Abstract
To restore walking after transfemoral amputation, various actuated exoprostheses have been developed, which control the knee torque actively or via variable damping. In both cases, an important issue is to find the appropriate control that enables user-dominated gait. Recently, we suggested a generic method to deduce intended motion of impaired or amputated limbs from residual human body motion. Based on interjoint coordination in physiological gait, statistical regression is used to estimate missing motion. In a pilot study, this complementary limb motion estimation (CLME) strategy is applied to control an active knee exoprosthesis. A motor-driven prosthetic knee with one degree of freedom has been realized, and one above-knee amputee has used it with CLME. Performed tasks are walking on a treadmill and alternating stair ascent and descent. The subject was able to walk on the treadmill at varying speeds, but needed assistance with the stairs, especially to descend. The promising results with CLME are compared with the subject's performance with her own prosthesis, the C-Leg from Otto Bock.
©2011 by Walter de Gruyter Berlin New York
Articles in the same Issue
- Publisher’s Note
- Publisher’s Note
- Editorial
- Technically assisted rehabilitation
- Low-cost monitoring of patients during unsupervised robot/computer assisted motivating stroke rehabilitation
- MotionTherapy@Home – First results of a clinical study with a novel robotic device for automated locomotion therapy at home
- Amplifier design for EMG recording from stimulation electrodes during functional electrical stimulation leg cycling ergometry
- OrthoJacket: an active FES-hybrid orthosis for the paralysed upper extremity
- Complementary limb motion estimation for the control of active knee prostheses
- Original Articles
- Modeling of load transmission and distribution of deformation energy before and after healing of basal dental implants in the human mandible
- A physical model of the thermodilution method: influences of the variations of experimental setup on the accuracy of flow rate estimation
- Biometric measurements inside the model eye using a two wavelengths Fourier domain low coherence interferometer
Articles in the same Issue
- Publisher’s Note
- Publisher’s Note
- Editorial
- Technically assisted rehabilitation
- Low-cost monitoring of patients during unsupervised robot/computer assisted motivating stroke rehabilitation
- MotionTherapy@Home – First results of a clinical study with a novel robotic device for automated locomotion therapy at home
- Amplifier design for EMG recording from stimulation electrodes during functional electrical stimulation leg cycling ergometry
- OrthoJacket: an active FES-hybrid orthosis for the paralysed upper extremity
- Complementary limb motion estimation for the control of active knee prostheses
- Original Articles
- Modeling of load transmission and distribution of deformation energy before and after healing of basal dental implants in the human mandible
- A physical model of the thermodilution method: influences of the variations of experimental setup on the accuracy of flow rate estimation
- Biometric measurements inside the model eye using a two wavelengths Fourier domain low coherence interferometer