Home Regression-Based Reference Limits for Urinary Amino Acids in a Pediatric Population
Article
Licensed
Unlicensed Requires Authentication

Regression-Based Reference Limits for Urinary Amino Acids in a Pediatric Population

  • Rafael Venta , Belén Prieto and Francisco V. Alvarez
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 40 Issue 4

Abstract

Age-related variation of the urinary excretion of amino acids has been widely reported. Instead of the conventional reference intervals, continuous reference limits might be a more practical approach during periods of rapid changes such as infancy or childhood. Regression-based reference limits have been produced for the urinary excretion of 23 amino acids analyzed in 148 healthy individuals from 0 to 12 years of age. Urinary excretion was modeled as a function of age by two parametric procedures: the polynomial and the piecewise linear regression methods. Likewise, age-specific standard deviation was estimated by the regression of the absolute values of the residuals on age. Residual analysis was employed to select the best-fitting model and the 95% reference limits, and their 95% confidence intervals were calculated and plotted against the raw data. The urinary excretion of 19 amino acids decreased rapidly during the first year of life with a further slow decline thereafter. These amino acids fit better the piecewise model. The other four amino acids displayed a steady decrease in the urinary excretion from birth to puberty, and the excretion patterns fit better the quadratic or linear model. Fifteen amino acids showed a significant change in standard deviation with age. Regression-based reference limits differed consistently from conventional limits (<3 years) and narrower confidence intervals were obtained throughout the entire period studied. Avoiding partitioning gave rise to smoothly changing limits. Therefore, such alternative way of presenting amino acid reference limits may facilitate the follow-up of patients with inborn errors of amino acid metabolism.

:
Published Online: 2005-06-01
Published in Print: 2002-04-24

Copyright © 2002 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. Fecal Elastase-1 as a Test for Pancreatic Function: a Review
  2. α2-Macroglobulin Deletion Polymorphism and Plasma Levels in Late Onset Alzheimer's Disease
  3. High-Speed Detection of the Two Common Paraoxonase Polymorphisms Leu55 → Met and Gln192 → Arg by Real-Time Fluorescence PCR and Melting Curves
  4. Rapid Detection of Polymorphisms of the Nitric Oxide Cascade
  5. Salivary Electrolyte Concentrations Are Associated with Cystic Fibrosis Transmembrane Regulator Genotypes
  6. Granulocyte-Colony Stimulating Factor (G-CSF) and Macrophage-Colony Stimulating Factor (M-CSF) in Colorectal Cancer Patients
  7. Sialic Acid, Intercellular Adhesion Molecule-1 and Rheumatoid Arthritis: a Study on the Erythrocyte Membrane
  8. Determination of Organochlorine Pesticide Residues in the Blood of Healthy Individuals
  9. Reference Values for a Heterogeneous Ferritin Assay and Traceability to the 3rd International Recombinant Standard for Ferritin (NIBSC Code 94/572)
  10. The Circulating Levels of Cardiac Natriuretic Hormones in Healthy Adults: Effects of Age and Sex
  11. Plasma Free Amino Acids in Taiwan Chinese: the Effect of Age
  12. Regression-Based Reference Limits for Urinary Amino Acids in a Pediatric Population
  13. Evaluation of Uncertainty of Measurement in Routine Clinical Chemistry - Applications to Determination of the Substance Concentration of Calcium and Glucose in Serum
  14. Comparison of Quick and Owren Prothrombin Time with Regard to the Harmonisation of the International Normalised Ratio (INR) System
  15. The Accuracy of Calculated Base Excess in Blood
  16. Aspects of the Development of Clinical Chemistry and Laboratory Medicine in the former East Germany
  17. University Degree in Clinical Laboratory Sciences
  18. Process Control Reduces the Laboratory Turnaround Time
  19. Who Needs Two Different Citrate Concentrations in Sample Tubes Used for Coagulation Tests?
  20. Quantifying the Capability of Detection of Measurement Procedures in Clinical Laboratory Sciences
  21. Yet another Example of Lack of Laboratory Expertise in Certain Biomedical Publications
  22. Counterimmunoelectrophoresis: Fast, Easy and Cost-effective Method for the Detection of Autoantibodies to Intracellular Antigens
  23. Meetings and Awards
Downloaded on 11.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2002.062/pdf
Scroll to top button