Reference Values for a Heterogeneous Ferritin Assay and Traceability to the 3rd International Recombinant Standard for Ferritin (NIBSC Code 94/572)
-
Ahmad Hamwi
Abstract
Reference values for Ferritin FlexTM on the Dimension RxL analyzer calibrated against the 3rd International Standard for Ferritin (recombinant) and N-Latex Ferritin ® on the BNA II nephelometer calibrated against the 2nd International Standard for Ferritin (spleen) both from Dade Behring (Marburg, Germany) were established (77 men and 182 women). Exclusion criteria were iron deficiency or iron deficiency anemia, inflammation, liver disease, malignancy, and other hematological or chronic disorders. The reference values (5.0th–95th percentiles) were as follow: for N-Latex Ferritin® –men, 12–399 μg/l; women <50 years, 11–102 μg/l and women ≥50 years, 17–219 μg/l; for Ferritin FlexTM –men, 14–415 μg/l; women <50 years, 11–111 μg/l and women ≥50 years, 22–224 μg/l. Both assays correlated very closely with each other (r=0.993). The linearity was acceptable down to 2 μg/l for the Ferritin FlexTM method, but only down to 15 μg/l for the N-Latex Ferritin® assay. The mean recovery of the 3rd International Standard by N-Latex Ferritin® and Ferritin FlexTM was comparable (~80%). We conclude that the new Ferritin FlexTM assay, which is based on the new 3rd International Standard, should be used for ferritin measurement in the routine medical laboratories in the future.
Copyright © 2002 by Walter de Gruyter GmbH & Co. KG
Articles in the same Issue
- Fecal Elastase-1 as a Test for Pancreatic Function: a Review
- α2-Macroglobulin Deletion Polymorphism and Plasma Levels in Late Onset Alzheimer's Disease
- High-Speed Detection of the Two Common Paraoxonase Polymorphisms Leu55 → Met and Gln192 → Arg by Real-Time Fluorescence PCR and Melting Curves
- Rapid Detection of Polymorphisms of the Nitric Oxide Cascade
- Salivary Electrolyte Concentrations Are Associated with Cystic Fibrosis Transmembrane Regulator Genotypes
- Granulocyte-Colony Stimulating Factor (G-CSF) and Macrophage-Colony Stimulating Factor (M-CSF) in Colorectal Cancer Patients
- Sialic Acid, Intercellular Adhesion Molecule-1 and Rheumatoid Arthritis: a Study on the Erythrocyte Membrane
- Determination of Organochlorine Pesticide Residues in the Blood of Healthy Individuals
- Reference Values for a Heterogeneous Ferritin Assay and Traceability to the 3rd International Recombinant Standard for Ferritin (NIBSC Code 94/572)
- The Circulating Levels of Cardiac Natriuretic Hormones in Healthy Adults: Effects of Age and Sex
- Plasma Free Amino Acids in Taiwan Chinese: the Effect of Age
- Regression-Based Reference Limits for Urinary Amino Acids in a Pediatric Population
- Evaluation of Uncertainty of Measurement in Routine Clinical Chemistry - Applications to Determination of the Substance Concentration of Calcium and Glucose in Serum
- Comparison of Quick and Owren Prothrombin Time with Regard to the Harmonisation of the International Normalised Ratio (INR) System
- The Accuracy of Calculated Base Excess in Blood
- Aspects of the Development of Clinical Chemistry and Laboratory Medicine in the former East Germany
- University Degree in Clinical Laboratory Sciences
- Process Control Reduces the Laboratory Turnaround Time
- Who Needs Two Different Citrate Concentrations in Sample Tubes Used for Coagulation Tests?
- Quantifying the Capability of Detection of Measurement Procedures in Clinical Laboratory Sciences
- Yet another Example of Lack of Laboratory Expertise in Certain Biomedical Publications
- Counterimmunoelectrophoresis: Fast, Easy and Cost-effective Method for the Detection of Autoantibodies to Intracellular Antigens
- Meetings and Awards
Articles in the same Issue
- Fecal Elastase-1 as a Test for Pancreatic Function: a Review
- α2-Macroglobulin Deletion Polymorphism and Plasma Levels in Late Onset Alzheimer's Disease
- High-Speed Detection of the Two Common Paraoxonase Polymorphisms Leu55 → Met and Gln192 → Arg by Real-Time Fluorescence PCR and Melting Curves
- Rapid Detection of Polymorphisms of the Nitric Oxide Cascade
- Salivary Electrolyte Concentrations Are Associated with Cystic Fibrosis Transmembrane Regulator Genotypes
- Granulocyte-Colony Stimulating Factor (G-CSF) and Macrophage-Colony Stimulating Factor (M-CSF) in Colorectal Cancer Patients
- Sialic Acid, Intercellular Adhesion Molecule-1 and Rheumatoid Arthritis: a Study on the Erythrocyte Membrane
- Determination of Organochlorine Pesticide Residues in the Blood of Healthy Individuals
- Reference Values for a Heterogeneous Ferritin Assay and Traceability to the 3rd International Recombinant Standard for Ferritin (NIBSC Code 94/572)
- The Circulating Levels of Cardiac Natriuretic Hormones in Healthy Adults: Effects of Age and Sex
- Plasma Free Amino Acids in Taiwan Chinese: the Effect of Age
- Regression-Based Reference Limits for Urinary Amino Acids in a Pediatric Population
- Evaluation of Uncertainty of Measurement in Routine Clinical Chemistry - Applications to Determination of the Substance Concentration of Calcium and Glucose in Serum
- Comparison of Quick and Owren Prothrombin Time with Regard to the Harmonisation of the International Normalised Ratio (INR) System
- The Accuracy of Calculated Base Excess in Blood
- Aspects of the Development of Clinical Chemistry and Laboratory Medicine in the former East Germany
- University Degree in Clinical Laboratory Sciences
- Process Control Reduces the Laboratory Turnaround Time
- Who Needs Two Different Citrate Concentrations in Sample Tubes Used for Coagulation Tests?
- Quantifying the Capability of Detection of Measurement Procedures in Clinical Laboratory Sciences
- Yet another Example of Lack of Laboratory Expertise in Certain Biomedical Publications
- Counterimmunoelectrophoresis: Fast, Easy and Cost-effective Method for the Detection of Autoantibodies to Intracellular Antigens
- Meetings and Awards