Abstract
Background: Adiponectin, present in different multimeric forms in circulation, is increasingly used in clinical settings as a cardiometabolic marker. The development of several commercially available enzyme-linked immunosorbent assays (ELISA) has allowed for the widespread measurement of adiponectin in research as well as in clinical practice. The comparative performance of these assays is thus an issue of major relevance.
Methods: The analytical performance of four different ELISAs (LINCO, B-Bridge, SPIbio and ALPCO) was evaluated. Samples from 102 cardiac patients and 40 healthy subjects were tested using LINCO and ALPCO. The latter is able to measure the concentrations of multimers. For the multimer assay, an error propagation study was performed. A subset of subjects was tested by all four ELISAs for comparison purposes.
Results: Bland-Altman plots revealed differences between the results of the four ELISAs, mainly for ALPCO. However, a strong correlation between the different ELISAs (ALPCO, r=0.83; B-Bridge, r=0.98; SPIbio, r=0.91 vs. LINCO) was observed. Total adiponectin measured by LINCO showed a better association with cardiac disease [receiver-operating characteristic (ROC) curves] than total and high molecular weight adiponectin measured by ALPCO.
Conclusions: The results of this study contribute to a better understanding of the methodological features of the several ELISAs, and help in the evaluation and comparison of the relative results.
Clin Chem Lab Med 2010;48:561–8.
©2010 by Walter de Gruyter Berlin New York
Articles in the same Issue
- Editorials
- Molecular biology and genetics in clinical chemistry and laboratory medicine
- Improving the post-analytical phase
- Reviews
- State of the art in therapeutic drug monitoring
- Decision criteria for rational selection of homogeneous genotyping platforms for pharmacogenomics testing in clinical diagnostics
- Reference Values and Biological Variations
- Assessment of critical values policies in Italian institutions: comparison with the US situation
- Genetics and Molecular Diagnostics
- Performance evaluation of the Abbott RealTime HCV Genotype II for hepatitis C virus genotyping
- Genotyping mitochondrial DNA single nucleotide polymorphisms by PCR ligase detection reactions
- FOXL2 mutations in Taiwanese patients with blepharophimosis, ptosis, epicanthus inversus syndrome
- Low expression of human β-defensin 1 in duodenum of celiac patients is partially restored by a gluten-free diet
- General Clinical Chemistry and Laboratory Medicine
- Evaluation of C-reactive protein and serum amyloid A in the detection of inflammatory and infectious diseases in children
- Procalcitonin measurement in routine emergency medicine practice: comparison between two immunoassays
- Clinical application of a lectin-antibody ELISA to measure fucosylated haptoglobin in sera of patients with pancreatic cancer
- Simultaneous determination of serum tryptophan metabolites in patients with systemic lupus erythematosus by high performance liquid chromatography with fluorescence detection
- Beware of carryover in modern chemistry analyzers
- Correlation between glucose and bupivacaine levels in cerebrospinal fluid after spinal anesthesia: glycorrhachia as predictor for duration of sensory block
- Comparison of different depletion strategies for improving resolution of the human urine proteome
- Cardiovascular Diseases
- Pregnancy-associated plasma protein-A as a marker for long-term mortality in patients with peripheral atherosclerosis: inconclusive findings from the Linz Peripheral Arterial Disease (LIPAD) study
- Association of matrix metalloproteinase 9 genotypes and cardiovascular disease risk factors with serum matrix metalloproteinase 9 concentrations in Taiwanese individuals
- C-reactive protein variants are not associated with susceptibility to stroke and stroke recurrence
- Association of hyperhomocysteinemia with left ventricular dilatation and mass in human heart
- A methodological reappraisal of total and high molecular weight adiponectin determination in human peripheral circulation: comparison of four immunometric assays
- Letters to the Editor
- High specificity but low sensitivity of the cartilage oligomeric matrix protein (COMP) test in rheumatoid arthritis and osteoarthritis
- Disparity in estimated average glucose due to different hemoglobin A1c methods and hemoglobin S trait
Articles in the same Issue
- Editorials
- Molecular biology and genetics in clinical chemistry and laboratory medicine
- Improving the post-analytical phase
- Reviews
- State of the art in therapeutic drug monitoring
- Decision criteria for rational selection of homogeneous genotyping platforms for pharmacogenomics testing in clinical diagnostics
- Reference Values and Biological Variations
- Assessment of critical values policies in Italian institutions: comparison with the US situation
- Genetics and Molecular Diagnostics
- Performance evaluation of the Abbott RealTime HCV Genotype II for hepatitis C virus genotyping
- Genotyping mitochondrial DNA single nucleotide polymorphisms by PCR ligase detection reactions
- FOXL2 mutations in Taiwanese patients with blepharophimosis, ptosis, epicanthus inversus syndrome
- Low expression of human β-defensin 1 in duodenum of celiac patients is partially restored by a gluten-free diet
- General Clinical Chemistry and Laboratory Medicine
- Evaluation of C-reactive protein and serum amyloid A in the detection of inflammatory and infectious diseases in children
- Procalcitonin measurement in routine emergency medicine practice: comparison between two immunoassays
- Clinical application of a lectin-antibody ELISA to measure fucosylated haptoglobin in sera of patients with pancreatic cancer
- Simultaneous determination of serum tryptophan metabolites in patients with systemic lupus erythematosus by high performance liquid chromatography with fluorescence detection
- Beware of carryover in modern chemistry analyzers
- Correlation between glucose and bupivacaine levels in cerebrospinal fluid after spinal anesthesia: glycorrhachia as predictor for duration of sensory block
- Comparison of different depletion strategies for improving resolution of the human urine proteome
- Cardiovascular Diseases
- Pregnancy-associated plasma protein-A as a marker for long-term mortality in patients with peripheral atherosclerosis: inconclusive findings from the Linz Peripheral Arterial Disease (LIPAD) study
- Association of matrix metalloproteinase 9 genotypes and cardiovascular disease risk factors with serum matrix metalloproteinase 9 concentrations in Taiwanese individuals
- C-reactive protein variants are not associated with susceptibility to stroke and stroke recurrence
- Association of hyperhomocysteinemia with left ventricular dilatation and mass in human heart
- A methodological reappraisal of total and high molecular weight adiponectin determination in human peripheral circulation: comparison of four immunometric assays
- Letters to the Editor
- High specificity but low sensitivity of the cartilage oligomeric matrix protein (COMP) test in rheumatoid arthritis and osteoarthritis
- Disparity in estimated average glucose due to different hemoglobin A1c methods and hemoglobin S trait