes
  32. Innovations in HbA1c analysis: finding the balance between speed and accuracy. An investigation of a potential new Secondary Reference Measurement Procedure for the IFCC
  33. Precise glucose measurement in sodium fluoride-citrate plasma affects estimates of prevalence in diabetes and prediabetes
  34. Infectious Diseases
  35. Urinary phenotyping of SARS-CoV-2 infection connects clinical diagnostics with metabolomics and uncovers impaired NAD+ pathway and SIRT1 activation
  36. Letters to the Editor
  37. Analytical performance specifications for measurement uncertainty in therapeutic monitoring of immunosuppressive drugs
  38. Capillary blood collection tubes containing serum separator gel result in lower measurements of oestradiol and total testosterone
  39. Re.: Louise Guillaume et al. Biological variation of CA 15-3, CA 125 and HE 4 on lithium heparinate plasma in apparently healthy Caucasian volunteers. Clin Chem Lab Med 2023;61(7):1319–1326; https://doi.org/10.1515/cclm-2022-0966
  40. A comparison of cannabidiol (CBD) concentrations in venous vs. fingertip-capillary blood
  41. Identification of sulfamethoxazole’s residues in sulfamethoxazole induced kidney stones by mass spectrometry
  42. Impact of different preservation methods on urinary red blood cell counts
  43. Diagnosis of IRAK-4-deficiency by flow cytometric measurement of IκB-α degradation
Downloaded on 8.10.2025 from https://www.degruyterbrill.com/document/doi/10.1515/cclm-2023-0865/html
Scroll to top button