Abstract
In this paper an intelligent-based approach is introduced to evaluate harmonic overvoltages during three-phase transformer energization. In a power system that appears in an early stage of a black start of a power system, an overvoltage could be caused by core saturation on the energization of a three-phase transformer with residual flux. Such an overvoltage might damage some equipment and delay power system restoration. A new approach based on worst case determination is proposed to reduce time-domain simulations. Also, an artificial neural network (ANN) has been used to estimate the temporary overvoltages (TOVs) due to three-phase transformer energization. Three learning algorithms, delta-bar-delta (DBD), extended delta-bar-delta (EDBD), and directed random search (DRS), were used to train the ANNs. ANN Training is performed based on equivalent circuit parameters of the network; thus trained ANN is applicable to every studied system. The developed ANN is trained with the worst case of the switching condition and remanent flux, and tested for typical cases. The simulated results for a partial of 39-bus New England test system, show that the proposed technique can estimate the peak values and durations of switching overvoltages with good accuracy and EDBD algorithm presents best performance.
©2012 Walter de Gruyter GmbH & Co. KG, Berlin/Boston
Articles in the same Issue
- Article
- ANN - SQP Approach For NOx Emission Reduction In Coal Fired Boilers
- Comparison of Levenberg-Marquardt Method and Path Following Interior Point Method for the Solution of Optimal Power Flow Problem
- A Transient Stability Constrained, Line-Flow-Based Fast Contingency Screening and Power Flow Evaluation
- Study of Transformer Switching Overvoltages during Power System Restoration Using Delta-Bar-Delta and Directed Random Search Algorithms
- Economic Justification for a V2G Facility in a Radial Distribution Network
- Operation of Multi DC Smart Grids Based on Renewable Energy Sources and Protection of DC Transmission Line
- Novel Real-Time Stability Assessment Algorithm Based on Synchro-Phasors Measurement and Parallel Algorithms for Multi-Machine Networks.
- Integrated Kalman-Independent Component Analysis Method for Harmonic Current Estimation on an Interconnected Four Bus Simulated and Laboratory Model
- Identification of Fault Location in Distribution Networks Using Multi Class Support Vector Machines
Articles in the same Issue
- Article
- ANN - SQP Approach For NOx Emission Reduction In Coal Fired Boilers
- Comparison of Levenberg-Marquardt Method and Path Following Interior Point Method for the Solution of Optimal Power Flow Problem
- A Transient Stability Constrained, Line-Flow-Based Fast Contingency Screening and Power Flow Evaluation
- Study of Transformer Switching Overvoltages during Power System Restoration Using Delta-Bar-Delta and Directed Random Search Algorithms
- Economic Justification for a V2G Facility in a Radial Distribution Network
- Operation of Multi DC Smart Grids Based on Renewable Energy Sources and Protection of DC Transmission Line
- Novel Real-Time Stability Assessment Algorithm Based on Synchro-Phasors Measurement and Parallel Algorithms for Multi-Machine Networks.
- Integrated Kalman-Independent Component Analysis Method for Harmonic Current Estimation on an Interconnected Four Bus Simulated and Laboratory Model
- Identification of Fault Location in Distribution Networks Using Multi Class Support Vector Machines