Abstract

Background: The use of heparin as an alternative to EDTA in the production of plasma samples is of particular interest for B-type natriuretic peptide (BNP) measurements. Lithium heparin is now widely used for the determination of biochemical parameters, including cardiac markers. The goal of this study was to determine the feasibility of measuring BNP using heparin plasma instead of EDTA plasma with the Access 2 system (Beckman-Coulter).

Methods: BNP was determined in heparin plasma and EDTA plasma from 24 patients within 1 h of blood collection. Additional measurements were performed with heparin plasma, every hour for the first 4 h, and then 8 h after the collection of blood that was stored at room temperature.

Results: At H0, the observed BNP concentrations in heparin plasma were much higher (mean values 65% higher) than those in EDTA plasma. Using predetermined thresholds, this difference would lead to 30% discordance between samples in heparin and EDTA. BNP stability decreased over time in heparin plasma: immunoreactivity decreased approximately by 30% during the first 2 h and by 60% after 8 h.

Conclusions: Heparin plasma does not seem to be a suitable alternative to EDTA plasma for measurement of BNP using the Access 2 system, even if measurements are performed immediately after blood sampling.

Clin Chem Lab Med 2010;48:399–401.


Corresponding author: Dr. Bruno Cauliez, Laboratoire de Biochimie Médicale, CHU de Rouen-Hôpital Charles Nicolle, 76031 Rouen-Cedex, France Phone: +33 232888135,

Received: 2009-7-31
Accepted: 2009-10-23
Published Online: 2010-02-1
Published in Print: 2010-03-01

©2010 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Editorial
  2. Standardization of assays for clinically important enzymes that have high biologic variation: what is all the fuss about?
  3. Minireview
  4. Standardization in clinical enzymology: a challenge for the theory of metrological traceability
  5. Review
  6. Laboratory reporting of hemostasis assays: the final post-analytical opportunity to reduce errors of clinical diagnosis in hemostasis?
  7. Opinion Paper
  8. The underestimated problem of using serum magnesium measurements to exclude magnesium deficiency in adults; a health warning is needed for “normal” results
  9. Genetics and Molecular Diagnostics
  10. Integrated PCR amplification and detection processes on a Lab-on-Chip platform: a new advanced solution for molecular diagnostics
  11. Matrix metalloproteinase-7 (MMP-7) polymorphism is a risk factor for endometrial cancer susceptibility
  12. Association of the CD28/CTLA4/ICOS polymorphisms with susceptibility to rheumatoid arthritis
  13. Lack of association between DAZ gene methylation patterns and spermatogenic failure
  14. General Clinical Chemistry and Laboratory Medicine
  15. Evaluation of five routine glucose methods on an Olympus AU5400 analyzer using the CDC hexokinase reference method
  16. Multicentre evaluation of the Tosoh HbA1c G8 analyser
  17. Performance of a fully automated quantitative neopterin measurement assay in a routine voluntary blood donation setting
  18. Assay of oxidized fibrinogen reactivity (OFR) as a biomarker of oxidative stress in human plasma: the role of lysine analogs
  19. Decrease in uric acid in acute ischemic stroke correlates with stroke severity, evolution and outcome
  20. Development and validation of a high performance liquid chromatography method to determine linezolid concentrations in pig pulmonary tissue
  21. Is heparin plasma suitable for the determination of B-type natriuretic peptide on the Beckman-Coulter Access 2?
  22. Composition of kidney stone fragments obtained after extracorporeal shock wave lithotripsy
  23. Reference Values and Biological Variations
  24. Gender does not influence cystatin C concentrations in healthy volunteers
  25. Stability of serum thyroid hormones following 8–11 years of cold storage
  26. Infectious Diseases
  27. Detection and quantitation of Epstein-Barr virus (EBV) DNA in EDTA whole blood samples using automated sample preparation and real time PCR
  28. Letters to the Editor
  29. The polymorphisms –1131T>C and the S19W of the APOA5 gene are not associated with coronary artery disease in a Brazilian population
  30. Tissue factor +5466A>G and –1208D>I genetic polymorphisms and severity of rheumatoid arthritis
  31. Ability of deferasirox to bind iron during measurement of iron
Downloaded on 6.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2010.069/pdf
Scroll to top button