Home Examiner’s finger-mounted fetal tissue oximetry: a preliminary report on 30 cases
Article
Licensed
Unlicensed Requires Authentication

Examiner’s finger-mounted fetal tissue oximetry: a preliminary report on 30 cases

  • Toshiyuki Uchida , Naohiro Kanayama EMAIL logo , Mari Mukai , Naomi Furuta , Hiroaki Itoh , Hikaru Suzuki and Masatsugu Niwayama
Published/Copyright: March 9, 2015

Abstract

Objective:

To describe preliminary experience with a finger-mounted fetal tissue oximetry probe during the 2nd stage of labor.

Materials and methods:

A total of 30 term pregnant women without pregnancy complications were recruited. We measured fetal tissue oxygen saturation (FtO2) by using a finger-mounted fetal tissue oximetry during cervical examinations in the 2nd stage of labor. The data capturing rate of FtO2 and the interclass correlation coefficient were also examined. The mean FtO2 was compared to the neonatal condition assessed by the levels of umbilical cord blood.

Results:

FtO2 was obtained in all cases, regardless of wetness, hair color, the part of the fetal head that was exposed, rotation of the fetus, color of amniotic fluid, and caput succedaneum. The mean FtO2 was 65.5%±8.58% in normal neonates [Apgar score >7 (1 min), n=25]. The mean FtO2 was significantly correlated with umbilical cord arterial pH (r=0.52, P=0.0030, n=30), but not with umbilical cord arterial partial pressure of oxygen. The interclass correlation coefficient was 0.94.

Conclusions:

Tissue oxygen saturation of the fetal head was obtained easily by the examiner’s finger-mounted fetal tissue oximetry.


Corresponding author: Naohiro Kanayama, MD, PhD, Department of Obstetrics and Gynecology, Hamamatsu University School of Medicine, 1-20-1 Handa-yama, Hamamatsu 431-3192, Japan, Tel.: +81-453-435-2309, Fax: +81-453-435-2308, E-mail:

Acknowledgments

We would like to thank Mr. Yutaka Yokoyama and Yukio Chitose of ASTEM Co., Ltd., Kawasaki, Japan for advice in the development of the instruments. We acknowledge the financial support of the Adaptable and Seamless Technology transfer Program through target driven R&D (A-STEP) program from the Japan Science and Technology Agency (JST).

References

[1] Signore C, Freeman RK, Spong CY. Antenatal testing – a reevaluation: executive summary of a Eunice Kennedy Shriver National Institute of Child Health and Human Development workshop. Obstet Gynecol. 2009;113:687–701.10.1097/AOG.0b013e318197bd8aSearch in Google Scholar

[2] Langer B, Carbonne B, Goffinet F, Le Gouëff F, Berkane N, Laville M. Fetal pulse oximetry and fetal heart rate monitoring during stage II of labour. Eur J Obstet Gynecol Reprod Biol. 1997;72:S57–61.10.1016/S0301-2115(97)02719-XSearch in Google Scholar

[3] Arikan GM, Haeusler MC, Deutsch MT, Greimel ER, Dorfer M. Maternal perceptions of labor with fetal monitoring by pulse oximetry in a research setting. Birth. 1998;25:182–9.10.1046/j.1523-536X.1998.00182.xSearch in Google Scholar

[4] Garite TJ, Dildy GA, McNamara H, Nageotte MP, Boehm FH, Dellinger EH, et al. A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns. Am J Obstet Gynecol. 2000;183:1049–58.10.1067/mob.2000.110632Search in Google Scholar

[5] Colditz PB, Begg L, East CE. Fetal pulse oximetry. Instrumentation and recent clinical experience. Clin Perinatol. 1999;26:869–80.10.1016/S0095-5108(18)30024-1Search in Google Scholar

[6] Knitza R, Rall G, Schaller N, Kolben M. First results of a pilot study with the FetalSAT fetal pulse oximetry system. Geburtshilfe Frauenheilkd. 2004;64:600–5.10.1055/s-2004-820896Search in Google Scholar

[7] East CE, Begg L, Colditz PB, Lau R. Fetal pulse oximetry for fetal assessment in labour. Cochrane Database Syst Rev. 2014;10:CD004075.10.1002/14651858.CD004075.pub4Search in Google Scholar

[8] van Oudgaarden E, Johnson N. Clinical value of antenatal fetal pulse oximetry. J Perinat Med. 1994;22:295–300.10.1515/jpme.1994.22.4.295Search in Google Scholar

[9] Dildy GA, van den Berg PP, Katz M, Clark SL, Jongsma HW, Nijhuis JG, et al. Intrapartum fetal pulse oximetry: fetal oxygen saturation trends during labor and relation to delivery outcome. Am J Obstet Gynecol. 1994;171:679–84.10.1016/0002-9378(94)90081-7Search in Google Scholar

[10] Dildy GA. Fetal pulse oximetry. Clin Obstet Gynecol. 2011;54:66–73.10.1097/GRF.0b013e31820a0f71Search in Google Scholar PubMed

[11] Aldrich CJ, D’Antona D, Wyatt JS, Spencer JA, Peebles DM, Reynolds EO. Fetal cerebral oxygenation measured by near-infrared spectroscopy shortly before birth and acid-base status at birth. Obstet Gynecol. 1994;84:861–6.Search in Google Scholar

[12] Schmidt S. Laserspectroscopy in the fetus during labour. Eur J Obstet Gynecol Reprod Biol. 2003;110:S127–31.10.1016/S0301-2115(03)00183-0Search in Google Scholar

[13] East CE. Chan FY, Colditz P.B, Begg LM. Fetal pulse oximetry for fetal assessment in labour. Cochrane Database Syst Rev. 2007;2:CD004075.10.1002/14651858.CD004075.pub3Search in Google Scholar PubMed

[14] Kanayama N, Niwayama M. Examiner’s finger-mounted fetal tissue oximetry. J Biomed Opt. 2014;19:1–5.10.1117/1.JBO.19.6.067008Search in Google Scholar PubMed

[15] Amano K, Hirano S, Nishijima M. Significance of fetal arterial oxygen saturation (SpO2) monitoring. Nihon Sanka Fujinka Gakkai Zasshi. 1996;48:96–102.Search in Google Scholar

[16] Pichler G, Binder C, Avian A, Beckenbach E, Schmolzer GM, Urlesberger B. Reference ranges for regional cerebral tissue oxygen saturation and fractional oxygen extraction in neonates during immediate transition after birth. J Pediatr. 2013;163:1558–63.10.1016/j.jpeds.2013.07.007Search in Google Scholar PubMed

[17] Fouzas S, Priftis KN, Anthoracopoulos MB. Pulse oximetry in pediatric practice. Pediatrics. 2011;128:740–52.10.1542/peds.2011-0271Search in Google Scholar PubMed

  1. The authors stated that there are no conflicts of interest regarding the publication of this article.

Received: 2014-9-4
Accepted: 2015-2-10
Published Online: 2015-3-9
Published in Print: 2016-10-1

©2016 Walter de Gruyter GmbH, Berlin/Boston

Articles in the same Issue

  1. Frontmatter
  2. Editorials
  3. Editorial
  4. First 10 years of the International Academy of Perinatal Medicine – which lessons we have learned and what are future challenges
  5. Recommendation and Guidelines for Perinatal Practice
  6. Is intrauterine surgery justified? Report from the working group on ultrasound in obstetrics of the World Association of Perinatal Medicine (WAPM)
  7. Original articles - Obstetrics
  8. Examiner’s finger-mounted fetal tissue oximetry: a preliminary report on 30 cases
  9. Values of T/QRS ratio in pregnancies complicated by intrauterine growth restriction
  10. Cesarean delivery among women with prolonged labor induction
  11. Maternal and fetal outcomes after uterine fundal pressure in spontaneous and assisted vaginal deliveries
  12. Impact of maternal age on delivery outcomes following spontaneous labour at term
  13. Maternal characteristics of pregnancies with intrauterine fetal demise
  14. Evaluation of standardized, computerized Dawes/Redman heart-rate analysis based on different recording methods and in relation to fetal beat-to-beat heart rate variability
  15. Perinatal outcomes with isolated oligohydramnios at term pregnancy
  16. Factors associated with choice of delivery with or without epidural analgesia among laboring women: a cross-sectional survey at a tertiary care hospital of a developing country
  17. Ultrasonographic assessment of cervical length in pregnancies scheduled for a cesarean delivery: prediction of early spontaneous onset of labor
  18. Characterization of visceral and subcutaneous adipose tissue transcriptome in pregnant women with and without spontaneous labor at term: implication of alternative splicing in the metabolic adaptations of adipose tissue to parturition
  19. Classification of stillbirths is an ongoing dilemma
  20. Out-of-hospital births in the United States 2009–2014
  21. Congress Calendar
  22. Congress Calendar
Downloaded on 21.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/jpm-2014-0297/html
Scroll to top button