In 2008, the Editors of the journal Clinical Chemistry and Laboratory Medicine (CCLM) and de Gruyter Publishers established the “CCLM Award for the Most Cited Paper Recently Published”. The Award is given out every 3 years, and the last time it was presented was at the IFCC WorldLab Berlin in 2011.
The award honors the most cited original article published in the last 3 years and rewards the authors of articles that generate high interest among the Journal’s readership.
In 2014, the prize goes to Dr. Walter Michael Halbmayer and Dr. Guenter Weigel (Institute of Laboratory Medicine, Municipal Hospital Hietzing-Rosenhuegel, Vienna, Austria, and Central Institute of Medical and Chemical Laboratory Diagnostics, University Hospital – State Hospital Innsbruck, Innsbruck, Austria), co-authors of the article: “Interference of the new oral anticoagulant dabigatran with frequently used coagulation tests” published in CCLM 2012:50(9):1601–1605. The Award was presented during the Opening Ceremony of the 3rd EFLM-UEMS Congress – EuroLabFocus 2014 “Laboratory Medicine at the Clinical Interface” organized in Liverpool from October 7–10, 2014. The awardees were presented an award certificate, a 1-year free online subscription to the Journal and a monetary prize.
Here is the brief description of the paper provided by the two co-authors:
From 2010 to 2011 we completed a multicenter-in-vitro-trial with CE labeled, lyophilized, dabigatran-spiked plasma samples in coagulation laboratories of six major Austrian hospitals under routine conditions using standard reagents and analyzers. Dabigatran led to a dose-dependent prolongation of the clotting times in coagulometric tests and influenced the majority of the parameters measured. Statistically significant interference could be observed with the prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen according to Clauss and PT/aPTT-based assays such as extrinsic/intrinsic factors and APC-resistance test as well as lupus anticoagulant testing. Even non-clotting tests, such as the colorimetric factor XIII activity assay and to a minor extent the amidolytic antithrombin activity assay (via factor IIa) were affected. Our data demonstrated that laboratories should expect to observe strong interferences of coagulation tests with increasing concentrations of dabigatran. Our paper was intended as an early warning for medical laboratories and turned out to be true in the daily clinical routine especially in the elderly, patients with renal impairment as well as patients whose blood was drawn at peak levels of dabigatran.
Dr. Walter Michael Halbmayer
Dr. Guenter Weigel
Articles receiving many citations significantly contribute to increasing not only the impact factor but above all the overall quality of a journal. We are confident that the efforts to improve the quality of articles published in CCLM and the decision to assure continuity of the Award in times marked by increasing economic pressure will be acknowledged and welcomed by the scientific community.
©2014 by De Gruyter
Articles in the same Issue
- Frontmatter
- Editorials
- CCLM Award for The Most Cited Paper Recently Published
- Laboratory preparedness to face infectious outbreaks. Ebola and beyond
- Reviews
- Determination of reference limits: statistical concepts and tools for sample size calculation
- Recent advances in physiological lipoprotein metabolism
- New laboratory markers for the management of rheumatoid arthritis patients
- General Clinical Chemistry and Laboratory Medicine
- The impact of repeat-testing of common chemistry analytes at critical concentrations
- Performance of CKD-EPI equation to estimate glomerular filtration rate as compared to MDRD equation in South Brazilian individuals in each stage of renal function
- The serum uromodulin level is associated with kidney function
- Efficient assessment of peripheral blood lymphocytosis in adults: developing new thresholds for blood smear review by pathologists
- Performance evaluation of Sysmex XN hematology analyzer in umbilical cord blood: a comparison study with Sysmex XE-2100
- UF-1000i: validation of the body fluid mode for counting cells in body fluids
- Newborn screening for haemoglobinopathies by high performance liquid chromatography (HPLC): diagnostic utility of different approaches in resource-poor settings
- Progressive chromogenic anti-factor Xa assay and its use in the classification of antithrombin deficiencies
- Reference Values and Biological Variations
- Thyroid-stimulating hormone reference range and factors affecting it in a nationwide random sample
- Reference ranges for serum β-trace protein in neonates and children younger than 1 year of age
- A multicenter nationwide reference intervals study for common biochemical analytes in Turkey using Abbott analyzers
- Serum reference intervals of homoarginine, ADMA, and SDMA in the Study of Health in Pomerania
- Cancer Diagnostics
- Low SOX17 expression: prognostic significance in de novo acute myeloid leukemia with normal cytogenetics
- Results of first proficiency test for KRAS testing with formalin-fixed, paraffin-embedded cell lines in China
- Aberrant hypermethylation of CTNNA1 gene is associated with higher IPSS risk in patients with myelodysplastic syndrome
- Cardiovascular Diseases
- Association between SNP rs13376333 and rs1131820 in the KCNN3 gene and atrial fibrillation in the Chinese Han population
- Acknowledgment
- Acknowledgment
- Letters to the Editor
- Interference in thyroid hormones with Roche immunoassays: an unfinished story
- Discrepant results in plasma, but not serum in the Beckman Coulter DxI Access HYPERsensitive hTSH 3rd generation assay affect the management of differentiated thyroid cancer and hyperthyroid patients
- Improper serum separation on gel tubes: a trivial laboratory problem or an indicator of monoclonal gammopathy?
- Analytical comparison of the new point-of-care troponin T immunoassay on AQT90Flex® analyzer (Radiometer) and the high-sensitivity troponin T immunoassay on ModularE170® (Roche Diagnostics)
- Performance characteristics of the enzymatic Abbott Architect HbA1c whole blood assay
- Multi-center proficiency tests for Lab-MELD score diagnostics to improve the quality and safety for patients awaiting liver transplantation
- The apolipoprotein B/apolipoprotein A-I ratio in healthy men with normolipidemia: limits of variation and relationship with other lipid parameters
- Validity and reliability of the 13C-methionine breath test for the detection of moderate hyperhomocysteinemia in Mexican adults; statistical issues in validity and reliability analysis
- Enzymatic and endpoint methods yield comparable adenosine deaminase activity in pleural fluid samples
- Congress Abstract
- 5th Italian GREAT Network Congress
- Congress of Laboratory Medicine and Clinical Chemistry
Articles in the same Issue
- Frontmatter
- Editorials
- CCLM Award for The Most Cited Paper Recently Published
- Laboratory preparedness to face infectious outbreaks. Ebola and beyond
- Reviews
- Determination of reference limits: statistical concepts and tools for sample size calculation
- Recent advances in physiological lipoprotein metabolism
- New laboratory markers for the management of rheumatoid arthritis patients
- General Clinical Chemistry and Laboratory Medicine
- The impact of repeat-testing of common chemistry analytes at critical concentrations
- Performance of CKD-EPI equation to estimate glomerular filtration rate as compared to MDRD equation in South Brazilian individuals in each stage of renal function
- The serum uromodulin level is associated with kidney function
- Efficient assessment of peripheral blood lymphocytosis in adults: developing new thresholds for blood smear review by pathologists
- Performance evaluation of Sysmex XN hematology analyzer in umbilical cord blood: a comparison study with Sysmex XE-2100
- UF-1000i: validation of the body fluid mode for counting cells in body fluids
- Newborn screening for haemoglobinopathies by high performance liquid chromatography (HPLC): diagnostic utility of different approaches in resource-poor settings
- Progressive chromogenic anti-factor Xa assay and its use in the classification of antithrombin deficiencies
- Reference Values and Biological Variations
- Thyroid-stimulating hormone reference range and factors affecting it in a nationwide random sample
- Reference ranges for serum β-trace protein in neonates and children younger than 1 year of age
- A multicenter nationwide reference intervals study for common biochemical analytes in Turkey using Abbott analyzers
- Serum reference intervals of homoarginine, ADMA, and SDMA in the Study of Health in Pomerania
- Cancer Diagnostics
- Low SOX17 expression: prognostic significance in de novo acute myeloid leukemia with normal cytogenetics
- Results of first proficiency test for KRAS testing with formalin-fixed, paraffin-embedded cell lines in China
- Aberrant hypermethylation of CTNNA1 gene is associated with higher IPSS risk in patients with myelodysplastic syndrome
- Cardiovascular Diseases
- Association between SNP rs13376333 and rs1131820 in the KCNN3 gene and atrial fibrillation in the Chinese Han population
- Acknowledgment
- Acknowledgment
- Letters to the Editor
- Interference in thyroid hormones with Roche immunoassays: an unfinished story
- Discrepant results in plasma, but not serum in the Beckman Coulter DxI Access HYPERsensitive hTSH 3rd generation assay affect the management of differentiated thyroid cancer and hyperthyroid patients
- Improper serum separation on gel tubes: a trivial laboratory problem or an indicator of monoclonal gammopathy?
- Analytical comparison of the new point-of-care troponin T immunoassay on AQT90Flex® analyzer (Radiometer) and the high-sensitivity troponin T immunoassay on ModularE170® (Roche Diagnostics)
- Performance characteristics of the enzymatic Abbott Architect HbA1c whole blood assay
- Multi-center proficiency tests for Lab-MELD score diagnostics to improve the quality and safety for patients awaiting liver transplantation
- The apolipoprotein B/apolipoprotein A-I ratio in healthy men with normolipidemia: limits of variation and relationship with other lipid parameters
- Validity and reliability of the 13C-methionine breath test for the detection of moderate hyperhomocysteinemia in Mexican adults; statistical issues in validity and reliability analysis
- Enzymatic and endpoint methods yield comparable adenosine deaminase activity in pleural fluid samples
- Congress Abstract
- 5th Italian GREAT Network Congress
- Congress of Laboratory Medicine and Clinical Chemistry