Home Laboratory reference intervals during pregnancy, delivery and the early postpartum period
Article
Licensed
Unlicensed Requires Authentication

Laboratory reference intervals during pregnancy, delivery and the early postpartum period

  • Anna Klajnbard , Pal B. Szecsi , Nina P. Colov , Malene R. Andersen , Maja Jørgensen , Brian Bjørngaard , Anne Barfoed , Katrine Haahr and Steen Stender
Published/Copyright: November 30, 2009

Abstract

Background: Physiological changes during pregnancy may affect laboratory parameters. Reference values based on samples from non-pregnant women are not necessarily useful for clinical decisions during pregnancy. There is a need to establish reference values during pregnancy in order to recognize pathological conditions.

Methods: Eight hundred and one women with expected normal pregnancies were included in the study. Of these, 391 had no complications during pregnancy, delivery, or the early postpartum period. Blood samples were obtained at gestational weeks 13–20, 21–28, 29–34, 35–42, at labor, and 1 and 2 days postpartum. Reference intervals were calculated for 36 tests as recommended by the International Federation of Clinical Chemistry and Laboratory Medicine.

Results: Many tests showed such large variations indicating that gestational age-specific reference intervals were necessary. Other tests had different but stable values when compared to non-pregnant women. A minor decrease in albumin levels was observed. This was not only due to pregnancy-associated hemodilution, since other components with the same or a larger molecular diameter did not show a similar decrease. Many tests exhibited a broad distribution around vaginal delivery and in the early postpartum period.

Conclusions: Only a few parameters were unaffected during uncomplicated pregnancy, delivery, and the early postpartum period suggesting that implementation of gestational age-specific reference intervals is necessary.

Clin Chem Lab Med 2010;48:237–48.


Corresponding author: Pal B. Szecsi, Department of Clinical Biochemistry, Gentofte Hospital, University of Copenhagen, Niels Andersens Vej 65, 2900 Hellerup, Denmark Phone: +45 3977 7494, Fax: +45 3997 8193,

Received: 2009-6-9
Accepted: 2009-9-23
Published Online: 2009-11-30
Published in Print: 2010-02-01

©2010 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Review
  2. Elevated serum γ-glutamyltransferase activity is associated with increased risk of mortality, incident type 2 diabetes, cardiovascular events, chronic kidney disease and cancer – a narrative review
  3. Minireview
  4. Artificial intelligence for diagnostic purposes: principles, procedures and limitations
  5. General Clinical Chemistry and Laboratory Medicine
  6. Association between serum alkaline phosphatase and C-reactive protein in the United States National Health and Nutrition Examination Survey 2005–2006
  7. Association between serum uric acid and non-alcoholic fatty liver disease in Korean adults
  8. Plasma osteopontin concentrations in preeclampsia – is there an association with endothelial injury?
  9. Determination of globotriaosylceramide in plasma and urine by mass spectrometry
  10. Effect of inflammation induced by prolonged exercise on circulating erythroid progenitors and markers of erythropoiesis
  11. The Beckman DxI 800 prolactin assay demonstrates superior specificity for monomeric prolactin
  12. Stability of cerebrospinal fluid/serum glucose ratio and cerebrospinal fluid lactate concentrations over 24 h: analysis of repeated measurements
  13. O-β-N-acetyl-D-glucosaminidase in erythrocytes of Italian air force acrobatic pilots
  14. Validation and Outcome Studies
  15. Experimental validation of specificity of the squamous cell carcinoma antigen-immunoglobulin M (SCCA-IgM) assay in patients with cirrhosis
  16. Performance analysis of the ARCHITECT anti-cyclic citrullinated peptide antibody in the diagnosis of rheumatoid arthritis
  17. Reference Values and Biological Variations
  18. Applicability of common reference intervals for serum creatinine concentrations to the Croatian population
  19. Laboratory reference intervals during pregnancy, delivery and the early postpartum period
  20. Determination of serum holotranscobalamin concentrations with the AxSYM active B12 assay: cut-off point evaluation in the clinical laboratory
  21. Definition of reference ranges for the platelet distribution width (PDW): a local need
  22. Cancer Diagnostics
  23. Mean leukocyte telomere length and risk of incident colorectal carcinoma in women: a prospective, nested case-control study
  24. Heat shock protein 27 is over-expressed in tumor tissues and increased in sera of patients with gastric adenocarcinoma
  25. Soluble mesothelin related peptides (SMRP) and osteopontin as protein biomarkers for malignant mesothelioma: analytical validation of ELISA based assays and characterization at mRNA and protein levels
  26. A novel sensitive immunoassay by nucleic acid barcode dot and its application in the detection of prostate-specific antigen
  27. Prostate cancer screening: clinical impact of WHO calibration of Beckman Coulter Access® prostate-specific antigen assays
  28. Infectious Diseases
  29. Use of flow cytometry (Sysmex® UF-100) to screen for positive urine cultures: in search for the ideal cut-off
  30. Letters to the Editor
  31. Improving laboratory efficiencies through significant time reduction in the preanalytical phase
  32. Comparison of the Vitek 2 system with the CLSI broth microdilution, disk diffusion, and sterol quantitation methods for determining fluconazole susceptibility against Candida spp.
Downloaded on 8.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2010.033/pdf
Scroll to top button