Home Development and preparation of a new serum protein reference material: feasibility studies and processing
Article
Licensed
Unlicensed Requires Authentication

Development and preparation of a new serum protein reference material: feasibility studies and processing

  • Ingrid Zegers , Wiebke Schreiber , Sarah Linstead , Manfred Lammers , Matthew McCusker , Amalia Muñoz , Yoshi Itoh , Giampaolo Merlini , Stefanie Trapmann , Hendrik Emons , Joanna Sheldon and Heinz Schimmel
Published/Copyright: April 8, 2010

Abstract

Background: The availability of matrix reference materials is essential for the standardisation of (immuno)assays used to measure proteins. The reference material ERM-DA470 (previously called CRM470) certified in 1993 has led to a large degree of harmonisation of these assays. A new serum protein reference material has now been produced (ERM-DA470k). It is intended to replace ERM-DA470, and will additionally be certified for β2-microglobulin (B2M).

Methods: Serum from 390 healthy donors was pooled and processed so as to stabilise, delipidate and ‘maturate’ it. Purified C-reactive protein (CRP) and recombinant B2M were added. Pilot batches were produced to study the stability, homogeneity, and commutability of the material. On the basis of the results with the trial batches it was decided to proceed with the processing of the main batch of a candidate reference material.

Results: Two pilot batches were produced and the processed and spiked serum lyophilised after filling (1 mL). The B2M in the material was shown to be stable and commutable. For CRP, it was discovered that freeze-drying led to a decrease in measurable protein. The main batch of candidate reference material was produced and fulfilled the required criteria in terms of optical transparency, homogeneity and stability.

Conclusions: A new serum protein reference material has been produced with the properties required for a serum protein reference material for 14 proteins. An apparent loss of CRP of approximately 20% was observed upon freeze-drying of the material.

Clin Chem Lab Med 2010;48:805–13.


Corresponding author: Ingrid Zegers, IRMM, JRC, European Commission, Retieseweg 111, 2440 Geel, Belgium Phone: +32 14 571 920, Fax: +32 14 571 548,

Received: 2010-1-6
Accepted: 2010-2-1
Published Online: 2010-04-8
Published in Print: 2010-06-01

©2010 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Editorials
  2. The “Obamanomics”: a revolution in laboratory diagnostics
  3. Skeletal muscle biomarkers: not new but still interesting diagnostic tools
  4. Necessity for high-quality reference materials in the harmonization of laboratory assays
  5. Reviews
  6. Rhabdomyolysis: historical background, clinical, diagnostic and therapeutic features
  7. Biochemical markers of muscular damage
  8. Minireview
  9. Interpretation of serum parathyroid hormone concentrations in dialysis patients: what do the KDIGO guidelines change for the clinical laboratory?
  10. Guidelines and Recommendations
  11. 2010 Consensus statement on the worldwide standardization of the hemoglobin A1c measurement
  12. Genetics and Molecular Diagnostics
  13. Development of a low-cost real-time reverse transcriptase-polymerase chain reaction technique for the detection and quantification of hepatitis C viral load
  14. Microsatellite polymorphisms in intron 2 of the toll-like receptor 2 gene and their association with susceptibility to pulmonary tuberculosis in Han Chinese
  15. Evaluation of a panel of circulating DNA, RNA and protein potential markers for pathologies of pregnancy
  16. General Clinical Chemistry and Laboratory Medicine
  17. Traceability of values for catalytic activity concentration of enzymes: a Certified Reference Material for aspartate transaminase
  18. Development and preparation of a new serum protein reference material: feasibility studies and processing
  19. A WHO Reference Reagent for the Serum Transferrin Receptor (sTfR): international collaborative study to evaluate a recombinant soluble transferrin receptor preparation
  20. Hyperhomocysteinemia is not associated with reduced bone quality in humans with hip osteoarthritis
  21. Diagnostic performance of anti-citrullinated peptide antibodies for the diagnosis of rheumatoid arthritis: the relevance of likelihood ratios
  22. New quantitative electrochemiluminescence method (ECLIA) for interleukin-6 (IL-6) measurement
  23. Evaluation of cell counting and leukocyte differentiation in cerebrospinal fluid controls using hematology analyzers by the German Society for Clinical Chemistry and Laboratory Medicine
  24. Reference Values and Biological Variations
  25. The relationship of coffee and green tea consumption with high-sensitivity C-reactive protein in Japanese men and women
  26. Cancer Diagnostics
  27. Potential biomarkers for esophageal carcinoma detected by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
  28. Identification of candidate molecular markers predicting chemotherapy resistance in non-small cell lung cancer
  29. Factors affecting soluble mesothelin related protein levels in an asbestos-exposed population
  30. Cardiovascular Diseases
  31. Dynamic changes in N-terminal pro-brain natriuretic peptide in acute coronary syndromes treated with percutaneous coronary intervention: a marker of ischemic burden, reperfusion and outcome
  32. Performance characteristics of a microfluidic Lab-on-Chip electrophoresis system for high-density lipoprotein (HDL) subfraction separation and measurement
  33. Letters to the Editor
  34. Hemolysis correction factor in the measurement of serum neuron-specific enolase
  35. Serum paraoxonase-1 activity and genetic polymorphisms: common errors in measurement and interpretation of results
  36. Neuropharmacology of schizophrenia: is there a role for leptin?
  37. Relationship between serum concentrations of keratin-18 and apoptosis in chronic hepatitis C
Downloaded on 6.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2010.166/pdf
Scroll to top button