Self-monitoring of blood glucose with a focus on analytical quality: an overview
-
Gunn B.B. Kristensen
Abstract
Self-monitoring of blood glucose (SMBG) has been available for patients with diabetes for more than 30 years. Today, SMBG is an important component in diabetes management, helping patients achieve and maintain normal blood glucose concentrations. Implementation of SMBG as an effective glycaemic control tool requires that instruments have acceptable analytical quality, that the patients are educated in using them, and that actions are taken upon the results. This paper gives an overview of SMBG, including the history, clinical utility, principles of measurement and several aspects of analytical quality of SMBG. The latter comprises a standardised evaluation of SMBG performance, quality specifications as well as different approaches to monitor the quality of SMBG performance.
Clin Chem Lab Med 2010;48:963–72.
©2010 by Walter de Gruyter Berlin New York
Articles in the same Issue
- HIGHLIGHT: LABORATORY DIAGNOSTICS IN THE THIRD MILLENIUM: WHERE, HOW AND WHY
- Editorial
- Foreword
- Reviews
- Roots, development and future directions of laboratory medicine
- The “hospital central laboratory”: automation, integration and clinical usefulness
- Clinical pathology services: remapping our strategic itinerary
- Stat laboratory testing: integration or autonomy?
- Point-of-care testing in critical care: the clinician's point of view
- Reproductive-endocrine point-of-care testing: current status and limitations
- Laboratory testing in pharmacies
- Laboratory testing during critical care transport: point-of-care testing in air ambulances
- Self-monitoring of blood glucose with a focus on analytical quality: an overview
- Molecular diagnostics: between chips and customized medicine
- Evaluating laboratory diagnostic tests and translational research
- Integrated diagnostics: a conceptual framework with examples
- General Clinical Chemistry and Laboratory Medicine
- The European Register of Specialists in Clinical Chemistry and Laboratory Medicine: Guide to the Register, Version 3-2010
- The prevalence of preanalytical errors in a Croatian ISO 15189 accredited laboratory
- Indicators and quality specifications for strategic and support processes related to the clinical laboratory: four years' experience
- SKML-Quality Mark for point-of-care test (POCT) glucose meters and glucose meters for home-use
- PATHFAST™ NT-proBNP (N-terminal-pro B type natriuretic peptide): a multicenter evaluation of a new point-of-care assay
- Clinical implication of plasma neutrophil gelatinase-associated lipocalin (NGAL) concentrations in patients with advanced carotid atherosclerosis
- Evaluation of the TEST 1 erythrocyte sedimentation rate system and intra- and inter-laboratory quality control using new latex control materials
- Letter to the Editor
- Phlebotomy site haemolysis rates vary inversely with workload
Articles in the same Issue
- HIGHLIGHT: LABORATORY DIAGNOSTICS IN THE THIRD MILLENIUM: WHERE, HOW AND WHY
- Editorial
- Foreword
- Reviews
- Roots, development and future directions of laboratory medicine
- The “hospital central laboratory”: automation, integration and clinical usefulness
- Clinical pathology services: remapping our strategic itinerary
- Stat laboratory testing: integration or autonomy?
- Point-of-care testing in critical care: the clinician's point of view
- Reproductive-endocrine point-of-care testing: current status and limitations
- Laboratory testing in pharmacies
- Laboratory testing during critical care transport: point-of-care testing in air ambulances
- Self-monitoring of blood glucose with a focus on analytical quality: an overview
- Molecular diagnostics: between chips and customized medicine
- Evaluating laboratory diagnostic tests and translational research
- Integrated diagnostics: a conceptual framework with examples
- General Clinical Chemistry and Laboratory Medicine
- The European Register of Specialists in Clinical Chemistry and Laboratory Medicine: Guide to the Register, Version 3-2010
- The prevalence of preanalytical errors in a Croatian ISO 15189 accredited laboratory
- Indicators and quality specifications for strategic and support processes related to the clinical laboratory: four years' experience
- SKML-Quality Mark for point-of-care test (POCT) glucose meters and glucose meters for home-use
- PATHFAST™ NT-proBNP (N-terminal-pro B type natriuretic peptide): a multicenter evaluation of a new point-of-care assay
- Clinical implication of plasma neutrophil gelatinase-associated lipocalin (NGAL) concentrations in patients with advanced carotid atherosclerosis
- Evaluation of the TEST 1 erythrocyte sedimentation rate system and intra- and inter-laboratory quality control using new latex control materials
- Letter to the Editor
- Phlebotomy site haemolysis rates vary inversely with workload