Abstract
This article presents applications of the excitation function on the prediction of the radio interference (RI) of overhead transmission line (OHTL), due to corona effect. These applications are done under different weather conditions such as heavy rain, wet conductor, and fair weather.Also, this article investigates the factors influencing the RI level, namely, the height of conductors, phase spacing, number of subconductors in the bundle, diameter of subconductor, and subconductor spacing in the bundle.In this article, it is shown that the RI level is dependent on the weather conditions. Where the RI level under heavy rain has the maximum level, hence, it should be considered as a basic level of any OHTL.
References
1. Suljanovic N, Mujcic A, Zajc M, Tasic, J.F. Computation of high-frequency and time characteristics of corona noise on HV power line. IEEE Trans Power Deliv 2005;20:71–9.10.1109/TPWRD.2004.838656Search in Google Scholar
2. Zajc M, Suljanovic N, Mujcic A, Tasic, J.F. Frequency characteristics measurement of overhead high-voltage power-line in low radio-frequency range. IEEE Trans Power Deliv 2007;22:2142–9.10.1109/TPWRD.2007.905369Search in Google Scholar
3. Moreau MR, Gary CH. Predetermination of the radio-interference level of high voltage transmission lines: II-field calculating method. IEEE Trans Power Apparat Syst 1972;PAS-91:291–304.10.1109/TPAS.1972.293363Search in Google Scholar
4. Moreau MR, Gary CH. Predetermination of the radio-interference level of high voltage transmission lines: I – predetermination of the excitation function. IEEE Trans Power Apparat Syst 1972;PAS-91:284–91.10.1109/TPAS.1972.293362Search in Google Scholar
5. Olsen RG, Schennum SD. A method for calculating wide-band electromagnetic-interference from power-line corona. IEEE Trans Power Deliv 1995;10:1535–40.10.1109/61.400938Search in Google Scholar
6. Tejada C, Gómez P, Escamilla JC. Computation of radio interference levels in high voltage transmission lines with corona. IEEE Lat Am Trans 2009;7:54–61.10.1109/TLA.2009.5173465Search in Google Scholar
7. International Electrotechnical Commission. Radio interference characteristics of overhead power lines and high-voltage equipment, part 1: description of phenomena. C.I.S.P.R. Publication 18–1, 1982.Search in Google Scholar
8. Anderson JG. Transmission line reference book 345 kV and above. Palo Alto, CA: Electric Power Research Institute, 1975.Search in Google Scholar
9. Urban RG, Reader HC, Holtzhausen JP. Small corona cage for wideband HVac radio noise studies: rationale and critical design. IEEE Trans Power Deliv 2008;23:1150–7.10.1109/TPWRD.2008.915806Search in Google Scholar
10. Begamudre RD. Extra high voltage AC. Transmission engineering, 3rd ed. Hoboken, NJ: Wiley, 2006, ch. 7:172–205.Search in Google Scholar
11. Grigsby LL. The electric power engineering handbook, third edition, “Part III: transmission system”, Georgy G. Karady. Boca Raton, FL: CRC Press, 2012.Search in Google Scholar
12. Juette GW. Comparison of radio noise prediction methods with CIGRE/IEEE survey results. IEEE Trans Power Apparat Syst 1973;PAS-92:1029–42.10.1109/TPAS.1973.293669Search in Google Scholar
©2013 by Walter de Gruyter Berlin / Boston
Articles in the same Issue
- Masthead
- Masthead
- An Investigation into the Physico-chemical Properties of Transformer Oil Blends with Antioxidants extracted from Turmeric Powder
- Prediction of Egyptian 500-kV Overhead Transmission Line’s Radio Interference by Using the Excitation Function
- LCL Filter with Active Damping using PI and SSI Regulators in Synchronous Rotating Reference Frame Current Controller for DSTATCOM
- Review
- A Comprehensive Overview of Different Protection Schemes in Micro-Grids
- DC–DC Type High-Frequency Link DC for Improved Power Quality of Cascaded Multilevel Inverter
- An Empirical Study of Synchrophasor Communication Delay in a Utility TCP/IP Network
- Power Management Based Current Control Technique for Photovoltaic-Battery Assisted Wind–Hydro Hybrid System
- Development of Wave Turbine Emulator in a Laboratory Environment
- Erratum
- Online Assessment of Voltage Stability in Power Systems with PMUs
Articles in the same Issue
- Masthead
- Masthead
- An Investigation into the Physico-chemical Properties of Transformer Oil Blends with Antioxidants extracted from Turmeric Powder
- Prediction of Egyptian 500-kV Overhead Transmission Line’s Radio Interference by Using the Excitation Function
- LCL Filter with Active Damping using PI and SSI Regulators in Synchronous Rotating Reference Frame Current Controller for DSTATCOM
- Review
- A Comprehensive Overview of Different Protection Schemes in Micro-Grids
- DC–DC Type High-Frequency Link DC for Improved Power Quality of Cascaded Multilevel Inverter
- An Empirical Study of Synchrophasor Communication Delay in a Utility TCP/IP Network
- Power Management Based Current Control Technique for Photovoltaic-Battery Assisted Wind–Hydro Hybrid System
- Development of Wave Turbine Emulator in a Laboratory Environment
- Erratum
- Online Assessment of Voltage Stability in Power Systems with PMUs