No evidence for an association between the rs2824292 variant at chromosome 21q21 and ventricular fibrillation during acute myocardial infarction in a German population
-
Peter Bugert
, Elif Elmas, Ksenija Stach
, Christel Weiss , Thorsten Kälsch , Dobromir Dobrev and Martin Borggrefe
Abstract
Background: In a recently published genome-wide association study (GWAS), three single nucleotide polymorphisms (SNPs) (rs2824292, rs1353342, rs12090554) were significantly associated with increased susceptibility for ventricular fibrillation (VF) during acute myocardial infarction (AMI). The association of rs2824292 could be confirmed in a second cohort. Both cohorts were from the Netherlands. We aimed to replicate this association in a German cohort of AMI patients with or without VF.
Methods: We included a German cohort of 90 individuals with AMI and VF (cases) and 167 AMI individuals without VF and used Taqman assays for SNP typing.
Results: None of the loci showed evidence for a statistically significant association with VF. The observed genotype frequencies of the three loci were in Hardy-Weinberg equilibrium, which essentially excludes genotyping errors.
Conclusions: In contrast to the data from the Netherlands, we could not detect a significant association of the rs2824292 locus and risk of VF during AMI in our German cohort. Differences in recruitment and clinical phenotypes between the Dutch and German cohorts may underlie different genotype associations.
©2011 by Walter de Gruyter Berlin Boston
Articles in the same Issue
- Editorial
- Method comparison: where do we draw the line?
- Review
- Current role of liquid chromatography coupled to mass spectrometry in clinical toxicology screening methods
- Minireview
- Molecular diagnostics for pharmacogenomic testing of fluoropyrimidine based-therapy: costs, methods and applications
- Opinion Paper
- Preanalytical quality improvement: from dream to reality
- Point
- Towards more complete specifications for acceptable analytical performance – a plea for error grid analysis
- Counterpoint
- Closing the brain-to-brain loop in laboratory testing
- General Clinical Chemistry and Laboratory Medicine
- Harmonization of growth hormone measurements with different immunoassays by data adjustment
- Comparison of the results from two different External Quality Assessment Schemes supports the utility of robust quality specifications
- High-throughput LC-MS/MS method for monitoring sirolimus and everolimus in the routine clinical laboratory
- Performance of the Roche Total Mycophenolic Acid® assay on the Cobas Integra 400®, Cobas 6000® and comparison to LC-MS/MS in liver transplant patients
- Diagnostic efficiency of truncated area under the curve from 0 to 2 h (AUC0–2) of mycophenolic acid in kidney transplant recipients receiving mycophenolate mofetil and concomitant tacrolimus
- Good performance of an immunoassay based method for nevirapine measurements in human breast milk
- Measurement of plasma amino acids by Ultraperformance® Liquid Chromatography
- Interchangeability of blood gas, electrolyte and metabolite results measured with point-of-care, blood gas and core laboratory analyzers
- Granularity Index of the SYSMEX XE-5000 hematology analyzer as a replacement for manual microscopy of toxic granulation neutrophils in patients with inflammatory diseases
- Direct chromogenic substrate immuno-capture activity assay for testing of factor VII-activating protease
- The antinuclear antibody assay: developing criteria for reflexive anti-dsDNA antibody testing in a laboratory setting
- A simple liquid chromatography-tandem mass spectrometry method for measuring metanephrine and normetanephrine in urine
- Monoclonal gammopathy missed by capillary zone electrophoresis
- Adaptation of the Diazyme Direct Enzymatic HbA1c Assay for a microplate reader at room temperature
- Validation and Outcome Studies
- Laboratory assessment of iron status in pregnancy
- Cardiovascular Diseases
- Blood cells characteristics as determinants of acute myocardial infarction
- No evidence for an association between the rs2824292 variant at chromosome 21q21 and ventricular fibrillation during acute myocardial infarction in a German population
- Letters to the Editor
- Letter to the Editor Reply: Statistical methods for assessment of added usefulness of new biomarkers
- Reply to Vavrova et al. Clin Chem Lab Med 2011;49:89–92
Articles in the same Issue
- Editorial
- Method comparison: where do we draw the line?
- Review
- Current role of liquid chromatography coupled to mass spectrometry in clinical toxicology screening methods
- Minireview
- Molecular diagnostics for pharmacogenomic testing of fluoropyrimidine based-therapy: costs, methods and applications
- Opinion Paper
- Preanalytical quality improvement: from dream to reality
- Point
- Towards more complete specifications for acceptable analytical performance – a plea for error grid analysis
- Counterpoint
- Closing the brain-to-brain loop in laboratory testing
- General Clinical Chemistry and Laboratory Medicine
- Harmonization of growth hormone measurements with different immunoassays by data adjustment
- Comparison of the results from two different External Quality Assessment Schemes supports the utility of robust quality specifications
- High-throughput LC-MS/MS method for monitoring sirolimus and everolimus in the routine clinical laboratory
- Performance of the Roche Total Mycophenolic Acid® assay on the Cobas Integra 400®, Cobas 6000® and comparison to LC-MS/MS in liver transplant patients
- Diagnostic efficiency of truncated area under the curve from 0 to 2 h (AUC0–2) of mycophenolic acid in kidney transplant recipients receiving mycophenolate mofetil and concomitant tacrolimus
- Good performance of an immunoassay based method for nevirapine measurements in human breast milk
- Measurement of plasma amino acids by Ultraperformance® Liquid Chromatography
- Interchangeability of blood gas, electrolyte and metabolite results measured with point-of-care, blood gas and core laboratory analyzers
- Granularity Index of the SYSMEX XE-5000 hematology analyzer as a replacement for manual microscopy of toxic granulation neutrophils in patients with inflammatory diseases
- Direct chromogenic substrate immuno-capture activity assay for testing of factor VII-activating protease
- The antinuclear antibody assay: developing criteria for reflexive anti-dsDNA antibody testing in a laboratory setting
- A simple liquid chromatography-tandem mass spectrometry method for measuring metanephrine and normetanephrine in urine
- Monoclonal gammopathy missed by capillary zone electrophoresis
- Adaptation of the Diazyme Direct Enzymatic HbA1c Assay for a microplate reader at room temperature
- Validation and Outcome Studies
- Laboratory assessment of iron status in pregnancy
- Cardiovascular Diseases
- Blood cells characteristics as determinants of acute myocardial infarction
- No evidence for an association between the rs2824292 variant at chromosome 21q21 and ventricular fibrillation during acute myocardial infarction in a German population
- Letters to the Editor
- Letter to the Editor Reply: Statistical methods for assessment of added usefulness of new biomarkers
- Reply to Vavrova et al. Clin Chem Lab Med 2011;49:89–92