Home Medicine Der Einfluss der Knochenmineraldichte und des Verankerungsverfahrens auf die Primärstabilität von zementfrei implantierten Tibiakomponenten / The influence of bone quality and the fixation procedure on the primary stability of cementless implanted tibial plateaus
Article
Licensed
Unlicensed Requires Authentication

Der Einfluss der Knochenmineraldichte und des Verankerungsverfahrens auf die Primärstabilität von zementfrei implantierten Tibiakomponenten / The influence of bone quality and the fixation procedure on the primary stability of cementless implanted tibial plateaus

  • Carsten Boos , Klaus Fink , Peter Stomberg , Wolfgang Koeller , Bernd-Wolfgang Igl and Martin Russlies
Published/Copyright: April 16, 2008
Biomedical Engineering / Biomedizinische Technik
From the journal Volume 53 Issue 2

Zusammenfassung

Hintergrund: In der Gesamtschau prospektiver Studien nach zementfrei bzw. zementiert durchgeführter primärer Kniegelenksendoprothetik im Zeitraum 1988–2004 liegt die aseptische Lockerungsrate von zementiert implantierten Prothesen mit fixierten Meniskallagern in einem Zeitintervall von 4–14 Jahren zwischen 2% und 6%. Dagegen weisen zementfrei implantierte Prothesen in einem Zeitintervall von 4–10 Jahren Lockerungen von bis zu 28% auf. Ob diese Ergebnisse auf einer gestörten initialen Osteointegration infolge einer unzureichenden Primärstabilität beruhen und welchen Einfluss die tibiale Knochenqualität oder das tibiale Fixationsverfahren hierauf haben, ist bisher nicht untersucht worden.

Material und Methode: In sechs paarigen Leichentibiaköpfen wurde ein Tibiaplateau verschraubt und unverschraubt press-fit implantiert. Die Stabilitätsuntersuchung erfolgte unter exzentrischer axialer Belastung, Scherung und Torsion.

Ergebnisse: Die durchschnittlichen betraglichen Relativbewegungen am medialen Plateau unter axialer Belastung unterschieden sich deutlich zwischen verschraubter und unverschraubter Version (p=0,016). Gleiches gilt für die Rotation medial (p=0,015). Die Knochendichte der Tibiametaphysen hatte keinen Effekt auf die Primärstabilität des zementfrei implantierten Tibiaplateaus.

Schlussfolgerung: Bei Einsatz von zementfrei implantierten Knieendoprothesen erscheint die Tibiaplateaufixierung durch eine zusätzliche Verschraubung – neben einer einwandfreien Press-fit- und Form-fit-Konfektionierung des Tibiakopfes – unverzichtbar, um eine ungestörte Osteointegration unter physiologischer axialer Belastung zu gewährleisten.

Abstract

Background: An overview of prospective studies on cementless and cemented primary knee joint endoprosthetics carried out between 1988 and 2004 reveals that the aseptic tibial loosening rate of cemented prostheses implanted with fixed meniscal bearings amounts to 2–6% within a period of 4–14 years, while cementless implanted prostheses show loosening rates of up to 28% within a period of 4–10 years. If these results arise from a lack of proper initial osseointegration as a result of insufficient primary stability, and how this is influenced by the tibial bone quality and the tibial fixation procedure has not yet been investigated.

Materials and methods: Tibial plateaus were press-fit implanted, both screwed and unscrewed, into each of six pairs of tibial heads from corpses. Stability testing was conducted applying eccentric axial load, shear and torsion.

Results: The average amounts of relative movement at the medial and lateral plateau are clearly different in the screwed version and the unscrewed version when loaded axially, but the difference was significant (p=0.016) only at the medial plateau. Relative movements under shear and torsion showed no significant differences. The bone density of the tibial metaphyses had no significant effect on the primary stability of the cementless implanted tibial plateau.

Conclusion: When using cementless knee endoprostheses, the fixation of the tibial plateau with screws – in addition to a flawless press-fit and form-fit customization of the tibial head – appears indispensable for guaranteeing proper osseointegration under physiological axial loads.


Korrespondenz: Dr. med. Carsten Boos, Klinik für Orthopädie, Universitätsklinikum Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck, Deutschland Phone: +49-(0)451-500 2301 Fax: +49-(0)451-500 3333

Erhalten: 2007-3-25
Angenommen: 2008-1-7
Online erschienen: 2008-04-16
Erschienen im Druck: 2008-04-01

©2008 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Research articles
  2. Experimentelle Untersuchung zu einem neuen Verfahren für den koloskopischen Verschluss von Dickdarmperforationen mit dem OTSC®-Clip / Experimental study on a new method for colonoscopic closure of large-bowel perforations with the OTSC® clip
  3. Inverse finite element characterization of the human myometrium derived from uniaxial compression experiments / Von einaxialen Druckversuchen hergeleitete inverse Finite-Elemente-Charakterisierung des menschlichen Myometriums
  4. A simple measuring device for laboratory indentation tests on cartilage / Eine einfache Prüfvorrichtung für Indentationsversuche am Knorpel
  5. A rapid prototyping model for biomechanical evaluation of pelvic osteotomies / Ein Modell zur biomechanischen Bewertung von Beckenosteotomien
  6. Der Einfluss der Knochenmineraldichte und des Verankerungsverfahrens auf die Primärstabilität von zementfrei implantierten Tibiakomponenten / The influence of bone quality and the fixation procedure on the primary stability of cementless implanted tibial plateaus
  7. Biomechanische Analysen zur Verbundfestigkeit eines bioresorbierbaren Knochenklebers: experimentelle Untersuchungen am Schafsmodell / Bond strength of a bioresorbable bone adhesive: results of a biomechanical study in a sheep model
  8. Dynamische Analyse von Osteosynthesen am Olecranon: ein in-vitro Vergleich zweier Osteosynthesesysteme / Dynamic analysis of olecranon osteosyntheses – an in vitro comparison of two osteosynthesis systems
  9. Book review
  10. Science and technology in medicine: an illustrated account based on ninety-nine landmark publications from five centuries
Downloaded on 24.2.2026 from https://www.degruyterbrill.com/document/doi/10.1515/BMT.2008.013/html